NAIS LKP1aF-24V, LKP1aF-12V Datasheet

LK-P
56
LK-P RELAYS
10 A Slim Power Relay
mm inch
25.0
.984
24.0
.945
11.0
.433
FEATURES
1. High switching capacity: 10 A 277V A C
2. High insulation resistance between contact and coil
1) Creepage distance and clearances between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
2) Surge withstand voltage between contact and coil: 10,000 V or more
3. High noise immunity realized by the card separation structure between con­tact and coil
4. Popular terminal pitch in AV equip­ment field
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the various safety stan­dards
UL/CSA, VDE, TÜV and SEMKO, SEV approved
SPECIFICATIONS
Contact
Coil
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µ s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
Characteristics
Arrangement 1 Form A Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 100 m Ω
Contact material Silver alloy
Rating (resistive load)
Nominal switching capacity
10 A 277 V AC, 5 A 30V DC
Max. switching power 2,770 V A, 150W Max. switching
voltage
277 V AC, 30 V DC
Max. switching current
10 A (AC), 5A (DC)
Expected life (min. operations)
Mechanical (at 180 cpm)
2 × 10
6
Electrical (at 20 cpm) (at rated load)
10
5
Nominal operating power 530 mW
Max. operating speed 20 cpm (at rated load) Initial insulation resistance*
1
Min. 1,000 M Ω (at 500 V DC)
Initial *
2
breakdown voltage
Between open contacts
1,000 Vrms for 1 min.
Between contact and coil
4,000 Vrms for 1 min.
Initial surge voltage between contact and coil*
3
Min. 10,000 V
Operate time*
4
(at nominal voltage) Approx. 7 ms (at 20 ° C 68 ° F)
Release time (without diode)*
4
(at nominal voltage)
Approx. 2 ms (at 20 ° C 68 ° F)
Temperature rise (at 70 ° C)
Max. 45 ° C with nominal coil voltage and at 10 A contact carrying current (resistance method)
Shock resistance
Functional*
5
Min. 200 m/s
2
{approx. 20 G}
Destructive*
6
Min. 1,000 m/s
2
{approx. 100 G}
Vibration resistance
Functional*
7
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 1.5mm
Conditions for operation, transport and storage*
8
(Not freezing and con­densing at low tempera­ture)
Ambient temp.
–40 ° C to +70 ° C
–40 ° F to +158 ° F
Humidity 5 to 85% R.H. Air
pressure
86 to 106 kPa
Unit weight Approx. 12 g .42 oz
TYPICAL APPLICATIONS
• Audio visual equipment TVs, VTRs
• Office equipment LBP, CRT
• Home appliances Refrigerator, Air conditioner
ORDERING INFORMATION
Contact arrangement Protective construction Coil voltage(DC)
1a: 1 Form A
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 5 V, 9 V, 18 V DC types are also available. Please consult us for details.
F: Flux-resistant type 12, 24V
Ex. LKP 1a F 12V
VDE
LK-P
57
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Part No.
Nominal
voltage,
V DC
Pick-up voltage,
V DC (max.)
(Initial)
Drop-out
voltage,
V DC (min.)
(Initial)
Coil resistance,
Ω ( ±
10%)
Nominal
operating
current,
mA ( ± 10%)
Nominal
operating power ,
mW
Maximum
allowable
voltage,
V DC (at 20°C 68°F) LKP1aF-12V 12 8.4 1.2 272 44.2 530 15.6 LKP1aF-24V 24 16.8 2.4 1,087 22.1 530 31.2
DIMENSIONS
mm inch
4
.157
0.5
.020
1.65
.065
Max. 25.0
.984
Max. 11.0
.433
0.3
.012
0.5 dia.
.020 dia.
20.0
.787
16.5
.650
0.4
.016
Max. 24.0
.945
7.5
.295
1.0
.039
Dimension:
General tolerance
Max. 1mm .039 inch:
±
0.1 ± .004 1 to 3mm .039 to .118 inch: ± 0.2 ± .008 Min. 3mm .118 inch:
±
0.3 ± .012
PC board pattern (Bottom view)
Tolerance: ± 0.1 ± .004
Schematic (Bottom view)
2-0.9 dia
2-.035 dia
2-1.3 dia
2-.051 dia
16.5
.650
7.5
.295
20.0
.787
REFERENCE DATA
1. Max. switching power 2. Coil temperature rise
Sample: LKP1aF-12V, 6 pcs. Point measured: coil inside Contact current: 5 A, 10 A
3. Ambient temperature characteristics and coil applied voltage
Contact current: 10 A
100
10
1
0 10 100
Contact voltage, V
Contact current, A
1000
20
60 55 50
40 35 30 25
45
120
20°C 10A 20°C 5A
70°C 10A 70°C 5A
Temperature rise, °C
Coil applied voltage, %V
20
220
180
140
100
60
0 1020304050607080
Ambient temperature, °C
Allowable ambient temperatures against % coil voltages (max. inside the coil tem­ perature set as 115°C 239°F)
Pick-up voltage
Coil applied voltage, %V
Cold start
4. Life curve
Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: room temperature
100
10
1
2046810
250V AC resistive load
Contact current, A
Life, ×10