VDE
LD
1 Form A Slim Power Relay
FEATURES
20.3
.799
7.0
.276
15.0
.591
mm inch
1. Slim type: Width 7 mm .276 inch.
20.3(L) × 7.0(W) × 15.0(H) mm
.799(L) × .276(W) × .591(H) inch
2. Perfect for small load switching of
home appliances
5
10
switching operations possible with a
3A 250V AC resistive load.
3. Low operating power
Compact size, nominal operating power
as low as 200mW.
SPECIFICATIONS
Contact
Arrangement 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material Silver alloy
Nominal switching capacity
Rating
(resistive load)
Max. switching power
Max. switching voltage 277 V AC, 30 V DC
Max. switching current 3 A
Mechanical (at 180 cpm) 5 × 10
Expected life
(min.operations)
Electrical
(at 20 cpm)
(at rated load)
3A 125V AC,
3A 30V DC
3A 250V AC 10
Coil
Nominal operating power 200 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
*
Detection current: 10mA
3
Wave is standard shock voltage of ± 1.2 × 50ms according to JEC-212-1981
*
4
*
Excluding contact bounce time.
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
*
6
*
Half-wave pulse of sine wave: 6 ms
7
*
Detection time: 10 µ s
8
Refer to 5. Conditions for operation, transport and storage mentioned in
*
AMBIENT ENVIRONMENT (Page 24).
Max. 100 m Ω
3 A 277 V AC, 3 A
30V DC
831 V A (AC),
90W (DC)
2 × 10
5
LD-RELAYS
4. High shock resistance
The relay withstands a functional shock
resistance of 300m/s
more]
5. High insulation resistance
• Creepage distance and clearances between contact and coil: Min. 6 mm .236
inch(In compliance with IEC65)
• Surge withstand voltage between contact and coil: 10,000 V or more.
6. UL/CSA, VDE, TÜV approved.
Characteristics
Max. operating speed 20 cpm (at rated load)
Initial insulation resistance*
Between open
2
Initial*
breakdown
voltage
Initial surge voltage between contact
and coil*
Operate time*
contacts
Between contact and
coil
3
4
(at nominal voltage) Max. 10ms (at 20 ° C 68 ° F)
Release time (with diode)*
6
5
(at nominal voltage)
Temperature rise (at 70 ° C)
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and condensing at low temperature)
Unit weight Approx. 4 g .141 oz
1
4
Ambient
temp.
5
6
Min. 1,000 m/s
7
at double amplitude of 1.5mm
at double amplitude of 1.5mm
Functional*
Destructive*
Functional*
Destructive
8
Humidity 5 to 85% R.H.
2
[approx. 30 G
Min. 1,000 M Ω (at 500 V DC)
750 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Max. 10ms (at 20 ° C 68 ° F)
Max. 45 ° C with nominal coil
voltage and at 3 A contact
carrying current
(resistance method)
Min. 300 m/s
2
{approx. 30 G}
2
{approx. 100 G}
10 to 55Hz
10 to 55Hz
–40 ° C to +70 ° C
–40 ° F to +158 ° F
TYPICAL
APPLICATIONS
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
ORDERING INFORMATION
Ex. LDA12
Product name
LD
UL/CSA, TÜV approved type is standard.
Note: Standard packing: Carton: 50pcs, Case: 1,000pcs
Contact arrangement Coil voltage(V DC)
1: 1 Form A
1
4H: 4.5,
05: 5,
06: 6,
09: 9,
12: 12
18: 18
24: 24
47
Ω ( ±
±
±
LD
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Nominal
operating
currrent,
mA ( ± 10%)
Nominal
operating power ,
mW
Part No.
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
(Initial)
Drop-out voltage,
V DC (min.)
(Initial)
Coil resistance,
10%)
ALD14H 4.5 3.38 0.22 101 44.6 200 5.85
ALD105 5 3.75 0.25 125 40.0 200 6.5
ALD106 6 4.5 0.3 180 33.3 200 7.8
ALD109 9 6.75 0.45 405 22.2 200 11.7
ALD112 12 9 0.6 720 16.7 200 15.6
ALD118 18 13.5 0.9 1,620 11.1 200 23.4
ALD124 24 18 1.2 2,880 8.3 200 31.2
DIMENSIONS
Max. 20.5
.807
.016
0.4
Max. 15.3
.602
3.4
.134
Max. 7.2
.284
PC board pattern (Bottom view)
(1.05)
(.041)
(1.15)
(.045)
4.7
.185
11.5
.453
Maximum allow-
able voltage,
(at 20°C 68°F)
7.0
.276
V DC
mm inch
4-1.1 dia
4-.043 dia
0.2
0.4 dia
016 dia
1.05
.041
11.5
.453
.008
.008
7.0
.276
0.2
Dimension:
Max. 1mm .039 inch:
0.8
.031
4.7
.185
1.15
.045
General tolerance
0.1 ± .004
Schematic (Bottom view)
1 to 3mm .039 to .118 inch: ± 0.2 ± .008
Min. 3mm .118 inch:
0.3 ± .012
REFERENCE DATA
1. Max. switching power 2. Life curve 3. Coil temperature rise
3.0
2.0
1.0
0.5
Contact current, A
0.4
0.3
0.2
20 30 50 100 200 3000
AC resistive load
DC resistive load
Contact voltage, V
100
50
30
4
10
Life, ×10
0
123
125V AC
resistive load
Contact current, A
Sample: ALD112, 6 pcs.
Point measured: inside the coil
Contact current: 0 A, 3 A
70
60
Room temperature
50
40
30
Temperature rise, °C
20
10
0
1000 125 175150
Coil applied voltage, %V
Tolerance: ± 0.1 ± .004
0A
3A
70°C
4-(1). Operate time
Sample: ALD112, 6 pcs.
10
8
6
Operate time, ms
4
2
0
48
Min.
80 100 140120
Coil applied voltage, %V
Max.
4-(2). Release time (without diode)
Sample: ALD112, 6 pcs.
10
8
6
Release time, ms
4
2
0
80 100 140120
Coil applied voltage, %V
Max.
Min.
4-(3). Release time (with diode)
Sample: ALD112, 6 pcs.
10
8
6
Release time, ms
4
2
0
80 100 140120
Coil applied voltage, %V
Max.
Min.