1. SPECIFICATIONS
POWER SUPPLY :- 220/240volts AC
MONITOR :- Hantarex 28" Polo Colour Monitor with auto degauss.
DIMENSIONS :- 790(w) x 1200(d) x 2080(h)
ACCESSORIES :- Keys: (Cash Door) ................. 2
(Coin Door) .................. 2
(Back Door).................. 2
IEC Mains Lead ............................... 1
Operators Manual ............................ 1
Monitor Manual ................................ 1
1P - Punch Button 2
1P - Punch Button 1
1P - 8way Joystick
1P - Kick Button 1
1P - Kick Button 2
2P - Punch Button 1
2P - 8way Joystick
2P - Punch Button 2
2P - Kick Button 2
2P - Kick Button 1
Page 1
2. PRECAUTIONS
2-1 Cautions When Installing.
This game is designed for indoor use only. The game must not be installed
outdoors or
under the following conditions:­a. In areas directly exposed to sunlight, high humidity, direct water contact,
dust, high heat or extreme cold.
b. In locations that would present an obstacle in the case of an emergency,
i.e. near fire equipment or emergency exits.
c. On an unstable surface or subject to floor vibration.
2-2 Cautions when Handling.
a. AC power must always be turned OFF, and the game disconnected, before
replacing any parts or connecting/disconnecting connectors.
b. When unplugging the game from an electrical outlet, always grasp the
plug, not the mains lead. c. The machine must be earthed with a securely connected earthed plug. d. Care must be taken at all times to avoid electric shock when inspecting or
adjusting the game.
2-3 Cautions when Transporting.
a. Do not subject the game to physical shock when transporting or moving it. b. Always return the levellers to the UP position before moving the machine. c. Take care not to rope any moulded (plastic) parts when transporting.
2-4 Cautions when handling the PCB.
a. Never test the PCB for continuity with a multimeter or similar device. The
PCB contains sensitive devices which could be damaged or even
destroyed by the internal voltage of such test equipment. b. Foreign matter or dust on the PCB may cause failure. Turn off the power
and clean the PCB with a dry soft brush. c. When transporting the PCB ensure adequate packing protection to prevent
damage.
Page 3
3. ADJUSTMENTS
3-1 Turning on the Power
After installing the machine, turn on the power. The power switch is located above the mains inlet on the rear of the cabinet.
3-2 Switches for Adjustment
Open the coin door to find the switches for adjustments, located on the service bracket.
1. Service Switch Press this switch to obtain game credits without incrementing the coin
counter.
2. Test Switch Slide this switch "ON" to enter test mode.
Test mode allows game testing and the changing of game settings.
(See "3-4 Test Mode" on page 5)
There are two DIP switches located on the PCB. Switch 1 when set ON will enter the game into test mode. Always ensure this switch is set to OFF and use the test switch on the service bracket for testing the machine. Switch 2 when set ON will freeze the screen.
3-3 Volume Adjust
The volume control is located on the PCB. Turn the control to increase or
decrease the