PA
214
PA-RELAYS
THE SLIM POWER RELAY
mm inch
20
.787
5
.197
12.5
.492
FEATURES
• Slim size (width 5 mm .197 inch, height 12.5 mm .492 inch) permits higher density
mounting
• Wide switching capacity: Control from 100 µ A 100 mV to 5 A 250 V AC, 30 V DC
• High sensitivity: 120 mW (Nominal) (5 to 18 V DC type)
• High surge voltage (4000 V) and high breakdown voltage (2000 V)
• Shock & vibration resistance (functional): Min. 147m/s
2
{15 G}
• SIL (single in line) terminal layout
• Reinforced according to IEC1131-2 (TÜV)
SPECIFICATIONS
(at 20 ° C 68 ° F)
Contacts
Coil (at 25 ° C 77 ° F, 50% R.H.)
Remarks
*
Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Intial breakdown voltage" section
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
6
Half-wave pulse of sine wave: 6ms
*
7
Detection time: 10 µ s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics
Arrangement 1a
Contact material Gold-clad silver alloy
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 m Ω
Rating
(resistive)
Nominal switching capacity
5 A 250 V AC, 5 A 30 V DC
Maximum switching power
750 VA, 90 W
Maximum switching voltage
250 V AC, 110 V DC
Max. switching current
5 A
Min. switching capacity
100 µ A, 100 mV DC
Expected life
(min.
operations)
Mechanical 2 × 10
7
Electrical (at 20 cpm)
3 A 250 V AC, 3 A 30 V DC, 10
5
5 A 250 V AC, 5 A 30 V DC, 5 × 10
4
Nominal operating
power
5 to 18 V DC 120 mW
24 V DC 180 mW
Max. operating speed 20 cpm at rated load
Initial insulation resistance*
1
Min. 1,000 M Ω at 500 V DC
Initial breakdown
voltage*
2
Between open contacts 1,000 Vrms
Between contacts and coil
2,000 Vrms
Surge voltage between contacts and
coil*
3
4,000 V
Operate time*
4
(at nominal voltage) Approx. 6 ms
Release time (without diode)*
4
(at nominal voltage)
Approx. 3 ms
Temperature rise
Max. 45 ° C with nominal coil voltage across
coil and at nominal switching capacity
Shock resistance
Functional*
5
Min. 147 m/s
2
{15 G}
Destructive*
6
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
7
Min. 147 m/s
2
{15 G}, 10 to 55 Hz
at double amplitude of 2.5 mm
Destructive
Min. 205.8 m/s
2
{21 G}, 10 to 55 Hz
at double amplitude of 3.5 mm
Conditions for operation,
transport and storage*
8
(Not freezing and condensing at low temperature)
Ambient
temp.
–40 ° C to +70 ° C –40 ° F to +158 ° F
Humidity 5 to 85%R.H.
Unit weight Approx. 3 g .15 oz
TYPICAL APPLICATIONS
• Interface relays for programmable controllers
• Output relays for measuring equipment, timers, counters and
temperature controllers
• Industrial equipment, office equipment
ORDERING INFORMATION
Note: Standard packing: Tube: 25 pcs.; Case: 1,000 pcs.
UL/CSA, TÜV approved type is standard.
Ex. PA
1a 12V
Contact arrangement
1a: 1 Form A
Coil voltage (DC)
5, 6, 9, 12, 18, 24V
TYPES AND COIL DATA
(at 20 ° C 68 ° F)
*1 Pulse driving
Part No.
Nominal
voltage,
V DC
Pick-up
voltage,*
V DC (max.)
Drop-out
voltage,*
V DC (min.)
Nominal opera-
ting current,
mA ( ± 10%)
Nominal
operating power,
mW
Coil
resistance,
Ω ( ±
10%)
Max. allowable
voltage,
V DC
PA1a-5VV 5 3.5 0.25 24 120 208 6
PA1a-6VV 6 4.2 0.3 20 120 300 7.2
PA1a-9VV 9 6.3 0.45 13.3 120 675 10.8
PA1a-12V 12 8.4 0.6 10 120 1,200 14.4
PA1a-18V 18 12.6 0.9 6.7 120 2,700 21.6
PA1a-24V 24 16.8 1.2 7.5 180 3,200 28.8