UUSSEE AANNDD MMAAIINNTTEENNAANNCCEE MMAANNUUAALL FFOORR TTHHEE FFOOAAMMTTEECC 11880000
NOTE: As with all electrical equipment, care and att ention must be exercised at all times
during its use, in addition to ensure that routine and preventative maintenance is carried out
periodically in order to ensure safe operation. In particular the electrical supply cable should
be regularl y inspected by a competent pers on and immediate action tak e n to rectify any
faults found. Failure to carry out maintenance as necessary, including replacement of parts
to the correct standard, could render the equipment unsafe and the manufacturer can accept
no responsibility in this respect.
____________________________________________________
Before using your machine
, you must familiarize yourself with all of its components.
NaceCare Solutions
1205 Britannia road east
Mississauga, Ontario, Canada
L4W 1C7
Toll Free: 1 800 387 3210
Toll Free Fax: 1 800 709 2896
Overview
The FoamTec 1800 is a restroom care machine that sprays foaming chemical onto surfaces
that need cleaning. Next, the foam and the dirt are removed by rinsing the surfaces with
clean water. Then, with the same machine, you can also vacuum the liquid from hard floors.
The FoamTec has been designed for cleaning and sanitizing fixtures and other surfaces in
restrooms and shower areas in the education sector and in areas open to public, such as
train stations, airports, rest areas, swimming pools, fitness centres, saunas, hospitals, hotels
and so on. The FoamTec can be used in any other place where the foam + rinse + vacuum
system is convenient.
Safety instructions (read carefully)
Every electrical device must be used only for its particular function, respecting the
manufacturer’s instructions. Failure to follow the instructions could result in serious bodily
injury to the operator (electric shock, electrocution, etc.). Today, machines are produced
according to accident prevention regulations and qualified safety institutes approve them.
However, irresponsible use may put people in serious danger. Carefully read the following
points and be sure to understand everything before using the mac hine.
• Before connecting the machine’s plug to the electrical socket, check that the voltage available
is the same as indicated on the label of the machines.
• Be sure that the electrical system is grounded and that it is supplied with a ground fault
interrupter. (GFI)
• Verify that the electrical plug complies with the wall outlet.
• Do not use adapters or multiple sockets without knowing the electrical input of each device
connected to the socket.
• If any electrical extension is used, check that it corresponds to the absorbed power of the
machine. It must be sealed against water.
• Take care of the cable. It is essential that it is protected from water, tearing and chemical
agents. Do not repair the cable if it is damaged replace it with a new one.
• Do not pull the cable to move the machine or to extract the plug from the socket. Pull out the
socket only when the machine is switched off.
• Do not handle the electrical plug with wet hands.
• Do not spray water near outlets. Do not use the machine to spray or to suck corrosive liquids
(acids or bases), explosive or flammable liquids (gasoline, kerosene, solvents, etc.) or dust.
• Do not use the machine in an explosive environment.
• Do not allow the machine to be used by children and persons unable to understand the danger
connected with using electrical power.
2
Safety instructions (CONT’D)
• Do not bring the end of the suction hose or one of the accessories near yours or others’ face,
particularly near ears and eyes: the sucked air could seriously damage them.
• If the machine is used as a wet vacuum cleaner, you must check the water level in the recovery
tank regularly to avoid water being sucked in by the vacuum motor.
• Avoid vacuuming a large quantity of foam. The foam may be sucked into the vacuum motor and
damage it. Follow steps from paragraph “Working method”.
• In case of abnormal function (very noisy motor, pump not on, extreme temperature rise, etc.)
switch the machine OFF and pull out the plug.
After use, clean the machine and store it in a dry and closed place.
Construction of the machine
The FoamTec 1800 is comprised of the following parts:
• The lower t ank contai ns the clean water
• The upper tank is the recovery tank
• The discharge for the recovery tank is at the rear of the machine
• The pumps and vacuum motor are situated inside the lower tank
• The air compressor is located in the box underneath the bottom tank.
• The control panel located on the upper tank houses all of the switches for the pump,
vacuum motor, and air compressor.
• Attached to the lower tank is a tray for the one gallon foaming chemical and the anti-
foam chemical.
• The vacuum hose plugs in to the rear of the recovery tank. Attached to the cuff of the
vacuum hose is the defoamer line. The defoamer is dispensed automatically while
using the vacuum.
• The blower outlet is located on the right side of the solution tank.
• The air compressor is located inside the box situated inside the metal casing at the
bottom of the machine
Accessories included
• 33 foot wire reinforced vacuum hose 1 ½ inch
• 6 foot stretch blower hose 1 ¼ inch, that expands up to 30 feet, c/w blower nozzle
• Single piece double “S” bend floor wand c/w hard floor squeegee tool and handle hook
• 50 foot spray / rinse hose
• High / low pressure spray gun
• Window / mirror squeegee
• Hard floor brush and handle
3