Myuet ME55 User Manual

ME55 Programmable Heating Thermostat with LCD Screen User manual
Shenzhen Myuet Energy Saving Equipment Co., Ltd. 1
Programmable Heating Thermostat with LCD Screen
Weekly circulation, it is possible to set 6 periods called events
each day with corresponding pre-set temperatures. You can
requirement. The thermostat is recommended for control of
electric heating devices or on/off valve actuator used in water-
based system.
Availability
Mode
Current
Application
ME5503
3A
For control of electric actuator or
electrothermal actuator
ME5516
16A
For control of electric actuator or
electrothermal actuator
ME5523
3A
For control of electric actuator or
electrothermal actuator, a potential a
potential-free output
ME5533
3A
A pair of contacts for potential-free output
Technical data
Voltage: 110-230V AC ,50/60Hz Power consumption: 2W
Temperature setting range: 5-95
Temperature limitation range: 5-60(factory setting: 35)
Switching differential: 0.5-10 adjustable, factory setting ±1
Ambient temperature: -5~50 Protective housing: IP20
Housing material: anti-flammable PC Dimensions(H/W/D): 90/86/43mm
User Operation
1) Power key
Press the key to turn on/off the thermostat, you can also confirm and exit through it when completing the setting of every parameter.
2) The increase key and decrease key”
Press “” or””key to adjust temperature and the value of
pre-set temperature will be increased/decreased by 0.5 each
time in “manual mode” or “ period control mode”. Furthermore,
in “period control mode” apart from value change its alternate
display also stops, it will recover the alternate display with no
operation for 3 seconds.
3) Time setting
Press key and hold for 5 seconds
simultaneously to adjust time. Press to choose object for adjusting ; press ” or” to increase
/decrease your set values. Press to confirm and exit.
4) Mode selection key
You can select “period control mode” or “manual mode” by
this key. In “ period control mode”, it displays the time or
the pre-set temperature alternately, and the measured
temperature displayed directly. Press and hold for
5 seconds to enter the mode of period programming.
5) Locking and unlocking
Press and simultaneously and hold for 5 seconds,
the thermostat will be locked / unlocked. When locked, no
operation can be carried out until it is unlocked.
Display symbols
Manual mode
Period control mode
Wake-up, event 1
Leave, event 2
Return(am), event 3
Leave(pm), event 4
Return(pm), event 5
Sleep, event 6
Heating on
Programming: 6 –event time and temperature
Press key and hold for 5 seconds to enter programming
mode.
Key
Event
Symbol
Time
Default
value
Week day
1 06:00
Set time
20
Set temperature
2 08:00
15
3 11:30
15
4 12:30
15
5 17:00
22 6 22:00
15
Weekend
1 08:00
22
2 23:00
15
Advanced setting (qualified person preferred)
Press and at the same time to enter the mode of advanced setting immediately when thermostat is turned off. The
following ten functions can be chosen by key.
Symbol
Setting
or
1
ADJ
Temperature calibration
Adjust measured temperature
2
SEN
Sensor mode
IN: built-in sensor OUT: floor sensor ALL: both sensor
3
LIT
Limitation temperature
Adjust limitation value, limitation
range:5-60.
4
DIF
Switching differential
Adjust switching differential
5
LTP
Anti-frozen function
Turn on/off Anti­frozen function
6
PRG
Kinds of periods of time mode
5+2 day mode 6+1 day mode 7 day mode
7
RLE
Potential –free output and main power output in the same/different way
Change the present linkage way 8 DLY
Delay time of potential-free output
Change linkage delay time
9
HIT
Max .temperature
Max. limitation temperature
setpoint: 95
AFAC
Reset to factory setting
Press and hold for 5s then
all parameters will be reset.
ME55 Programmable Heating Thermostat with LCD Screen User manual
Shenzhen Myuet Energy Saving Equipment Co., Ltd. 2
Sensor failure
Please select the right sensor mode when operation, it will display Er symbol for sensor failure, thermostat must be checked till the fault is eliminated.
Product diagram
Dimensions(mm)
Mounting steps
1. Release the front cover by inserting a screwdriver into
bottom crack.
2. Take the back plate apart according to following diagram.
3. Install the thermostat in electrical connection box with
screws.
4. Install the housing cover and lock the external frame.
Connecting Diagram
Attention: The thermostat which connect the electric heating devices is
apply to full load(3200W) heating cable in 2500m height above sea level, and the rated power of external load should be less than or equal to 80% rated power thermostat when in 2500 to 4200m height.
Loading...