NAG SNR-CI-M User Manual

SNR-CI-M Series
Network IP Cameras User Manual
NETWORK HIGHSPEED DOME
MANUAL
Please read the operation manual carefully
before installing and using this unit
SNR-CI-M Series
Network IP Cameras User Manual
SAFETY PRECAUTIONS
CCCCAAAAUUUUTTTTIIIIOOOONNNN::::
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO DOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
CCCCAAAAUUUUTTTTIIIIOOOONNNN
RISK OF ELECTRIC
SHOCK. DO NOT OPEN!
The lighting flash with a arrowhead symbol, in an equilateral triangle, is intended to alert the user. There is uninsulated “dangerous voltage” presence near by the product's enclosure which may be risk of to persons .
The e x c l a m at ion point w i t hin an e q u i l a t e ral triangle is intended to alert the user to reference of t h e i m p orta n t o p erati n g a nd mai n t e nance (servicing ) instructions .
2
SNR-CI-M Series
Network IP Cameras User Manual
THE PRODUCT CODE MARKED ON THE BOTTOM COVER. PLEASE FILL THE CODE IN THE FOLLOWING BLANK. PLEASE SAVING THIS SPECIFICATION CAREFULLY, SO THAT CHECKING.
MODEL:________________________
PRODUCT CODE:________________________
3
SNR-CI-M Series
Network IP Cameras User Manual
INDEX
I. Important Safeguards.................................................... 5
II. Description of Functions................................................ 6
III. Setup of the Menu of the Dome Camera.................................. 7
IV. Setup of the Dome Camera.............................................. 11
V. The Installation of the System......................................... 11
VI. Technical data table.................................................. 14
VII. Troubleshooting (Software part in software manual) .................. 15
4
SNR-CI-M Series
Network IP Cameras User Manual
I. Important Safeguards
1. All the safety and operating instructions should be read before the units is operated.
2. This unit should be operated only from the type of power source indicated on the marking
label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For units intended to operate from battery power or other sources, refer to operating instructions.
3. During the course of transportation, storage and installation, the product should be avoided
from incorrect operations such as heavy pressing, strong vibration etc., which can cause damage of product as there are sophisticated optical and electronic devices inside the machine.
4.
Do not attempt to disassemble the camera. In order to prevent electric shock, do not remove screws or covers. There are no user-serviceable parts inside.
5. Always follow all electrical standards for safety when it is in operation. Adopt the particular power supply which is provided with the unit. RS-485 and video signal should keep enough distance with high voltage equipments and cables when they are in transmission. Precautions for anti-lightning and anti-surging should be taken if necessary.
6. Do not operate it in case temperature, humidity and power supply are beyond the limited stipulations.
7. Do not let the camera aim at the sun or the object with extreme light whatsoever it is switched on or not. Do not let the camera aim at or monitor bright and standstill object for a long time.
8. Do not use aggressive detergent to clean the main body of the camera. Wipe dirt with dry cloth. If needed, mild detergent can be used suitably.
9. Operate the intelligent speed dome camera with great care to avoid shock or vibration. It operate incorrectly, the Speed Dome could be damaged.
10.Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury to a person and serious damage to the unit. Use only with a stand, tripod, bracket, or mount recommended by the manufacturer or sold with the product. Any mounting of the unit should follow the manufacturer’s instructions and should use mounting accessory recommended by manufacturer.
11.If necessary, use a commercial lens cleaning paper to clear the lens windows. Gently wipe the lens window until clean.
5
SNR-CI-M Series
Network IP Cameras User Manual
II. Description of Functions
The network dome camera is a high-tech surveillance product, which integrated network transmission, high definition color camera, P/T, decoder, CPU and memory chip. Fast installation construction, more easy to install, enhanced the reliability of the system. Also it is easy to service.
The network dome camera achieves the long-distance control by network, and it is suitable for various situation.
1.
Integrated Speed-Variable PAN/TILT
a. Turning
adjustable speed from
120 rad/s.
360ºhorizontally and continuously with unlimited positions and an
0.2 - 300 rad/s
; turning
0 - 90º vertically with a speed up to
b. Running stably at low speed with super lower noise. Pictures have no
shaking.
c. Automatic
location precision up to
180º
flip and panoramic monitoring without blind point, the
±0.1°.
2. High Intelligent Degree
a. As much as 128 preset positions can be preset with powerless memory. b. The camera can scan horizontally between two points and scan speed can be
modified. The positions of linear scan are optional and the dome camera can scan the range larger or smaller than 180° between any two points with adjustable speed;
c. Six sets of programmable tour locus with 16 position each set. The running
speed and the detention time are adjustable respectively;
d. The dome camera can simulate the PTZ route operated by you in 40 seconds
by the self-learning function of the locus with powerless memory;
e. Character Overlapping. The humane structure of the menu makes all setups
and programming of the dome camera more convenient and easy.
f. Proportional pan function. The speed dome will depend on the amount of
zoom. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide zoom settings. This keeps the image from moving too fast on the monitor when there is a large amount of zoom. This slowing does not happen when going to a preset, but does occur in turbo mode when high zoom is selected. The minimum pan and tilt speeds are 0.1 degree per second at full zoom.
g. The Integrated Multi-Protocol. Multiple communication protocols are
integrated inside the dome camera with selectable baud rate from
9200 bps.
2400 bps to
3. Functions of the Camera (icons can be displayed on the screen when the option
6
SNR-CI-M Series
Network IP Cameras User Manual
DISPLAY of the camera is ON)
a. Description of the Focus Control Mode: the user can adjust the focus of the
camera manually. When the camera is on near focus, the icon appears on the screen; when on the nearest state, the icon appears while on the far focus, the icon appears.
b. Description of Backlight Compensation: when the object to be shot is dark
and looks dim, the user can open the backlight compensation according to actual need and the icon appears on the screen.
c. Description of White Balance: when the image has color distort on the
screen, the user can set different modes by orders. There are 6modes for options: Indoor Mode Outdoor Mode Touch Mode Automatic Trace of White Balance ATW Manual WB-MAN Automatic Mode.
d. Description of ZOOM Control: user can “pull near” or “push far” the lens
according to actual conditions, and the symbol appears on the screen in which the front part means optical multiplication while the rear part means digital multiplication.
e. Description of Electronic Shutter: it is fixed on 1/50 sec after initialization
when the camera is switched on, and the digital 50 appears on the screen.
f. Setup of Image Effect: the camera works on OFF state under normal
condition and no image effect symbol appears on the screen. When “B&W” appears on the screen, it means the camera is on black and white state.
g. AE Mode: setup of Manual/Automatic. h. Zero Illuminance: It is used only when the external brightness is extremely
low. Normally the camera works on the automatic state. In case the external brightness is lower than 1Lux, the camera can be switch to the Zero
Illuminance state automatically and icon appears on the screen. You can also set the Zero Illuminance state manually.
III. Setup of the Menu of the Dome Camera
1.
Basic Operation of the Menu
1.1 The main menu will be opened, when Call Preset 64 or Call Preset 1 twice in 4 minutes.
1.2 When the menu is displayed on the screen, operate “UP”, “DOWN” to move the
cursor to the option to be set, operate “LEFT”, “RIGHT” to modify the content or the order to enter this option.
1.3 Keep the joystick in one direction for over 1 second to speed up operation.
1.4 All setups on the menu couldn’t be lost even power failure happens.
1.5 Special utilizations can be seen on the descriptions of functions of the menu in detail.
2. Setup of the Menu
2.1 MAIN MENU
(Encl: Software manual
Encl: Software manual))))
Encl: Software manualEncl: Software manual
7
SNR-CI-M Series
Network IP Cameras User Manual
2.1.1 DISPLAY SETUP: to enter the submenu of display of the screen by which
ID display, title display of preset point and display of camera screen can be set.
2.1.2 CAMERA SETUP: to enter the submenu of setup
of normal data of camera.
2.1.3 CONTROL SETUP: to enter the submenu of
setup of control data over the dome camera.
2.1.4 CAMERA MASK SET: to enter the submenu of
setup of mask function of camera.
2.1.5 PROGRAM: to enter the setup of enhanced
function of dome camera.
2.1.6 PAL CAMERA: PAL/NTSC switching to suit the
camera.
2.1.7 CAM DEFAULT SET: to reset default setup of camera.
2.1.8 DOME RESET: to reset the dome camera.
2.1.9 EXIT: to quit the main menu.
2.2 DISPLAY SETUP
2.2.1 ID DISPLAY: when it is set at ON, address
of dome camera appears on the screen such as “CAM 001”. The default setting is ON.
2.2.2 ID POS: to set the display position of
address on one of following corners: TOP-L, TOP-R, BOTT-R and BOTT-L.
2.2.3 TITLE DIS: when it is set at ON, the title of
preset point appears on the left of screen such as "NO.001 ABCDEFGH” when the preset point is called. The modification of title of preset point is set on PROGRAM option.
2.2.4 TITLE POS: to set the display position of title of preset point from Line 1 to
Line 10. Line 1 is at the top of screen.
2.2.5 CAM DISPLAY: when it is set at ON, the camera screen will be opened.
2.2.6 RETURN: to return to MAIN MENU.
2.3 CAMERA SETUP
2.3.1 SLOW SHUTTER: frame accumulation with
two options Manual/Automatic. When camera screen is opened under automatic state, ASS displays on screen.
2.3.2 BACK LIGHT: backlight compensation
ON/OFF.
2.3.3 ICR SHOT: low shootingON/AUTO
2.3.4 IRIS: setup of automatic iris AUTO/MANU.
2.3.5 D-ZOOM: setup of digital zooming ON/OFF.
2.3.6 FOCUS: setup of automatic focusing AUTO/ MANU.
2.3.7 WB SET: setup of white balance. ATW / INDOOR / OUTDOOR / ONEPUSH
/ AUTO / MANU
2.3.8 MENU OF CAM: blank
2.3.9 RETURN: return to MAIN MENU.
2.4 CONTROL SETUP
8
SNR-CI-M Series
Network IP Cameras User Manual
2.4.1 AUTO FLIP: 180° automatic flip of dome camera ON/OFF.
2.4.2 ALARM: blank.
2.4.3 PRESET PIC: if image is followed when calling preset point or making tour.
FREEZE – when switching scene to freeze image and to recover otherwise; MOVE – when switching scene no image frozen.
2.4.4 HOME OPTION: enter the submenu of
automatic home function.
2.4.4.1 AUTO HOME: when it is set at ON, home
function is available, namely, the dome camera will return HOME if user has no action in a period of time. The dome camera shall not return HOME if it is on tour state. If no HOME is needed when the dome camera is stopped, set the option at OFF.
2.4.4.2 HOME POS: HOME means return home. For example to set one scene as
HOME, call the scene first and set it as preset point, then call out the menu to enter into this submenu, change figures after HOME POS into 5. If automatic HOME function is needed, do not forget to set AUTO HOME at ON. The preset points of HOME POS are from 1 to 63 and 65 to 128.
2.4.4.3 DWELL TIME: to set the time of automatic HOME, which means the
camera shall return HOME if it is not controlled in a period of time which can be from 1 to 99 minutes.
2.4.4.4 RETURN: return to the menu one level higher.
2.4.5 RETURN: return to MAIN MENU.
2.5 CAMERA MASK SET
2.5.1 MASK PRIVACY: blank.
2.5.2 MASK SHADE: blank.
2.5.3 MASK REGION: blank.
2.5.4 RETURN: return to Main Menu.
2.6 PROGRAM Options
2.6.1 AUTO PAN START POS: To set start position of auto scan between two
points. To move the dome camera by joystick after entering and to return by CLOSE button.
2.6.2 AUTO PAN END POS: To set end position of auto scan between two points.
To move the holder by joystick after entering and to return by CLOSE button.
2.6.3 RUN AUTO PAN: Auto scan function between two points. First of all, you
must set the start position and the end position of auto scan. If the start position is just the end position, it means 360° scan. The speed of auto scan has six grades: FAST / NORMAL / SLOW / -FAST / -NORMAL / -SLOW in which the first three grades are scan less than 180° while the later three grades larger than 180°. Adjust speed by PAN LEFT/PAN RIGHT, and operate and exit by OPEN button. The start position and the end position of auto scan are set by options 1 and 2 in this submenu.
2.6.4 SET TITLE: to edit titles of preset position.
Only previous 63 preset points have their titles. Select no. of preset point by PAN LEFT/PAN
9
SNR-CI-M Series
Network IP Cameras User Manual
RIGHT, enter into edit by OPEN button and exit edit by CLOSE button. Operations under edit state can be seen later.
2.6.5 SET PATROL: to edit data for multi-points patrol. Select no. of patrol by PAN
LEFT/PAN RIGHT, enter into edit by OPEN button and exit edit by CLOSE button. Operations under edit state can be seen later.
2.6.6 RUN PATROL: to run multi-points patrol function. Select no. of patrol by
PAN LEFT/PAN RIGHT, run and exit by OPEN button.
2.6.7 RECORD PATTERN: This pattern can consist of any standard pan and tilt or
lens command. Presets, flip, digital zoom, proportional pan, and turbo are not allowed in a pattern. The pattern length is 40 seconds in maximum. To return
when 40 seconds expire or by push CLOSE button.
2.6.8 RUN PATTERN: to self-learn loci of tour. To exit the menu after running or
to stop running by joystick.
2.6.9 RETURN: return to Main Menu.
3. Appendix to the Menu
3.1 Operation of Edit State of Multi-Points Patrol. When entering into edit state
the screen displays as follows:
NO – serial No. of patrol position POS – No. of preset position SP – leaving speed TM – dwelling time
After entering into edit area, screen shows as follows:
Edit Area, data of 2 patrol position appears on one line.
SEQ:01 – It means the set No.1 patrol
CLOSE:EXIT – Push CLOSE to exit edit state
Both top and bottom lines display prompt and information of each patrol is displayed on the middle of the screen. Data of 2 Patrol points appears on one line. Move cursor by PAN LEFT/RIGHT and modify data by TILT UP/DOWN. Press buttons for one second to speed up operation. Press CLOSE button to exit edit state and store modifications. The program will search the position of the first “---” of POS, store dada before it and regard data after it as invalid. In above figure, the program stores previous four points with settable range from 1 to 63 and from 65 to 128. When “---” of POS appears, the tour range is ended. The settable range of SP is from 0 to 8 (0 and 1 are the same with fastest speed while 8 has the lowest speed). The settable range of TM is from 0 to 99 seconds.
3.2 Operation of Title of Preset Point in Edit State. When entering into edit state
the screen displays as follows: In the figure we find the preset point is No.1 with title of “NO TITLE”. Move cursor by PAN LEFT/RIGHT and modify data by TILT UP/DOWN. Press buttons for one second to
10
SNR-CI-M Series
Network IP Cameras User Manual
speed up operation. Press CLOSE button to exit edit state and store modifications. The title of preset point has 8 characters in maximum such as 0-9, A-Z, +, - and space. Note: the first character should be 0-9 or A-Z, otherwise it means to delete the title of the preset point, and when preset point is adjusted, only “NO.XXX” spears without title to be displayed.
IV. Setup of the Dome Camera
1. System connection
1)
The system map of the dome
V. The Installation of the System
1Installation manner
a)
Hanging
11
SNR-CI-M Series
Network IP Cameras User Manual
1.
Open the packing, take out the dome and the accessories.
2. Fix the dome with the bracket well (as Figure 4-1 & 4-2).
3.
Fix the bracket on the wall (as Figure 4-3).
Figure 4-1
8
Figure 4-2
12
SNR-CI-M Series
Network IP Cameras User Manual
b) Ceiling
Figure 4-3
Figure 5
Figure 6 Dome down lead
Φ7
Notice:
13
SNR-CI-M Series
Network IP Cameras User Manual
The lines of the POWER SUPPLY and the LAN is the default, other down-leads
will be made by client’s order.
4. To Ensure a Smooth and Successful Installation, You Should:
1Have electrical work to comply with latest national electrical code, national
fire code, and all applicable local codes and ordinances. 2Coordinate with other trades to avoid interference. 3Verify existing conditions on the site and coordinate with owner side to ensure
necessary utilities available. 4Copy all related plans, specifications, shop drawings and attachments to
schedule and coordinate related work.
5
Thoroughly review the project to ensure that all jobs should meet or exceed
the above requirements. Contact with the CCTV Project Coordinator to draw
attention in case alleged discrepancies occur.
VI. Technical data table
Image Inductor
Pixels In-Phase System In-Phase Inside Video Output White Balance Auto / Manual
Specificatio ns
Camera
Function
Lens
Parameter
Dome
Function
Power Supply
Power Consumption
Weight
Opposite Humidity Environment Temperature 0℃~40℃
Scan System 15.625 KHz (H) 50Hz (V) Horizontal 480 Horizontal Signal-to-Noise > 48 db Shutter Sensitivity Zoom Rate Iris Auto / Manual Focus Auto / Manual Pan Speed Tilt Speed
1/4C 752 H×582 V440000 pixelsPAL
1.0 Vp-p/75Ω
AC 24V±10% 1.25A (with fan/heater) 30 VA (with fan/heater) 15 VA (indoor) 2 Kg 4 Kg (with 10-75 %
1/31/10000 sec
0.011 lux (F1.6) 18×Optical and 12×Digital
0300°/s 0120°/s
olor CCD
aluminum alloy ball
)
14
SNR-CI-M Series
Network IP Cameras User Manual
Preset 128 presets (max) Auto Cruise At best 6 cruises Pattern 40 sec.
VII. Troubleshooting (Software part in software manual)
Problems Possible Causes Remedies
Power supply fault Replace
No action when power is switched on
Bad connection of the power
Transformer damaged Replace
Correct
Abnormal self-check. Images with motor noise
Normal self-check but no images
Normal self-check but out of control
Vague image
Dome camera out of control
Mechanical failure Repair
Camera inclined Reinstall
Power supply not enough Replace Video signal fault Reinstall Bad connection of the video Press to connect well
Camera damaged Replace
RS485 bus bad connection
Dome ID setup is wrong Reselect
Protocol setup is wrong
Bad connection of the video Press to connect well Power supply not enough Replace Self check error Switch ON again Bad connection of control Press to connect well
Check the RS485 connection
Reset and Switch ON again
Bad control of matrix Switch ON again
15
SNR-CI-M Series
Network IP Cameras User Manual
Appendix I: The Cleaning of Clear Down Cover
To obtain constant clear videos, user should clean the down cover periodically. Be cautious when cleaning. Hold the down cover ring only to avoid direct touch to the
acrylic down cover. The acid sweat mark of fingerprint will corrode the coating of down cover and scratch on down cover will cause vague images.
Use soft dry cloth or the substitute to clean the inner and outer surfaces.  For hard contamination, use neutral detergent. Any cleanser for high-grade furniture
is applicable.
Appendix II:Wire Diameter and Transmission Distance Comparison Chart
Wire diameter (mm)
Transmission
Distance
Power [VA]
10
20
30
40
50
60
70
80
90
0.8000 1.000 1.250 2.000
feet(m)
28386 451137 716218 1811551
14142 22568 358109 905275
9428 15045 23872 603183
7021 11234 17954 452137
5617 9027 14343 362110
4714 7522 11936 30191
4012 6419 10231 25878
3510 5617 8927 22668
319 5015 7924 20161
100
110
120
130
288 4513 7121 18155
257 4112 6519 16449
237 3711 5917 15045
216 3410 5516 13942
16
SNR-CI-M Series
Network IP Cameras User Manual
140
150
160
170
180
190
200
206 329 5115 12939
185 309 4714 12036
175 288 4413 11334
164 267 4212 10632
154 257 3911 10030
144 237 3711 9528
144 226 3510 9027
APPENDIX III: Wire Gauge Conversion Chart
Bare wire diameter metric
size
mm
AWG
(Approximate)
(Approximate)
SWG
Bare wire cross sectional
area
mm2)
0.050 43 47 0.00196
0.060 42 46 0.00283
0.070 41 45 0.00385
0.080 40 44 0.00503
0.090 39 43 0.00636
0.100 38 42 0.00785
0.110 37 41 0.00950
0.130 36 39 0.01327
0.140 35 0.01539
0.160 34 37 0.02011
0.180 33 0.02545
0.200 32 35 0.03142
0.230 31 0.04115
17
SNR-CI-M Series
Network IP Cameras User Manual
0.250 30 33 0.04909
0.290 29 31 0.06605
0.330 28 30 0.08553
0.350 27 29 0.09621
0.400 26 28 0.1237
0.450 25 0.1602
0.560 24 24 0.2463
0.600 23 23 0.2827
0.710 22 22 0.3958
0.750 21 0.4417
0.800 20 21 0.5027
0.900 19 20 0.6362
1.000 18 19 0.7854
1.250 16 18 1.2266
1.500 15 1.7665
2.000 12 14 3.1420
2.500 4.9080
3.000 7.0683
18
Loading...