Nady Systems PCL-800, PCL-815 Owner's Manual

Page 1
RACK LIGHTS
POWER CONDITIONER & LIGHT MODULE
1800 WATTS CA PACITY
PULL
PULL
MI
N MAX
VOLTAGE
STANDARD
VOLTAGE
DIMMER
REAR OUTLETS
ON
OFF
CHO3080
CHO3081
Page 2
Congratulations!
PCL
Serie
s
Power
Conditioner
s
For advanced RF/EMI noise
filtering
and the quietest
operation of your equipment...
Triple mode varistor surge and spike protection
Eight rear outlets (with room
for
4 ¡°w
all
wa
rts¡±)
controlled by a front panel switch
15 amp rating (1800 W) with rear panel circuit
breaker (UL)
Two added front panel slide-out, swiveling lights for
rack illumination and dimmer controls to adjust lamp brightness (PLC-810 and PLC-815 only)
Large LED numeric meter that displays incoming
AC line voltage and 2 voltage condition indicators-
standard voltage and over voltage (PLC-815 only)
Rugged single rack space metal housing for maxi-
mum reliability
Date of Purchase
Dealer¡¯s Name
City
State
Zip
Model #
Serial #
You have purchased one of the finest professional power conditioners on the market toda y. This unit was devel­oped using the expertise of professional sound engineers and working musicians. You will find your new unit has superior perform
ance
and greater flexibility than any other power conditioner in its price range. Read this manual carefully to get the most out of your new unit..
2
PCL-800 Power conditioner
PCL-815 Power conditioner with lights and
AC meter display
Features
Features ...........................................
W
a
r
ning..........................................
Controls,
functions
,
connections
..........
Installation and operatio
n...................
Specifications......................................
CONTENTS
2
3
4
6
7
Page 3
3
Page 4
Controls, functions, and connections
FRONT
PANEL
1.
POWER
SWITCH Outlet switch (with built-in LED ON indicator) activates protection and filtration to all back panel outlets. To tu r n the unit ON or OFF, press the upper or lower portion of this button.
2. 2 RETRACTABLE RACK LIGHTS Pull out for illumination and swivel to desired angle
3.
LIGHT SWITCH Activates rack illumination
4. DIMMER CONTROL Use to control the intensity of the illumination. Turning clockwise increases the light output.
5. DIGI TAL
VOLTMETER
READOUT
Displays incoming AC line voltage
6.
VO LTAGE LED METER
Separate green and red LEDs monitor the incoming voltage range. The green LED indicates voltage is in the normal operating range. The red LED lights when the voltage exceeds 125 V, indicating that the supplied power is out of range for normal operation.
4
RACK LIGHTS
POWER CONDITIONER & LIGHT MODULE
1800 WATTS CA PACITY
PULL
MI
N MAX
OVER
VOLTAGE
STANDARD
VOLTAGE
DIMMER
REAR OUTLETS
ON
OFF
2
4
3
1
5
6
2
6
Page 5
REAR
PANEL
7. POWER CORD
Heavy duty 14-gauge power cord for connection to the AC power mains (120V-60Hz)
8. CIRCUIT BREAKER
Resettable 15 amp ther mal circuit breaker
9. 8 REAR PANEL OUTLETS
EMI/RFI filtered, spike/surge protected and switched
5
7
8
9
Page 6
6
1. The PCL Series conditioners are the perfect accessories for any rack mount system. Install in the top slot of a standard 19-inch rack, and the 8 switched AC outlets on the rear panel will provide full safety protection to all your rack equipment. These conditioners protect your delicate electronic equipment by combining a high voltage varistor surge and transient suppressor with an RFI/EMI interference filter. The filter helps prevent noise from fluorescent lights, motors, and similar sources of “electronic pollution” from contaminating the AC feed to your senitive video, audio, vtr or computer circuits.
2. Plug Power Cord (7)into a standard grounded 120V outlet
3. Plug sensitive electronic equipment into the
8 Rear Panel Outlets (9)
4. Turn Outlet Power Switch (1)to “ON” position. Lit LED indicates conditioned power to the connected equipment.
5. For discreet illumination of your rack equipment on stage, in studios, and in other dark locations
815
only), pull the 2 Retractable Rack Lights (2) out and adjust the Dimmer Control (4) for the lamp brightness desired (see fig.1 below). The lights swivel and can be adjusted to the proper angle for your appli­cation. The lamps are supplied with standard 5W night-light bulbs. If you find the heat from the bulbs exces­sive, reduce the setting of the Dimmer Controlor substitute lesser wattage bulbs. You can easily replace the bulbs without removing the unit from the rack by unscrewing the cap on the end of each light tube.
(Note: Be
careful not to push the tubes in while the caps are unscrewed.)
6. The Digital Voltmeter Readout (5)(PCL-815 only) is calibrated to a nominal 117 VAC at the factory. No adjustments are necessary.
7. The Digital Voltmeter Readout
(5)
automatically displays incoming voltage when the Power Cord (7)
is connected.
8. MAXIMUM LOAD: The PCL Series Power Conditioners 8 Rear Panel Outlets are rated at 15 amps total load (or 1800W at 120VAC). If this maximum load is exceeded, the Circuit Breaker (8) will trip, cutting of f power to all connected equipment in your rack. If this happens, reduce the load by unplugging one or more units from the power conditioner, and push the circuit breaker to reset it (see fig.2 below).
Installation and operation
fig.2
fig.1
Page 7
Specifications
PROTECTION PROVIDED High voltage varistor surge and transient suppressor,
RFI/EMI interference filtration OUTLET CONNECTORS 8 standard 3-prong grounded AC receptacles POWER CONSUMPTION Maximum 1800W/15A load POWER SOURCE ~120VAC/60 Hz CIRCUIT BREAKER 15A thermal type LAMPS (PCL-815) 5W (two) DIMENSIONS 19” X 1.75” X 7.3”
(483 X 44 X 185mm), 1U rack height
WEIGHT PCL-800 4.45 lbs (2.0 Kg)
PCL-815 4.55
lbs (2.07 Kg)
For improvement purposes, specifications, design and appearance subject to change without prior notice
7