![](/html/24/241c/241ca3400bbf8282d3aa943a2cd37edaa6ec04c89086c3c8bee513e565be87bc/bg1.png)
Creepage distance and clearances in compliance with IEC65
Card
Partition wall
VDE
SLIM POWER RELAY WITH
HIGH INRUSH CURRENT
LK-RELAYS
CAPABILITY
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
24.0
.945
11.0
.433
25.0
.984
2) Surge withstand voltage between contact and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between
mm inch
contact and coil
4. Popular terminal pitch in AV equipment field
FEATURES
1. High inrush current capability
1) Operating load capability:
inrush 100 A, steady 5 A
2) UL/CSA, TV-5
COM
Coil
SPECIFICATIONS
Contact
Arrangement 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material Silver alloy
Nominal switching capacity 5 A 277 V AC, 5 A 30 V DC
Rating
(resistive
load)
Max. switching power 1,385 VA, 150 W
Max. switching voltage 277 V AC, 30 V DC
Max. switching current 5A (AC), 5 A (DC)
Expected
life (min.
ope.)
Mechanical (at 180 cpm) 2 × 10
Electrical (at 20 cpm)
(at rated load)
Coil
Nominal operating power 530 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
*
Detection current: 10mA
3
*
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
4
Excluding contact bounce time.
*
5
*
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
6
Half-wave pulse of sine wave: 6 ms
*
7
*
Detection time: 10 µ s
8
Refer to 5. Conditions for operation, transport and storage mentioned in
*
AMBIENT ENVIRONMENT (Page 24).
Max. 100 m Ω
6
5
10
N.O.
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the v arious safety stan-
7.5
dards
UL, CSA, VDE, TÜV, SEMKO, SEV, BSI
approved
16.5
.650
.787
mm inch
1
.039
.295
20
.039
1
Characteristics
Max. operating speed 20 cpm
Initial insulation resistance*
Initial
breakdown
voltage*
Initial surge voltage between contact and coil*
Operate time*
Between open contacts
Between contacts and coil
2
3
4
(at nominal voltage) Approx. 7 ms (at 20 ° C 68 ° F)
Release time (without diode)*
1
4
(at nominal voltage)
Temperature rise (at 70 ° C)
Shock
resistance
Vibration
resistance
Functional*
Destructive*
Functional*
Destructive
Conditions for operation,
transport and storage*
(Not freezing and condensing at low temperature)
5
6
7
Ambient temp.
8
Humidity 5 to 85%R.H.
Air pressure 86 to 106 kPa
Unit weight Approx. 12 g .42 oz
Min. 1,000 M Ω (at 500 V DC)
1,000 Vrms for 1 min
4,000 Vrms for 1 min
Min. 10,000 V
Approx. 2 ms (at 20 ° C 68 ° F)
Max. 35 ° C with nominal coil voltage
at 5A contact carrying current
(resistance method)
Min. 200 m/s
Min. 1,000 m/s
10 to 55 Hz
at double amplitude of 1.5 mm
10 to 55 Hz
at double amplitude of 1.5 mm
–40 to +70 ° C -40 to +158 ° F
2
2
TYPICAL APPLICATIONS
• AV equipment: TV’s, VTR’s, etc.
• OA equipment
• HA equipment
ORDERING INFORMATION
Ex. LK 1a F — 24V
Contact arrangement
1a: 1 Form A F: Flux-resistant type 5, 9, 12, 24 V
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
(Note) Standard packing Carton: 100 pcs. Case: 500 pcs.
Protective construction Coil voltage (DC)
59
![](/html/24/241c/241ca3400bbf8282d3aa943a2cd37edaa6ec04c89086c3c8bee513e565be87bc/bg2.png)
2-0.9 dia
2-.035 dia
2-1.3 dia
2-.051 dia
16.5
.650
7.5
.295
20.0
.787
Ω ( ±
±
±
LK
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Part No.
voltage,
V DC
LK1aF-5V 5 3.5 0.5 47 106.4 530 6.5
LK1aF-9V 9 6.3 0.9 153 58.8 530 11.7
LK1aF-12V 12 8.4 1.2 272 44.2 530 15.6
LK1aF-24V 24 16.8 2.4 1,087 22.1 530 31.2
DIMENSIONS
Nominal
Pick-up voltage
V DC (max.)
(Initial)
Drop-out voltage
V DC (min.)
(Initial)
0.5 dia.
.020 dia. .012
1.65
.065
Max. 24
0.3
.945
Coil resistance,
10%)
Max. 25
.984
0.5
.020
4
.157
0.4
.016
Nominal operat-
ing current, mA
( ± 10%)
Max. 11
.433
Nominal
Max. allowable
operating power ,
mW
V DC (at 20°C 68°F)
PC board pattern (Copper-side view)
Tolerance ± 0.1 ± .004
Schematic (Bottom view)
voltage,
mm inch
16.5
.650
Dimension : General tolerance
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch: ± 0.2 ± .008
Min. 3mm .118 inch:
0.1 ± .004
0.3 ± .012
20
.787
REFERENCE DATA
1. Max. switching power (AC resistive load) 2. Coil temperature rise
10
1
Contact current, A
0.1
0.1
1 10 100 1000
Contact voltage, V
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: room temperature
100
250V AC resistive load
102345
Contact current, A
60
4
10
Life, ×10
1
Sample: LK1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 5 A
50
Ambient temperature
30°C
40
30
Temperature rise, °C
20
10
0
5-1. Operate & release time (without diode)
Sample: LK1aF-12V, 20 pcs.
15
10
5
Operate & release time, ms
0
1
.039
7.5
.295
1
.039
Ambient temperature
70°C
120
110
100
90
80
Coil applied voltage, %V
Operate time
Release time
70 100 130
Coil applied voltage, %V
Max.
Min.
Max.
Min.
3. Ambient temperature characteristics
Contact current: 5 A
200
180
160
140
120
Coil applied voltage, %V
100
80
60
Allowable ambient temperatures
against % coil voltages
(max. inside the coil tem perature set as
115°C 239°F)
Pick-up voltage
20 30 40 50 60 70 80
10
Ambient temperature, °C
Cold start
5-2. Operate & release time (with diode)
Sample: LK1aF-12V, 20 pcs.
15
10
5
Operate & release time, ms
0
70 100 130
Coil applied voltage, %V
Operate time
Release time
Max.
Min.
Max.
Min.