SLIM POWER RELAY WITH HIGH INRUSH CURRENT
LK-RELAYS
2. High insulation resistance between contact and coil
1) Creepage distance and clearances between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
24.0
.945
11.0
.433
25.0
.984
2) Surge withstand voltage between con­tact and coil: 10,000 V or more
3. High noise immunity realized by the card separation structure between
mm inch
contact and coil
4. Popular terminal pitch in AV equip­ment field
FEATURES
1. High inrush current capability
1) Operating load capability: inrush 100 A, steady 5 A
2) UL/CSA, TV-5
COM
Coil
SPECIFICATIONS
Contact
Arrangement 1 Form A Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) Contact material Silver alloy
Nominal switching capacity 5 A 277 V AC, 5 A 30 V DC Rating (resistive load)
Max. switching power 1,385 VA, 150 W
Max. switching voltage 277 V AC, 30 V DC
Max. switching current 5A (AC), 5 A (DC) Expected
life (min. ope.)
Mechanical (at 180 cpm) 2 × 10
Electrical (at 20 cpm)
(at rated load)
Coil
Nominal operating power 530 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
*
Detection current: 10mA
3
*
Wave is standard shock voltage of ± 1.2 × 50 µ s according to JEC-212-1981
4
Excluding contact bounce time.
*
5
*
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
6
Half-wave pulse of sine wave: 6 ms
*
7
*
Detection time: 10 µ s
8
Refer to 5. Conditions for operation, transport and storage mentioned in
*
AMBIENT ENVIRONMENT (Page 24).
Max. 100 m Ω
6
5
10
N.O.
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the v arious safety stan-
7.5
dards
UL, CSA, VDE, TÜV, SEMKO, SEV, BSI approved
16.5
.650
.787
mm inch
1
.039
.295
20
.039
1
Characteristics
Max. operating speed 20 cpm Initial insulation resistance* Initial
breakdown voltage*
Initial surge voltage between con­tact and coil*
Operate time*
Between open contacts Between contacts and coil
2
3
4
(at nominal voltage) Approx. 7 ms (at 20 ° C 68 ° F)
Release time (without diode)*
1
4
(at nominal voltage)
Temperature rise (at 70 ° C)
Shock resistance
Vibration resistance
Functional* Destructive*
Functional*
Destructive
Conditions for operation, transport and storage* (Not freezing and condens­ing at low temperature)
5
6
7
Ambient temp.
8
Humidity 5 to 85%R.H. Air pressure 86 to 106 kPa
Unit weight Approx. 12 g .42 oz
Min. 1,000 M Ω (at 500 V DC)
1,000 Vrms for 1 min 4,000 Vrms for 1 min
Min. 10,000 V
Approx. 2 ms (at 20 ° C 68 ° F)
Max. 35 ° C with nominal coil voltage
at 5A contact carrying current
(resistance method)
Min. 200 m/s
Min. 1,000 m/s
10 to 55 Hz
at double amplitude of 1.5 mm
10 to 55 Hz
at double amplitude of 1.5 mm
–40 to +70 ° C -40 to +158 ° F
2
2
TYPICAL APPLICATIONS
• AV equipment: TV’s, VTR’s, etc.
• OA equipment
• HA equipment
ORDERING INFORMATION
Ex. LK 1a F 24V
Contact arrangement
1a: 1 Form A F: Flux-resistant type 5, 9, 12, 24 V
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. (Note) Standard packing Carton: 100 pcs. Case: 500 pcs.
Protective construction Coil voltage (DC)
59
2-0.9 dia
2-.035 dia
2-1.3 dia
2-.051 dia
16.5
.650
7.5
.295
20.0
.787
Ω ( ±
±
±
LK
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Part No.
voltage,
V DC LK1aF-5V 5 3.5 0.5 47 106.4 530 6.5 LK1aF-9V 9 6.3 0.9 153 58.8 530 11.7 LK1aF-12V 12 8.4 1.2 272 44.2 530 15.6 LK1aF-24V 24 16.8 2.4 1,087 22.1 530 31.2
DIMENSIONS
Nominal
Pick-up voltage
V DC (max.)
(Initial)
Drop-out voltage
V DC (min.)
(Initial)
0.5 dia.
.020 dia. .012
1.65
.065
Max. 24
0.3
.945
Coil resistance,
10%)
Max. 25
.984
0.5
.020
4
.157
0.4
.016
Nominal operat-
ing current, mA
( ± 10%)
Max. 11
.433
Nominal
Max. allowable
operating power ,
mW
V DC (at 20°C 68°F)
PC board pattern (Copper-side view)
Tolerance ± 0.1 ± .004
Schematic (Bottom view)
voltage,
mm inch
16.5
.650
Dimension : General tolerance Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: ± 0.2 ± .008 Min. 3mm .118 inch:
0.1 ± .004
0.3 ± .012
20
.787
REFERENCE DATA
1. Max. switching power (AC resistive load) 2. Coil temperature rise
10
1
Contact current, A
0.1
0.1
1 10 100 1000
Contact voltage, V
4. Life curve
Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: room temperature
100
250V AC resistive load
102345
Contact current, A
60
4
10
Life, ×10
1
Sample: LK1aF-12V, 6 pcs. Point measured: coil inside Contact current: 5 A
50
Ambient temperature 30°C
40
30
Temperature rise, °C
20
10
0
5-1. Operate & release time (without diode)
Sample: LK1aF-12V, 20 pcs.
15
10
5
Operate & release time, ms
0
1
.039
7.5
.295
1
.039
Ambient temperature 70°C
120
110
100
90
80
Coil applied voltage, %V
Operate time Release time
70 100 130
Coil applied voltage, %V
Max. Min.
Max. Min.
3. Ambient temperature characteristics
Contact current: 5 A
200
180
160
140
120
Coil applied voltage, %V
100
80
60
Allowable ambient temperatures against % coil voltages (max. inside the coil tem­ perature set as 115°C 239°F)
Pick-up voltage
20 30 40 50 60 70 80
10
Ambient temperature, °C
Cold start
5-2. Operate & release time (with diode)
Sample: LK1aF-12V, 20 pcs.
15
10
5
Operate & release time, ms
0
70 100 130
Coil applied voltage, %V
Operate time Release time
Max.
Min.
Max. Min.