This scale has a stability indicator, the letter “S” in the top left corner of the
screen. Whenever the letter “S” is displayed that means the displayed weight
is stable.
***IF YOU HAVE QUESTIONS OR NEED ASSISTANCE PLEASE VISIT
WWW.MYWEIGH.COM
VERY QUICKLY SO PLEASE CONTACT US IF YOU NEED ANY HELP. IF
YOU WANT TO LEARN MORE ABOUT YOUR SCALE OR NEED
REPLACEMENT PARTS, VISIT WWW.MYWEIGH.COM
There is an advanced troubleshooting and programming guide av ailable onli ne
for this scale at our website.
Words of Advice:
The Cigarette Case scale is undoubtedly one of the coolest pocket scales ever
created and the first of it’s kind. Please remember that this is a precision
instrument. It is essential that you never drop, shake or otherwise mishandle
this instrument. Electronic precision scales use delicate sensors that can
easily be damaged if the scale is excessively shocked, dropped or overload.
An abused scale will only work until it’s sensors are damaged, but a well kept
scale will last for your lifetime.
WE CAN USUALLY HELP YOU FIX YOUR SCALE
Please be good to your Cigarette Case scale!
My Weigh is the Best Weigh !
Page 2
CIGARETTE CASE SCALE
OPERA TION AND CALIBRA TION INSTRUCTIONS
This scale is very easy to operate. However, there are certain caring and
operation instructions you should read before your first use
the time to read these instructions is time consuming, but this scale is a
precision instrument and must be handled with the upmost care.
IMPORTANT:
1) To open the scale, simply press the unlock button and lift up the cover.
2) Always empty the platform before turning the power on (clear the platform
before turning on).
3) Do not get the scale wet or hot and do not operate on any wet or hot
surface. To clean the scale, wipe the surface with a clean damp cloth or
mild non-abrasive cleaner. Do not use any abrasive cleaner because it may
damage the finish.
4) Do not overload the scale. That is, do not place anything that weighs
more than 300 grams on the platform. You may permanently damage the load cell.
5) Handle the scale with care. This is a precision instrument and should never
be dropped or otherwise mishandled.
6) Do not leave anything on the scale when not is use.
7) If the scale is excessively cold or hot, allow the scale to warm up to normal
room temperature for at least 1 hour prior to use.
We know taking
8) Do not operate a cell phone or cordless phone within 10 feet of the scale**** It may temporarily cause the scale to malfunction.
9) If the scale ever reads “Lo” or weighs very slowly, please replace the
batteries.
10) In the unlikely event that the scale permanently “locks up” or shows ERR,
visit www.myweigh.com
11) If your scale should require recalibration, please refer to the calibration
guide on the next page.
12) Please keep your scale in it’s protectiv e pouch when not in use.
for Advanced Troubleshooting.
Page 3
INSTRUCTION MANUAL
1. Do not put anything on the scale tray before you turn it on.
2. Turn the scale on by pressing ON. After 2 seconds, the display will read
“0.0g”.
3. Always allow the scale to warm up for at least 30 seconds before weighing
for accuracy & stability.
4. Place the item to be weighed on the center of the platform and read the
value on the display.
5. TARE Function: If you need to weigh loose items or anything in a
container or tray you should: 1) Turn the scale ON. 2) Place the empty
container or tray on the platform. 3) Press the TARE button. 4) Place the
items to be weighed into the container / tray. 5) The exact weight of the
items will show.
6. The scale has an Auto-Off feature that turns off t he scale after lapses of
non-activity. If the scale is in a room with wind or air movement, it may
sense the pressure of the air and not auto-off. In this case simply press
OFF to turn the scale off manually.
7. MODE Function: This scale has the ability to weigh in grams or ounces.
The selection is done by simply pressing the MODE key once the scale is
on (Look for the g, oz, ozt, dwt or ct on the top of the display).
8. BACKLIGHT: Place the item on the platform and the backlight will be
automatically turned on. Aft er the item is removed (display shows 0.0g), the
backlight will be turned off automatically after a few seconds.
9. Temperature: The recommended operating temperature is 64-82F
(16-25C). Please only operate the scale at recommended temperatures.
CAPACITY OF SCALE: 300G ACCURACY: +/- 0.1g
Page 4
CALIBRATION INSTRUCTIONS
THIS SCALE IS ACCURATE WITHIN 0.1g, only calibrate if your readings are
inaccurate beyond 0.1g. Allow your scale to warm up for several seconds
before calibration. Always m ove your hands very gently during calibration as t o
not cause vibrations or air movement.
1. PLACE THE SCALE ON A FLAT SURFACE THAT HAS NO VIBRATIONS
AND MAKE SURE THERE IS ABSOLUTELY NO AIR MOVEMENT.
(SURFACE MUST BE EXTREMELY STABLE).
2. TURN THE SCALE OFF AND CLEAR THE PLATFORM (MAKE SURE
NOTHING IS ON THE PLATFORM).
3. TURN THE SCALE ON BY PRESSING THE ON KEY. WHEN THE
DISPLAY SHOWS 0.0, WAIT 5 SECONDS.
4. PRESS AND HOLD THE ON KEY FOR 3 SECONDS UNTIL IT SHOWS “0”,
THEN RELEASE THE KEY.
5. IT WILL THEN SHOW “300.0”. THE UNIT “g” WILL KEEP FLASHING.
ADJUST THE FIGURE USING THE TARE KEY IF NECESSARY, (e.g.
CHANGE TO 100.0 for 100g CALIBRATION). PLACE THE
CORRESPONDING WEIGHT (e.g. 100g) ON THE CENTER OF THE
PLATFORM AND WAIT FOR 5 SECONDS.
6. THE SCALE WILL SHOW “100.0” AND THE UNIT “g” WILL STOP
FLASHING AFTER THE CALIBRATION IS COMPLETE.
IF THE READINGS ARE INACCURATE, PERFORM CALIBRATION AGAIN.
IF YOUR SCALE WILL NOT PROPERLY CALIBRATE OR SHOWS “ERR”
PLEASE VISIT OUR WEBSITE FOR ADVANCED CALIBRATION &
TROUBLESHOOTING INSTRUCTIONS
BATTERY INSTRUCTIONS
USE TWO AAA BATTERIES. PLEASE MAKE SURE THE POLARITY IS
CORRECT WHEN INSTALLING NEW BATTERIES. LOW BATTERIES ARE
THE #1 CAUSE OF SCALE MALFUCTION SO BE SURE YOUR BA TTERIES