RELAYS
10 A Slim Power Relay
mm inch
25.0
.984
24.0
.945
11.0
.433
FEATURES
1. High switching capacity: 10 A 277V A C
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
2) Surge withstand voltage between contact
and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between contact and coil
4. Popular terminal pitch in AV equipment field
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the various safety standards
UL/CSA, VDE, TÜV and SEMKO, SEV
approved
SPECIFICATIONS
Contact
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µ s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Characteristics
Arrangement 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 100 m Ω
Contact material Silver alloy
Rating
(resistive load)
Nominal switching
capacity
10 A 277 V AC, 5 A 30V DC
Max. switching power 2,770 V A, 150W
Max. switching
voltage
277 V AC, 30 V DC
Max. switching
current
10 A (AC), 5A (DC)
Expected life
(min. operations)
Mechanical
(at 180 cpm)
2 × 10
6
Electrical (at 20 cpm)
(at rated load)
10
5
Nominal operating power 530 mW
Max. operating speed 20 cpm (at rated load)
Initial insulation resistance*
1
Min. 1,000 M Ω (at 500 V DC)
Initial *
2
breakdown
voltage
Between open
contacts
1,000 Vrms for 1 min.
Between contact and
coil
4,000 Vrms for 1 min.
Initial surge voltage between contact
and coil*
3
Min. 10,000 V
Operate time*
4
(at nominal voltage) Approx. 7 ms (at 20 ° C 68 ° F)
Release time (without diode)*
4
(at nominal voltage)
Approx. 2 ms (at 20 ° C 68 ° F)
Temperature rise (at 70 ° C)
Max. 45 ° C with nominal coil
voltage and at 10 A contact
carrying current
(resistance method)
Shock resistance
Functional*
5
Min. 200 m/s
2
{approx. 20 G}
Destructive*
6
Min. 1,000 m/s
2
{approx. 100 G}
Vibration resistance
Functional*
7
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 1.5mm
Conditions for operation,
transport and storage*
8
(Not freezing and condensing at low temperature)
Ambient
temp.
–40 ° C to +70 ° C
–40 ° F to +158 ° F
Humidity 5 to 85% R.H.
Air
pressure
86 to 106 kPa
Unit weight Approx. 12 g .42 oz
TYPICAL
APPLICATIONS
• Audio visual equipment
TVs, VTRs
• Office equipment
LBP, CRT
• Home appliances
Refrigerator, Air conditioner
ORDERING INFORMATION