Märklin 60883 User manual [ml]

Rückmeldemodul L88
60883
Inhaltsverzeichnis:
Seite Bestimmungsgemäße Verwendung 4 Sicherheitshinweise 4 Wichtige Hinweise 4 Ein- und Ausgänge des Link 88 4 Anschluss 5 Anschluss Übersicht 6 Konfiguration des L88 8 Nutzung als Tasten-Matrix 12
Sommaire :
Page Utilisation conforme à sa destination 24 Remarques importantes sur la sécurité 24 Information importante 24 Entrées et sorties du Link 88 24 Connectez 25 Vue d’ensemble des branchements 26 Configuration du L88 28 Utilisation comme matrice de touches 32
Table of Contents:
Page Using the Product as Intended 14 Safety Notes 14 Important Notes 14 Inputs and Outputs for the Link 88 14 Connect 15 Overview of Connections 16 Configuration for the L88 18 Use as a Button Matrix 22
2
Pagina Beoogd gebruik 34 Veiligheidsvoorschriften 34 Belangrijke aanwijzing 34 In- en uitgangen van de Link 88 34 Aansluiten 35 Aansluit overzicht 36 Configuratie van de L88 38 Benutten als drukknoppen-matrix 42
Indice de contenido:
Página Uso correcto 44 Instrucciones de seguridad 44 Notas importantes 44 Entradas y salidas del Link 88 44 Montaje 45 Esquema sinóptico de conexionado 46 Configuración del L88 48 Uso como matriz de teclas 52
Innehållsförteckning:
Sidan Användning av produkten 64 Säkerhetsanvisningar 64 Viktig information 64 In- och utgångar på Link 88 64 Anslutning 65 Översikt: Anslutninga 66 Konfiguration av L88 68 Användning som knapp-matris 72
Indice del contenuto:
Pagina Impiego commisurato alla destinazione 54 Avvertenze per la sicurezza 54 Avvertenze importanti 54 Entrate e uscite del Link 88 54 Collegamento 55 Panoramica delle connessioni 56 Configurazione dello L88 58 Utilizzo come matrice di tasti 62
Indholdsfortegnelse:
Side Hensigtsmæssig anvendelse 74 Sikkerhedshenvisninger 74 Vigtige bemærkninger 74 Ind- og udgange på Link 88 74 Tilslutning 75 Tilslutningsoversigt 76 Konfiguration af L88 78 Anvendelse som tastematrix (kontrolpanel) 82
3
Bestimmungsgemäße Verwendung
• Das Rückmeldemodul L88 ist für den Anschluss an die
Central Stationen (CS2) 60213/60214/60215 ab der Soft­ware Version 3.8.xx und höher bestimmt. Anschluss der Rückmeldemodule 6088 (S88)/60880 (S88)/60881
• (S88 AC) und 60882 (S88 DC) an oben genannte Central Station.
• Das Rückmeldemodul L88 Link ist ein Rückmelder mit 16
Meldekontakten für das Märklin H0-Mittelleitergleis.oder 2L Gleise (Spur 1, Trix H0, Minitrix) mit Reed Kontakten
• Bzw. Anschluss bis zu 64 Taster.
Sicherheitshinweise
• Die Spannungsversorgung des L88 Link erfolgt aus­schließlich über das Schaltnetzteil 66361 oder 66201.
• Anschlussarbeiten am Rückmeldemodul L88 Link dürfen
nur im spannungslosen Zustand erfolgen.
ACHTUNG! Funktionsbedingte scharfe Kanten und Spitzen.
• Das Gehäuse darf nicht geöffnet werden.
• Das Rückmeldemodul L88 Link ist ausschließlich zum
Gebrauch in trockenen Räumen bestimmt.
Wichtige Hinweise
• Die Bedienungsanleitung ist Bestandteil des Produktes
und muss deshalb aufbewahrt sowie bei Weitergabe des Produktes mitgegeben werden.
• Für Reparaturen wenden Sie sich bitte an Ihren Märklin-
Fachhändler.
• Gewährleistung und Garantie gemäß der beiliegenden
Garantieurkunde.
• Entsorgung: www.maerklin.com/en/imprint.html
4
Ein- und Ausgänge des Link 88
Stromversorgung: Schaltnetzteil 66361 oder 66201. Anschluss an Central Station / Terminal
Masserückführung (bei Verwendung als Rückmelder)
1-16 Kontaktanschluss (Märklin H0 Mittelleitergleis
oder Taster) Bus 1 60881 oder 60882 Bus 2 60881 oder 60882 Bus 3 6088 und/oder 60880 Schalter für Stromversorgung der S88 Module mit 5V oder 12V.
Schalter Stromver­sorgung S88/S88AC/
S88DC
Stromversorgung
60881/60882
60880/6088
5V
Bus 1 Bus 2Bus 3
12V
66361 oder 66201
Central Station / Terminal
Masserück-
führung
S88 Link
T
1
456
2 3
Gleis oder Taster
7
8
91011
60881/60882
T
15
16
121314
Masserück-
führung
Anschluss
Anschluss an die Central Station
Den Link 88 direkt an den Boosteranschluß der CS2 oder an das Terminal 60125
anschließen, danach die Stromversorgung 66361 oder 66201 einstecken.
5V
Bus 1 Bus 2Bus 3
12V
Central Station / Terminal
S88 Link
T
1
2 3
456
T
121314
15
16
7
8
91011
5
Anschluss Übersicht
An einen Link 88 können maximal 31 S88 und/oder 62
S88AC/S88DC angeschlossen werden.
87654321
decoder s 88
910111213141516
Max. 31x S88
Ein bestehender Anschluss des S88 an der Central Station 2 kann beibehalten werden
Bus Bus
Max. 31x
S88 AC oder DC
Bus Bus
S88 AC
T
1
7
6
4
2 3
5
T
15
8
91011
16
121314
Bus 3
S88 DC
T
1
2 3
S88 AC oderDC
Bus 2
7
456
8
Max. 31x
T
16
15
9
11
12
14
10
13
Bus 1
Stromversorgung 66361+60822
S88 Link
T
1
2 3
Bus 1 Bus 2Bus 3
7
456
12V
5V
8
91011
121314
Schalter Stromversorgung S88/S88AC/S88DC = 5V/12V (Siehe nächste Seite)
T
15
16
CS2 oder Terminal
6
Stromversorgung:
5V im Mischbetrieb von Märklin S88 und S88 AC/DC (wie in Abb. dargestellt), sowie Produkten anderer Anbieter.
12V nur in Verbindung S88 AC/DC. Bei einer Stromversorgung mit 12V wird die Störanfälligkeit verringert.
PIN Belegung Pin RJ45
Pin S88 Name Beschreibung Pin RJ45
Farbe
EIA/TIA 568A
1 D ATA Auslesedaten 2 grün 2 GND Masse für Signale und Versorgungsspannung 3 weiss/orange 2 GND 5 weiss/blau 3 CLOCK Taktsignal für die Synchronisation 4 blau 4 PS (LOAD) Lade die Informationen in den Bus 6 orange 5 RESET Zurücksetzen der Eingangsspeicher 7 weiss/braun 6 +5V/+12V Versorgungsspannung für die Rückmeldemodule 1 weiss/grün
SHIELD Kabelabschirmung, nicht angeschlossen
Märklin übernimmt keine Haftung bei gemeinsamer Nutzung von Märklin Produkten und Produkten anderer Anbieter. Wir empfehlen daher dringend die PIN Belegungen des RJ45 Steckers zu prüfen.
7
Konfi guration des L88
Vor Inbetriebnahme des L88 muss dieser erst konfi guriert werden. Dazu gehen Sie in der CS auf setup/Info, nun mit
dem Symbol Werkzeug nachfolgende Abbildungen sind Beispiele:
klappen sie die Info aus
Wählen sie Link S88 #17,
8
in den Konfi gurationsmodus. Alle
jetzt können die einzelnen Daten eingestellt werden.
Auswertung Bus 0 (direkter Bus des L88),
Einstellung Einzeln = 16 Melde Kontakte
Einstellung Matrix = bis zu 64 Taster
• Länge Bus 1-3
Hier wird eingetragen wieviel S88 an jedem Bus ange-
schlossen sind (max. 31).
• Zykluszeit Bus 1-3
Abfragezyklen der S88 Busse in ms (min 10ms - max. 1000 ms)
eintragen (werkseitig 100ms).
• Bitzeit S88
Einstellen Zyklus der Antwort (werkseitig 167µs)
• Zykluszeit (Link 88) Kontakt 1 - 16
Abfragezyklus der Link Kontakte bei Verwendung als Gleis-
kontakt 1 - 16.
• Zykluszeit Tastastatur
Abfragezyklus bei Verwendung als Tastatur (werkseitig 67ms).
• Spalten (Ausgang) Tastatur
Eintragen der Spalten (max. 8) der Tastatur Matrix
• Zeilen (Eingang) Tastatur
Eintragen der Zeilen (max. 8) der Tastatur Matrix
Adressierung der Module:
Die Module adressieren sich durch das Einstecken automa­tisch. Für die Einstellungen in der Central Station finden Sie nachfolgend die Adresssen.
Kontakte (Gleis): 1-16 Tasteradressen: 101-164
Bus 1: 1001 -1496 (z.B. 1005 = 1. Modul, Kontakt 5)
Bus 2: 2001 - 2496 Bus 3: 3001 - 3496
Beispiele von Einstellungen an der Central Station:
Einstellungen an der Central Station:
1. Nutzung als Gleiskontakt:
1.1 Verwendung im Memory (Beispiel): gehen Sie in Konfigurationsmodus
Über Button Erw. in die erweiterte Einstel­lung springen.
Angemeldetes Gerät auswählen
z.B. Kontakt 8
Modul 2 Bus 2
1.2 Verwendung im Layuot (Beispiel): gehen Sie in Konfigurationsmodus und definieren den Kontakt
Adresse (Kontakt) eingeben
Gerät auswählen
Funktion wählen, wenn erforderlich
Gerätetausch.
Wird ein Gerätetausch notwendig, kann der neue L88 auf die
bisherige Gerätenummer umgestellt werden. Die Umstellung
erfolgt nach Anmeldung des Link 88 in der CS unter setup ­Werkzeug - Geräte - bearbeiten. Geben Sie dort dem neuen Link 88 ihre bisherige Gerätenummer ein und bestätigen
Sie dieses. Danach ist ein Neustart der CS notwendig, nun
funktionieren alle Kontakte wie gewohnt.
9
Beispiele für den Anschluss der verschiedenen Melde-Kontakte
Masserückführung für alle Gleis-Kontakte nur 1x erforderlich.
Anschluss an das Märklin H0-Gleissystem mit dem Schaltgeis
= Meldende Fahrt-
richtung
Fahrtrichtungsabhängige Meldung.
Anschluss an das Märklin H0-Gleissystem mit Kon­taktgleisen
Fahrtrichtungsunabhän­gige Meldung
10
Bus 1 Bus 2Bus 3
S 88 Link
T
1
2 3
S 88 Link
T
1
2 3
5V
7
6
4
8
5
5V
Bus 1 Bus 2Bus 3
7
6
4
8
5
91011
91011
12V
T
15
16
12
14
13
12V
T
15
16
12
14
13
Anschluss an das Märklin H0-Gleissystem mit Reedkontakt.
Fahrtrichtungsunabhängige Meldung
Masserückführung ist pro Reed-Kontakt erforderlich
Bus 1 Bus 2Bus 3
S 88 Link
T
1
2 3
12V
5V
7
6
4
8
91011
5
T
15
16
12
14
13
Anschluss an Zweileiter-Gleis­systeme, unabhängig von der Spurgröße nur mit Reedkontakt.
Fahrtrichtungsunabhängige Meldung
Bus 1 Bus 2Bus 3
S 88 Link
T
1
2 3
12V
5V
7
6
4
8
91011
5
T
15
16
12
14
13
11
72720 / 72729 / 7272
Nutzung als Tasten-Matrix (Stellpult):
Wollen Sie den L88 für eine Tasten-Matrix verwenden, dann müssen folgende Einstellung vorgenommen werden.
Durch die Einstellung Matrix können max. 64 Taster (32 Ma­gnetartikel oder 64 Fahrstraßen) unterstützt werden. Für den
Aufbau wird pro Taster zusätzlich eine Diode 1N4148 benötigt,
Einbaurichtung beachten.
Kontakt 9-16 (Eingang/Zeilen)
9
12
10
11
Kontakt 1-8 (Ausgang/
1
Spalten)
2
3
4
12
Anschluss Stellpult Es können max. 8 Stellpulte (Eingang 9 - 16) angeschlossen
werden.
10
Eingang
9
1 2 3 4 5 6 7 8
Nun muss jeder Taste eine Fahrstraße zugeordnet werden.
Achten Sie darauf, dass die Fahrstraßen im Memory auf Automatik-Betrieb eingestellt sind. Die Einstellungen erfolgen
im Konfigurationmodus des Memory (siehe Anleitung der Central Station).
Die Zuordnung erfolgt über die Taste
Einstellungen für Fahrtstrasse.
in den erweiterten
Geben sie zuerst die Adresse der Taste ein (Tabelle S.13).
Ausgang
Danach das zugeordnete Gerät (hier 17) eintragen.
Ist alles richtig eingetragen, bestätigen Sie es mit dem
grünen Haken. Auf dem jetzt im Display erscheinenden Bild mit dem blauen Pfeil zwischen speichern. Danach weitere
Fahrstraßen bearbeiten oder mit dem grünen Haken bestätigen und beenden.
Adressierung der Tasten (Beispiele)
Taste 25 =125
Taste 26 = 126
Taster
(Eingang)
12
11
18 - 24
25 - 32
10
9 - 17
Taste 9 = 109
9
1 - 8
Taste 1 = 101
1 (Ausgang)
Taste 2 = 102
2 (Ausgang)
Adresstabelle für die Tasten
Bitte beachten, die Diode muss in Sperrrichtung zum Ausgang
eingebaut sein. Beispiel Taster 1: Ausgang 9 angeschlossen an Eingang 1 erhält
die Adresse 101.
(Eingang)
Eingang
Ausgang
9
1 (Ausgang)
9 10 11 12 13 14 15 16
1 101 109 117 125 133 141 149 157 2 102 110 118 126 134 142 150 158 3 103 111 119 127 135 143 151 159 4 104 112 120 128 136 144 152 160 5 105 113 121 129 137 145 153 161 6 106 114 122 130 138 146 154 162 7 107 115 123 131 139 147 155 163 8 108 116 124 132 140 148 156 164
13
Using the Product as Intended
• The L88 feedback module is designed for connection
to the L88 (60883) and the 60213/60214/60215 Central Stations (CS2) with Software Version 3.8.xx and higher. Connections from the 6088/60880/60881 and 60882 feedback
modules to the Central Station units mentioned above.
The L88 Link feedback module is a position indicator with 16 indicator contacts for Märklin H0 center conductor track or for 2-rail track (1 Gauge, Trix H0, Minitrix) with reed contacts.
• Or connections to 64 button controllers.
Safety Notes
• The voltage supply for the L88 Link is done only by means
of the 66361/66365 or 66201 switched mode power pack.
• Connections to the L88 Link feedback module may only be
done with no voltage present.
WARNING! Sharp edges and points required for operation.
• The housing must not be opened.
• The L88 Link feedback module is designed only for use in
dry areas.
Important Notes
• The operating instructions are a component part of the
product and must therefore be kept in a safe place as well as included with the product, if the latter is given to someone else.
• Please see your authorized Märklin dealer for repairs
• The warranty card included with this product species
the warranty conditions.
• Disposing: www.maerklin.com/en/imprint.html
14
Inputs and Outputs for the Link 88
Current supply: 66361/66365 or 66201 switched mode power pack. Connections to the Central Station / Terminal
Ground return (when used as a position indicator)
1-16 Contact connections (Märklin H0 center conductor
track or button controllers)
Bus 1 60881 or 60882 Bus 2 60881 or 60882 Bus 3 6088 and/or 60880 Switches for current supply to the S88 Module with 5 volts or 12 volts.
60881/60882
Switches for current supply
60881/60882
60880/6088
S88/S88AC/ S88DC
Current supply
Bus 1 Bus 2Bus 3
12V
5V
66361/66365 or 66201
Central Station / Terminal
Ground Return
S88 Link
T
1
456
2 3
Track or Button
7
8
91011
121314
Controller
T
15
16
Ground Return
Connect
Connections to the Central Station
Connect the Link 88 directly to the Booster connection on the CS2 or to the 60125 Terminal. After that plug in the 66361/66365 or 66201 power supply.
5V
Bus 1 Bus 2Bus 3
12V
Central Station / Terminal
S88 Link
T
1
2 3
456
T
121314
15
16
7
8
91011
15
Overview of Connections
A maximum of 31 S88 units and/or 62 S88AC/S88DC
units can be connected to a Link 88.
87654321
decoder s 88
910111213141516
Maximum
31 x S88
An existing connection from the S88 to the Central Station 2 can be kept.
Bus Bus
16
S88 AC
T
Maximum 31 x
S88 AC or DC
Current supply 66361+ 60822 US only: 66365
CS2 or Terminal
Bus Bus
1
7
6
4
8
2 3
91011
5
S88 DC
T
1
7
456
2 3
T
15
16
121314
T
16
15
8
9
11
12
14
10
13
Maximum 31 x
S88 AC or DC
Bus 3
Bus 2
Bus 1
12V
5V
Bus 1 Bus 2Bus 3
Switches for current supply S88/S88AC/ S88DC = 5V/12V
S88 Link
T
1
7
456
2 3
15
8
91011
16
121314
(see next page)
T
Current Supply:
5volts in mixed operation of S88 and S88 AC/DC Märklin products (as shown in the illustration), as well as products of other
makes.
12 volts only in conjunction with the S88 AC/DC. The susceptibility to interruptions is reduced with a 12 volt power supply.
PIN Assignment for the RJ45 Plug
S88 Pin Name Description PIN RJ45
Color
EIA/TIA 568A
1 D ATA Readout Data 2 green 2 GND Ground for signals and voltage supply 3 white/ orange 2 GND 5 white/blue 3 CLOCK Clock signal for the synchronization 4 blue 4 PS (LOAD) Load the data into the bus 6 orange 5 RESET Reset the input memory 7 white/brown 6 +5V/+12V Voltage supply for the feedback module 1 white/green
SHIELD Cable shield, not connected
Märklin assumes no liability for joint use of Märklin products and products of other makes. We therefore urgently recommend that you check the PIN assignments of the RJ45 plug you may be using.
17
Confi guration for the L88
The L88 must fi rst be confi gured before using it for the fi rst
To do this go into the CS to setup/Info and with the tool
time. symbol images are examples:
Open up Info
Select Link S88 #17.
18
go into the confi guration mode. All of the following
Now the individual data can be set..
Evaluation of Bus 0 (direct bus for the L88), Setting for individual units = 16 indicator contacts Setting for matrix = up to 64 button controllers
• Length of Bus 1-3
Here you enter how many S88 units are connected to each bus (max. 31).
• Cycle period for Bus 1-3
Enter query cycles for the S88 busses in milliseconds (ms) (min 10 ms - max. 1000 msm, factory setting 100 ms).
• Bit time for the S88
Set the cycle for the answer (factory setting 167 µs)
• Cycle period for (Link 88) Contacts 1 - 16
Query cycles for the Link contacts when used as track contacts 1 - 16.
• Cycle period for keyboard
Query cycle when used as a keyboard (factory setting 67 ms).
• Columns for the keyboard
Entering the columns (max. 8) for the keyboard matrix
• Rows for the keyboard
Entering the rows (max. 8) for the keyboard matrix
Addresses for the Module:
The module automatically get an address when it is plugged in. You will find below the addresses for settings in the Central Station.
Contacts (track): 1-16 Button controller addresses: 101-164
Bus 1: 1001 -1496 (ex. 1005 = 1st module, Contact 5)
Bus 2: 2001 - 2496 Bus 3: 3001 - 3496
Examples of Settings on the Central Station:
Settings on the Central Station:
1. Use as a track contact:
1.1 Use in the Memory (example) Go into the Configuration mode
Jump over Button to the advanced setting.
Select a registered device
e.g. Contact 8
Modul 2 Bus 2
1.2 Use in the Layout (example) Go into the Configuration mode and define the contact
Enter address (contact)
Select device
Select function, if necessary
Swapping Devices.
If a device swap becomes necessary, the new L88 can be switched to the previous device number. The switch takes place after the Link S88 registers in the CS at setup –Tool
–Devices - edit. Enter the new Link S88 there with the
previous device number and confirm this number. After that, the CS needs to be rebooted. All of the contacts will function as usual.
19
Sample Connections for the Different Feedback Contacts
Only one ground return is required for all track contacts.
Connections to the Märklin H0 track system with the Circuit Track
= Direction of tra-
vel feeding back
Feedback is dependent on the direction of travel
Connections to the Märklin H0 track system with Contact Tracks
Feedback is independent of the direction of travel
20
Bus 1 Bus 2Bus 3
S 88 Link
T
1
2 3
S 88 Link
T
1
2 3
5V
7
6
4
8
5
5V
Bus 1 Bus 2Bus 3
7
6
4
8
5
91011
91011
12V
T
15
16
12
14
13
12V
T
15
16
12
14
13
Connections to the Märklin H0 track system with Reed Switches
Feedback is independent of the direction of travel
Ground return is required per reed switch
Connections to two-rail track sys­tems, independent of the gauge
only with Reed Switches.
Feedback is independent of the direction of travel
Bus 1 Bus 2Bus 3
S 88 Link
T
1
2 3
S 88 Link
T
1
2 3
5V
7
6
4
8
5
5V
Bus 1 Bus 2Bus 3
7
6
4
8
5
91011
91011
12V
T
15
16
12
14
13
12V
T
15
16
12
14
13
21
72720 / 72729 / 7272
Use as a Button Matrix (Control Box):
If you want to use the L88 for a button matrix, then the following setting must be done.
A maximum of 64 button controllers (32 solenoid devices or 64 routes) can be supported by the setting Matrix. A 1N4148 diode per button is required for the setup. Pay attention to the installation direction.
Contact 9-16 (input) line
9
12
10
11
1
Contact 1-8 (output) Column
2
3
4
22
Connections for a Control Box
A maximum of 8 control boxes (Inputs 9 - 16) can be con­nected.
10
Input
9
1 2 3 4 5 6 7 8
Now every button must be assigned to a route. Make sure, that the routes in the Memory are set for automatic operation.
The settings are done in the configuration mode for the Memory (see instructions for the Central Station). The assignment is done by means of the button advanced settings for a route.
in the
You first enter the address for the button (see table page 23).
Output
After that enter the assigned device (here 17).
Address Table for the Buttons
Please note, the diode must be installed in the blocking direction at the output.
Example Button 1: 9 output connected to input 1 is replaced by the address. 101.
(Input)
9
If everything has been entered correctly, confirm it with the green check mark. Store in memory along the way with the blue arrow on the display now appearing in the image. After that edit or process other routes or confirm with the green check mark and end the process.
Addresses the button (Example)
Button 25 =125
Button 26 = 126
Taster
(Input)
12
11
18 - 24
25 - 32
10
9 - 17
Button 9 = 109
9
1 - 8
Button1 = 101
1 (Output)
Button 2 = 102
2 (Output)
1 (Output)
Input
Output
9 10 11 12 13 14 15 16
1 101 109 117 125 133 141 149 157 2 102 110 118 126 134 142 150 158 3 103 111 119 127 135 143 151 159 4 104 112 120 128 136 144 152 160 5 105 113 121 129 137 145 153 161 6 106 114 122 130 138 146 154 162 7 107 115 123 131 139 147 155 163 8 108 116 124 132 140 148 156 164
23
Utilisation conforme à sa destination
• Le module de rétrosignalisation L88 DC est conçu pour être
branché aux Central Stations (CS2) 60213/60214/60215 à partir de la version logicielle 3.8.xx et plus.
Branchement des modules de rétrosignalisation 6088/60880/ 60881 et 60882 à la Central Station mentionnée ci-dessus.
• Le module de rétrosignalisation L88 Link est un module
disposant de 16 contacts de signalisation pour la voie à conducteur central H0 de Märklin ou les voies 2L (piste 1, Trix H0, Minitrix) avec des contacts Reed
• Ou branchement de max. 64 contacts.
Remarques importantes sur la sécurité
• L‘alimentation en tension du L88 Link se fait exclusivement par le biais d‘une alimentation de coupure 66361 ou 66201.
• N‘effectuez les travaux de branchement sur le module de
rétrosignalisation que lorsque le L88 Link est hors tension.
ATTENTION! Pointes et bords coupants lors du fonction- nement du produit..
• Le boîtier ne doit pas être ouvert.
• Le module de rétrosignalisation L88 Link ne doit être
utilisé que dans des pièces sèches.
Information importante
• La notice d‘utilisation fait partie intégrante du produit ; elle doit donc être conservée et, le cas échéant, transmi-
se avec le produit.
• Pour toute réparation adressez-vous à votre détaillant-
spécialisé Märklin.
• Garantie légale et garantie contractuelle conformément
au certificat de garantie ci-joint.
• Elimination : www.maerklin.com/en/imprint.html
24
Entrées et sorties du Link 88
Alimentation électrique : Alimentation de coupure 66361 ou
66201. Branchement à la Central Station / au Terminal
Retour par la terre (pour une utilisation en tant que rétro-
signalisation)
1-16 branchements de contact (voie à conducteur
central H0 de Märklin ou touche) Bus 1 60881 ou 60882 Bus 2 60881 ou 60882 Bus 3 6088 et/ou 60880 Interrupteur pour alimentation électrique des modules
S88 à 5 V ou 12 V.
Interrupteur pour alimentation élec­trique S88/S88AC/
60881/60882
60880/6088
S88DC
Alimentation
Bus 1 Bus 2Bus 3
électrique 66361 ou 66201.
Central Station / Terminal
Retour par la
terre
S88 Link
T
1
456
2 3
Voie ou touche
7
5V
8
12V
91011
60881/60882
T
15
16
121314
Retour par
la terre
Connectez
Branchement à la Central Station
Branchez le Link 88 directement sur la prise booster du CS2 ou au terminal 60125, puis branchez la prise électrique 66361 ou 66201.
5V
Bus 1 Bus 2Bus 3
12V
Central Station / Terminal
S88 Link
T
1
2 3
456
T
121314
15
16
7
8
91011
25
Vue d’ensemble des branchements
Vous pouvez brancher au maximum 31 S88 et/ou 62
S88AC/S88DC au Link 88.
87654321
decoder s 88
910111213141516
Max. 31x S88
Une connexion existante du S 88 à la Central
Station 2 peut être conservée.
Bus Bus
Max. 31x
S88 AC ou DC
CS2 ou Terminal
26
Bus Bus
S88 AC
T
1
7
6
4
2 3
5
T
15
8
91011
16
121314
Bus 1
Alimentation électrique 66361+60822
S88 Link
T
1
2 3
Bus 3
Bus 1 Bus 2Bus 3
456
S88 DC
T
1
7
456
2 3
T
16
15
8
9
11
12
14
10
13
Max. 31x
Bus 2
12V
5V
Interrupteur pour alimentation élec-
S88 AC ou DC
trique S88/S88AC/S88DC = 5V/12V
(voir la page suivante)
7
T
15
8
91011
16
121314
Loading...
+ 58 hidden pages