LA
275
LA RELAYS
2 Form A slim power relay
mm inch
25.0
.984
24.0
.945
12.0
.472
FEATURES
1. 2 Form A slim type
24(L) × 12(W) × 25(H) mm
.945(L) × .472(W) × .984(H) inch
2. 3A type and 5A TV type
3A type: Contact reliability and break performance best suited for protecting and
switching speakers.
5A TV type: Tough against inrush current
and optimal for turning on and off the power supply. Rated TV-4 (UL/CSA).
3. High insulation resistance
• Creepage distance and clearances be-
tween contact and coil: Min. 6 mm .236
inch(In compliance with IEC65)
• Surge withstand voltage between contact and coil: 10,000 V or more.
4. High noise immunity realized by the
card separation structure between
contact and coil
5. Conforms to the v arious safety standards
• UL/CSA, VDE, TÜV, SEMKO, SEV approved
SPECIFICATIONS
Contact
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ± 1.2 × 50ms according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µ s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics
Type 3A rated 5A TV rated
Arrangement 2 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 50 m Ω Max. 100 m Ω
Contact material
Gold-clad
silver alloy
Silver alloy
Rating
(resistive
load)
Nominal switching
capacity
3 A 125 V AC 5 A 277 V AC
Max. switching power 625 VA 1,385 V A
Max. switching voltage 125 V AC 277 V AC
Max. switching current 5 A (AC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 10
6
Electrical (at 20 cpm)
(at rated load)
5 × 10
4
(ON: OFF=1.5s: 1.5s)
Nominal operating power 530 mW
Type 3A rated 5A TV rated
Max. operating speed 20 cpm
Initial insulation resistance*
1
Min. 1,000 M Ω (at 500 V DC)
Initial *
2
breakdown
voltage
Between contact sets 1,000 Vrms for 1 min.
Between open contacts 1,000 Vrms for 1 min.
Between contact and
coil
4,000 Vrms for 1 min.
Surge voltage between contact and
coil*
3
Min. 10,000 V
Operate time*
4
(at nominal voltage) Max. 15ms (at 20 ° C 68 ° F)
Release time (with diode)*
4
(at nominal voltage)
Max. 15ms (at 20 ° C 68 ° F)
Temperature rise (at 70 ° C)
Max. 45 ° C
with nominal
coil voltage
and at 3 A
contact carrying current
Max. 45 ° C
with nominal
coil voltage
and at 5 A
contact carrying current
Shock resistance
Functional*
5
Min. 200 m/s
2
{approx. 20 G}
Destructive*
6
Min. 1,000 m/s
2
{approx. 100 G}
Vibration resistance
Functional*
7
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 1.5mm
Conditions for operation,
transport and storage*
8
(Not freezing and condensing at low temperature)
Ambient
temp.
–40 ° C to +70 ° C
–40 ° F to +158 ° F
Humidity 5 to 85% R.H.
Air
pressure
86 to 106 kPa
Unit weight Approx. 13 g .46 oz
ORDERING INFORMATION
Contact arrangement
Contact capacity
Protective construction Coil voltage(V DC)
2: 2 Form A Nil: 3A
P: 5A TV-4
F: Flux-resistant type
12, 24
2
Product name
LA
Ex. LAAF12P
UL/CSA, VDE, TÜV, SEMKO, TV-4 approved type is standard.
Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 4.5V, 5V, 9V and 18V DC types are also available. Please consult us for details.