SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form C × 2 (H bridge)
Contact material Silver alloy
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
100 m Ω
Contact voltage drop, max. 0.2V (at 10 A switching)
Rating
Nominal switching
capacity
N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC
Max. carrying current
35 A for 2 minutes,
25 A for 1 hour
(12 V, at 20 ° C68 ° F)
30 A for 2 minutes,
20 A for 1 hour
(12 V, at 85 ° C185 ° F)
Expected life
(min. operations)
Mechanical (at 120 cpm) Min. 10
7
Electrical
Resistive load Min. 10
5
*
1
Motor load
Min. 2 × 10
5
*
2
Min. 10
5
*
3
Nominal operating power 640 mW
Max. operating speed
(at nominal switching capacity)
6 cpm
Initial insulation resistance*
4
Min. 100 M Ω (at 500 V DC)
Initial breakdown
voltage*
5
Between open
contacts
500 Vrms for 1 min.
Between contacts
and coil
500 Vrms for 1 min.
Operate time*
6
(at nominal voltage)(at 20 ° C68 ° F)
Max. 10 ms (initial)
Release time (without diode)*
6
(at nominal voltage)(at 20 ° C68 ° F)
Max. 10 ms (initial)
Shock resistance
Functional*
7
Min. 100 m/s
2
{10G}
Destructive*
8
Min. 1,000 m/s
2
{100G}
Vibration resistance
Functional*
9
10 to 100 Hz,
Min. 44.1 m/s
2
{4.5G}
Destructive*
10
10 to 500 Hz,
Min. 44.1 m/s
2
{4.5G}
Conditions for operation, transport and
storage*
11
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–40 to +85 ° C
–40 to +185 ° F
Humidity 5 to 85% R.H.
Unit weight Approx. 12.5g.44 oz
Remarks
* Specifications will vary with foreigh standards certification ratings.
*
1
At nominal switching capacity, operating frequency: 1s ON, 9s OFF
*
2
N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating frequency: 0.5s ON, 9.5s OFF
*
3
At 20A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF
*
4
Measurement at same location as "Initial breakdown voltage " section
*
5
Detection current: 10mA
*
6
Excluding contact bounce time
*
7
Half-wave pulse of sine wave: 11ms; detection: 10 µ s
*
8
Half-wave pulse of sine wave: 6ms
*
9
Detection time: 10 µ s
*
10
Time of vibration for each direction;
X, Y direction: 2 hours
Z direction: 4 hours
*
11
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)