ULTRA-MINIATURE
PC BOARD TYPE
POWER RELAY
mm inch
16
.630
16
.630
22
.866
FEATURES
• Ultra-miniature size with universal terminal footprint
• High contact capacity: 10 A
• Class B coil insulation type available
• TV-5 type available
1 Form A type → TV -5
1 Form C type → TV-5 (N.O. side only)
• VDE, TÜV also approved
• Sealed construction for automatic cleaning
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form A, 1 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Ω
Contact material Silver alloy
Rating
(resistive
load)
Nominal switching capacity
10 A 250 V AC
10 A 125 V AC
6 A 277 V AC
Max. switching power 2,500 VA
Max. switching voltage 250 V AC, 100 V DC
Max. switching current 10 A (AC), 5 A (DC)
Expected
life
(min.ope.)
Mechanical (at 180 cpm) 10
7
Electrical at 10 A 125 V AC,
6 A 277 V AC resistive
(at 20 cpm)
10
5
10 A 250 V AC resistive
(at 20 cpm)
5 × 104
(No contact only)
Nominal operating power 360 mW
Max. operating speed 20 cpm
Initial insulation resistance Min. 100 MΩ (at 500 V DC)
Initial
breakdown
voltage*
1
Between open contacts 750 Vrms for 1 min.
Between contacts and coil 1,500 Vrms for 1 min.
Operate time*
2
(at nominal voltage)
Approx. 10 ms
Release time(without diode)*2 (at nominal
voltage)
Approx. 10 ms
Temperature rise (at nominal voltage) Max. 35°C
Shock resistance
Functional*
3
Min. 98 m/s2 {10 G}
Destructive*
4
Min. 980 m/s2 {100 G}
Vibration
resistance
Functional*
5
Approx. 98 m/s2 {10 G},
10 to 55 Hz at double
amplitude of 1.6 mm
Destructive
Approx. 117.6 m/s2 {12 G},
10 to 55 Hz at double
amplitude of 2 mm
Conditions for operation,
transport and storage*
6
(Not freezing and condensing at low temperature)
Ambient
temp.*
7
–40°C to +85°C
–40°F to +185°F
Humidity 5 to 85% R.H.
Unit weight Approx.12 g .423 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1Detection current: 10mA
*
2
Excluding contact bounce time
*3Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
4
Half-wave pulse of sine wave: 6ms
*5Detection time: 10µs
*
6
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
*
7
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within the
maximum allowable voltage range.
TYPICAL APPLICATIONS
1. Home appliances
Air conditioner, heater, etc.
2. Automotive
Pow er-window , car antenna, door-lock,
etc.
3. Office machines
PPC, facsimile, etc.
4. Vending machines