NAIS LKS1aF-9V, LKS1aF-5V, LKS1aF-24V Datasheet

Contact arrangement Protective construction Coil voltage(DC)
1a: 1 Form A F: Flux-resistant type 5, 9, 12, 24V
Ex. LKS 1a F 12V
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 6 V, 18 V DC types are also available. Please consult us for details.
VDE
LK-S
FEATURES
1. High sensitivity: 250mW
The power-saving rela y is highly sensitive at the nominal operating power of 250 mW (530 mW power consumption on LK relays).
2. High insulation resistance between contact and coil
1) Creepage distance and clearances between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
2) Surge withstand voltage between con­tact and coil: 10,000 V or more
24.0
.945
11.0
.433
25.0
.984
mm inch
SPECIFICATIONS
Contact
Arrangement 1 Form A Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) Contact material Silver alloy
Nominal switching capacity 5 A 277 V AC
Rating (resistive load)
Expected life (min. operations)
Max. switching power 1,385 V A Max. switching voltage 277 V AC Max. switching current 5 A (AC) Mechanical (at 180 cpm) 10 Electrical (at 20 cpm)
(at rated load)
Coil
Nominal operating power 250 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
1
*
Measurement at same location as "Initial breakdown voltage" section.
2
Detection current: 10mA
*
3
*
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
4
Excluding contact bounce time.
*
5
*
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
6
Half-wave pulse of sine wave: 6 ms
*
7
*
Detection time: 10 µ s
8
Refer to 5. Conditions for operation, transport and storage mentioned in
*
AMBIENT ENVIRONMENT (Page 24).
Max. 100 m Ω
6
5
10
LK-S RELAYS
3. High noise immunity realized by the card separation structure between contact and coil
4. Popular terminal pitch in AV equip­ment field
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the v arious safety stan­dards
UL/CSA, VDE, TÜV and SEMKO SEV approved
Characteristics
Max. operating speed 20 cpm (at rated load) Initial insulation resistance*
Between open
2
Initial * breakdown voltage
Initial surge voltage between contact and coil*
Operate time* Release time (without diode)*
(at nominal voltage)
Temperature rise (at 70 ° C)
Shock resistance
Vibration resistance
Conditions for operation, transport and storage* (Not freezing and con­densing at low tempera­ture)
Unit weight Approx. 12 g .42 oz
contacts Between contact and
coil
3
4
(at nominal voltage) Approx. 7 ms (at 20 ° C 68 ° F)
1
4
Functional* Destructive*
Functional*
Destructive
Ambient temp.
8
Humidity 5 to 85% R.H. Air
pressure
Min. 1,000 M Ω (at 500 V DC)
1,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Approx. 2 ms (at 20 ° C 68 ° F) Max. 35 ° C with nominal coil
voltage and at 5 A contact carrying current (resistance method)
5
Min. 200 m/s
6
Min. 1,000 m/s
7
at double amplitude of 1.5mm
at double amplitude of 1.5mm
10 to 55Hz
10 to 55Hz
–40 ° C to +70 ° C
–40 ° F to +158 ° F
86 to 106 kPa
2
{approx. 20 G}
2
{approx. 100 G}
TYPICAL
ORDERING INFORMATION
APPLICATIONS
• Audio visual equipment
• Office equipment
• Home appliances
53
2-0.9 dia
2-.035 dia
2-1.3 dia
2-.051 dia
16.5
.650
7.5
.295
20.0
.787
Ω ( ±
±
±
LK-S
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Pick-up
voltage,
V DC (max.)
(Initial)
Part No.
Nominal
voltage,
V DC
LKS1aF-5V 5 3.5 0.5 100 50 250 6.5 LKS1aF-9V 9 6.3 0.9 324 27.8 250 11.7 LKS1aF-12V 12 8.4 1.2 576 20.8 250 15.6 LKS1aF-24V 24 16.8 2.4 2,304 10.4 250 31.2
DIMENSIONS
Drop-out
voltage,
V DC (min.)
(Initial)
Max. 25.0
.984
0.5
.020
Coil resistance,
10%)
Nominal
operating
current,
mA ( ± 10%)
Nominal
operating power ,
mW
V DC (at 20°C 68°F)
PC board pattern (Bottom view)
Maximum
allowable
voltage,
mm inch
4
0.4
.016
1.0
.039
.157
Dimension: General tolerance
7.5
.295
Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: ± 0.2 ± .008 Min. 3mm .118 inch:
0.5 dia.
.020 dia.
1.65
.065
0.3
.012
Max. 24.0
.945
16.5
.650
20.0
.787
REFERENCE DATA
1. Max. switching power (AC resistive load) 2. Coil temperature rise
100
10
5
Contact current, A
1
0 10 100
Contact voltage, V
Sample: LKS1aF-12V, 6 pcs. Point measured: coil inside Contact current: 0 A, 5A
30
25
20
15
Temperature rise, °C
10
5
0
800
Coil applied voltage, %V
Max. 11.0
.433
100 120
20°C 5A 20°C 0A
70°C 5A 70°C 0A
Tolerance: ± 0.1 ± .004
Schematic (Bottom view)
0.1 ± .004
0.3 ± .012
3. Ambient temperature characteristics and coil applied voltage
Contact current: 5 A
500
400
300
200
Coil applied voltage, %V
100
Allowable ambient temperatures against % coil voltages (max. inside the coil tem­ perature set as 115°C 239°F)
0
0 1020304050607080
Pick-up voltage
Ambient temperature, °C
Cold start
4. Life curve
Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: Room temperature
100
250V AC resistive load
12345
Contact current, A
4
10
Life, ×10
1
0
54
Loading...
+ 1 hidden pages