NaceCare Solutions HZD750 User Manual

NUMATIC - HZD 750WD
Wet/Dry Hazardous Dust Vacuum
NOTE: As with all electrical equipment, care and attention must be exercised at all
times during its use, in addition to ensuring that routine and preventative maintenance is carried out periodically in order to ensure its safe operation. In particular the electrical supply cable and flexible hose should be regularly inspected by a competent person and immediate action taken to rectify any faults found. Failure to carry out maintenance as necessary, including replacement of parts to the correct standard, could render the equipment unsafe and the manufacturer can accept no responsibility in this respect.
_____________________________________________________
MACHINE COMPONENTS
Powerhead
The 2 bypass vacuum motors are housed within the Structofoam powerhead. To start the vacuum motors simply activate this switch. The head cannot be removed from the HEPA filter module under normal circumstances as the 2 steel toggles on the side of the module are secured with cotter pins.
HEPA Filter Module
The HEPA filter itself is located within the yellow steel chamber mounted to the powerhead. The purpose of the steel module is to protect the HEPA filter from tampering The HEPA filter is capable of filtration to 99.97% even if the intake of the machine is completely blocked.
The code for the replacement filter is NVM 25B. Replacement of the HEPA filter must be carried out by qualified personnel.
Standard Wet/D
ry
Filt
er Assembly
The HZD 750 W/D is equipped with a combination wet & dry main filter assembly. This consists of a black wet shut-off assembly with a ball float on top of which is a secondary white Permatex 0.5 micron nylon filter on which is placed a steel filter grid The purpose of the filter grid is to keep the white Permatex material clear of the air inlet underneath the HEPA module. Do NOT use the machine without the filter grid in place as this may cause overheating.
If the machine is to be used in a wet application, it is essential that the secondary dry Permatex filter be used as a dry barrier between the wet filter assembly & the HEPA module. If this is not done, the working life of the HEPA filter will be drastically reduced and its filtering capability will be compromised.
The wet filter assembly float ball rises up when fluid levels reach the maximum capacity of the vacuum tank. When this occurs, the pitch of the vacuum motors increases indicating that the vacuum should be turned off and the container emptied.
Spare Dry Filter - NVM 16B
The HZD 750 W/D is provided with a primary white Permatex dry filter assembly. This is part of the standard BB20 kit. This dry filter can be used when the machine is to be used for a dry only application. In that case, the above mentioned wet/dry filter assembly should be removed completely and the primary dry filter put in its place.
Optional Microtex Filter - NVM 10C
As an optional accessory for DRY USE ONLY the HZD 750 W/D may be fitted with a Microtex filter. When this filter is used it must always be used with the primary Permatex filter as a pre-filter. It is nesessary to remove the black filter grid from the Permatex filter and place it inside the yellow Microtex filter.
The Microtex filter is capable of filtration efficiency of over 99% at .3 microns. This filter will prolong the life of the HEPA filter.
Vacuum Tank
The recovery tank of the HZD 750 W/D is made of galvanized steel and coated with a yellow epoxy powdercoat paint finish to help prevent corrosion To empty debris, simply remove the powerhead and filters and then release the steel toggle at the rear of the machine. This allows the tank drum to be removed from the cart. The drum is equipped with carrying handles on the side to facilitate lifting.
After wet use it is recommended to allow the drum to dry out before storage.
For handling and disposal of hazardous debris, always be sure to comply with local regulations.
2