NAIS ARZ225C12, ARZ225C05, ARZ220M24, ARZ220M12, ARZ220M05 Datasheet

...
RZ(ARZ1,2)
1
RZ-CO AXIAL SWITCHES
TWO SERIES LINE-UP OF IMPEDANCE 50Ω AND 75
FEATURES
1. Two series line-up of impedance 50Ω and 75
2. Mechanical switch with superb high-frequency characteristics.
3. Low profile type package
TYPICAL APPLICATIONS
1. Cellular phone base stations (IMT-2000)
2. Digital broadcast equipment
3. Test measurement equipment
STANDARD PRODUCTS
Circuit arrangement Impedance Frequency Connector
50Ω series
DPDT bypass
50
to 2.5 GHz SMA
SP4T
75Ω series
SP4T with termination
75
to 1.5 GHz BNC-J
Transfer
CUSTOM PRODUCTS
RZ coaxial switches can be customized. From the point of view of pricing and deliv ery we recommend our standard products, ho w ever, you may contact us if you require a cir­cuit configuration that differs from the products above. Please understand that, depending on the conditions, we may not be able to customize in some cases.
RZ(ARZ1,2)
2
DPDT switch internal connection (bypass) type (50Ω, to 2.5 GHz)
(mm inch)
45.0
1.772
56.0
2.205
15.0
0.591
ORDERING INFORMATION
ARZEx. 2 2 0 M
RZ coaxial switches 22: DPDT 0: Failsafe (50) M: Bypass 05: 5
12: 12 24: 24
Product name Contact arrangement Operating function and impedance Added function Operating voltage, V DC
PRODUCT TYPES
Operating voltage (Vcc)
Part No.
Failsafe
5 V DC ARZ220M05 12 V DC ARZ220M12 24 V DC ARZ220M24
SPECIFICATIONS
1. Characteristics
High frequency characteristics (to 2.5 GHz, Impedance 50Ω) (Initial)
Impedance 50
Insertion loss Max. 1.0 dB Isolation Min. 60 dB V.S.W.R. Max. 1.5 Input power 20 W
Electrical characteristics
Operating voltage Vcc±5% Operate time 10 ms (excluding contact bounce time)
Expected life (min. operations)
Electrical 5 × 10
4
Ambient temperature
Operate 0°C to +50°C 32°F to +122°F Storage –10°C to +60°C +14°F to +140°F
Others Connector SMA
RZ(ARZ1,2)
3
REFERENCE DATA
1. High frequncy characteristics
• Insertion loss (Through and between terminal 1 to 3)
• Isolation (Between terminal 1 to 3)
• V .S .W .R. (Through and between terminal 1 to 3)
0.8
0.9
1.0
0
0.2
0.1
0.6
0.7
0.4
0.5
0.3
1GHz 3GHz2GHz
Frequency
Insertion loss, dB
Through
Between terminal 1 to 3
80 90
100
0
20
10
30
60
50
70
40
1GHz 3GHz2GHz
Frequency
Isolation, dB
1.1
1.0
1.5
1.2
1.4
1.3
1GHz 3GHz2GHz
Frequency
V.S.W.R.
Through
Between terminal 1 to 3
DIMENSIONS
mm inch
Equivalent circuit
Switching operation table
Note) Do not apply multiple control signals simultaneously.
7 .276
44 1.732
50 1.969
56 2.205
5
.197
14.9
.587
4-2.75 dia.
4-.108 dia.
30
1.181
43
12
+2+1
Control terminal +1 Control terminal +2
Control terminal –2Control terminal –1
45
1.772
22
.866
RF terminal path (SMA) Control terminal
3 to 4 (1, 2: no connection)
None
1 to 3 2 to 4
Control terminal +1, +2 → Vcc Control terminal –1, –2 → Gnd
Control terminal +1
Control terminal –1 Control terminal +2
Control terminal –2
RF terminal 4RF terminal 3
RF terminal 1 RF terminal 2