COST SAVING SUBMINIATURE
HA-RELAYS
PC BOARD RELAYS
14.0
26.3
1.035
.551
16.9
.665
26.5
1.043
14.2
.559
17.7
.697
HAE Amber Relays
mm inch
SPECIFICATIONS
HA1 Standard type Contacts
Arrangement 1 Form C Contact material Silver-nickel Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) Rating
(resistive load)
Expected life (min. operations)
Max. switching power 750 VA, 90 W Max. switching voltage 250 V AC, 30 V DC Max. switching current 3 A Mechanical 10
Electrical (resistive)
3 A 250 V AC 10 3 A 30 V DC 5 × 10
Coil
Minimum operating power (AC) 0.58 VA, (DC) 230 mW Nominal operating power (AC) 0.9 VA, (DC) 360 mW
Characteristics
Maximum operating speed 20 cpm Initial insulation resistance*
(at 25 ° C, 50% R.H.) Initial
breakdown voltage*
Operate time*
Between open contacts 750 Vrms for 1 min.
2
Between contacts and coil 1,500 Vrms for 1 min.
3
(at nominal voltage)
(at 20 ° C) Release time (without diode)*
(at nominal voltage)(at 20 ° C)
Temperature rise (at 20 ° C)
Shock resistance
Vibration resistance
Conditions for operation, transport and storage* (Not freezing and con­densing at low tempera­ture)
Unit weight Approx. 15 g .53 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as "Intial breakdown voltage" section
*
2
*
Detection current: 10 mA
1
3
Min. 100 M Ω at 500 V DC
Max. (AC) 60 ° C, (DC) 40 ° C
with nominal coil voltage and
Functional 98 m/s Destructive 980 m/s
Functional
at double amplitude of 1mm
Destructive Ambient
4
temp. Humidity 5 to 85%R.H.
208
50 m Ω
7
5
5
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
at 3A switching current
2
{10G}
2
{100G}
10 to 55Hz
10 to 55Hz
at switching of 2mm
–40 ° C to +50 ° C
–40 ° F to +122 ° F
FEATURES
• Compact construction
• Sensitive - very low operating power
• Soldering flux inflow prevented by molded construction
• Contact capacity - 3 A 250 V AC, 30 V DC
• Simple mechanism for stable quality - only 9 pieceparts
• Amber sealed types available
HA1E Amber sealed type Contacts
Arrangement 1 Form C Contact material Gold-clad over silver-nickel Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) Rating
(resistive load)
Expected life (min. operations)
Max. switching power 500 VA, 90 W Max. switching voltage 250 V AC, 30 V DC Max. switching current 2 A AC, 3A DC Mechanical 10
Electrical (resistive)
2 A 250 V AC 10 3 A 30 V DC 2 × 10
Coil
Minimum operating power (AC) 0.58 VA, (DC) 230 mW Nominal operating power (AC) 0.9 VA, (DC) 360 mW
Characteristics
Maximum operating speed 20 cpm Initial insulation resistance*
(at 25 ° C, 50% R.H.) Initial
breakdown voltage*
Operate time*
Between open contacts 750 Vrms for 1 min.
2
Between contacts and coil 1,500 Vrms for 1 min.
3
(at nominal voltage)
(at 20 ° C) Release time (without diode)*
(at nominal voltage)(at 20 ° C)
Temperature rise (at 50 ° C)
Shock resistance
Vibration resistance
Conditions for operation, transport and storage* (Not freezing and con­densing at low tempera­ture)
Unit weight Approx. 15 g.53 oz
3
*
Excluding contact bounce time
4
Refer to 5. Conditions for operation, transport and storage mentioned in
*
AMBIENT ENVIRONMENT (Page 61).
1
3
Min. 100 M Ω at 500 V DC
Max. (AC) 60 ° C, (DC) 40 ° C
with nominal coil voltage and
Functional 98 m/s Destructive 980 m/s
4
Functional
Destructive Ambient
temp.
at double amplitude of 1mm
at double amplitude of 2mm
Humidity 5 to 85%R.H.
50 m Ω
7
5
5
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
at 3A switching current
2
{10G}
2
{100G}
10 to 55Hz
10 to 55Hz
–40 ° C to +50 ° C
–40 ° F to +122 ° F
6.5
.256
14.0
.551
2.54×7
.100×7
26.3
1.035
1.34
.053
5-1.2 dia.
5-.047 dia.
Relay outline
2.54×2
.100×2
5
1
2
4 3
6.5
.256
14.2
.559
2.54×7
.100×7
26.5
1.043
1.5
.059
5-1.2 dia.
5-.047 dia.
Relay outline
2.54×2
.100×2
Ω ( ±
HA
TYPICAL APPLICATIONS
Office machines, electrical home appli-
ORDERING INFORMATION
Ex.
HA 1 E DC6V
ances, load management equipment.
Contact arrangement
1: 1 Form C Nil: Dust cover type
Notes: 1. For UL/CSA recognized types, add suffix UL/CSA.
(Notes) 2. Standard packing Carton: 100 pcs., Case: 500 pcs. or 2,000 pcs.
Type classification Coil voltage
E: Amber sealed type
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Part No. Nominal voltage
HA1-AC6V HA1E-AC6V
HA1-AC12V HA1E-AC12V
HA1-AC24V HA1E-AC24V
HA1-AC48V HA1E-AC48V
HA1-AC115V HA1E-AC115V
12 V AC 9.6 V AC 2.4 V AC 76 0.9 VA 13.2 V AC
24 V AC 19.2 V AC 4.8 V AC 37 0.9 V A 26.4 V AC
48 V AC 38.4 V AC 9.6 V AC 19 0.9 V A 52.8 V AC
115 V AC 92.0 V AC 23.0 V AC 8 0.9 VA 126.5 V AC
HA1-DC5V HA1E-DC5V
HA1-DC6V HA1E-DC6V
HA1-DC9V HA1E-DC9V
HA1-DC12V HA1E-DC12V
HA1-DC24V HA1E-DC24V
12 V DC 9.6 V DC 1.2 V DC 30 360 mW 400 14.4 V DC
24 V DC 19.2 V DC 2.4 V DC 15 360 mW 1,600 28.8 V DC
Pick-up voltage,
(max.)
6 V AC 4.8 V AC 1.2 V AC 150 0.9 V A 6.6 V AC
5 V DC 4.0 V DC 0.5 V DC 72 360 mW 69 6.0 V DC
6 V DC 4.8 V DC 0.6 V DC 60 360 mW 100 7.2 V DC
9 V DC 7.2 V DC 0.9 V DC 40 360 mW 225 10.8 V DC
Drop-out
voltage,
(min.)
Note: The range of coil current — AC type: ± 15% at 60 Hz, DC type: ± 10% at 20 ° C 68°F coil temperature.
* Nominal operating
current, mA
Nominal
operating power
DC 5, 6, 9, 12, 24 V AC 6, 12, 24, 48, 115V
Coil resistance,
10%)
Maximum
allowable
voltage
DIMENSIONS
HA1
16.4
.646
4
.157
0.6 dia.
.024 dia.
.358
General tolerance: ± 0.5 ± .020
9.1
0.5
.020
.031 .051
0.8
1.3
4
.157
26.3
1.035
0.6 dia.
.024 dia.
19.1
.752
24.2
.953
6.5
.256
11.6
.457
.551
0.9 dia.
.035 dia.
mm inch
PC board pattern (Copper-side view)
HA1E
17.7
.697
3.2
.126
4.8
17
.669
.189
0.6 dia.
.024 dia.
9.0
3.9
14
.354
0.8
.031
1.5
.059
.154
26.6
1.047
0.6 dia.
.024 dia.
19.2
.756
24.3
.957
General tolerance: ± 0.5 ± .004
4.8
.189
0.5
.020
6.5
.256
0.9 dia.
.035 dia.
11.5
.453
14.2
.559
HA1
HA1E
Tolerance: ± 0.1 ± .004
Schematic (Bottom view)
21
5
43
209