Mytek Studio Clock 192CX – User Manual
This manual may be updated
Download the newest version at:
For technical support, technical tips and support check:
http://www.mytekdigital.com
or contact Mytek tech support at:
highend@mytekdigital.com
or at:
tel. (347) 384-2687
fax. (212) 202-5331
Mytek Digital
148 India St. FL 1
Brooklyn, NY 11222
USA
www.mytekdigital.com Page: 2 / 9
Mytek Studio Clock 192CX – User Manual
Content
Introduction..................................................................................4
Quick Start....................................................................................5
Front Panel....................................................................................5
Back Panel.....................................................................................6
Functions....................................................................................... 6
Table of Frequencies....................................................................7
Important Safety Instructions.....................................................8
www.mytekdigital.com Page: 3/9
Mytek Studio Clock 192CX – User Manual

Introduction

The Mytek Studio Clock 192CX is a house clock generator/distributor that is designed specifically for audio applications. It can generate its own clock based on the ultra stable, ultra low jitter internal clock generator, or it can redistribute an external wordclock source.
www.mytekdigital.com Page: 4/9
Mytek Studio Clock 192CX – User Manual

Quick Start

1. Connect Clock Signal Lines
Connect the FS WCK out to the wordclock input of your device. Set the receiving device to slave to the external wordclock signal.
2. Operation
Once the unit is powered on it will generate wordclock based on the settings on the front panel.
3. Configuration
The FS selector cycles through the standard audio sampling rates. You can choose 44.1 kHz, 48 kHz, 88.2kHz, 96 kHz, 176.4 kHz, and 192 kHz. The unit can also be used to redistribute an external clock source.

Front Panel

STUDIO CLOCK 192CX
96
192
48
ULTRA
PRECISION
INTERNAL
OSCILLATOR
CX7 97
A – Sampling Frequency Selector
B – Sampling Frequency Indicator
C – Clock Source Selector
D – Clock Source Indicator
E – Wordclock In Multiplier Selector
FS
A
176.4
88.2
44.1
MYTEK DIGITAL.USA
AAB
D
FS=
E
C
SOUR CE
WCK IN
INT OSC
F
WCK INx4
WCK INx2
WCK IN
I
O
G
F – Wordclock In Multiplier Indicator
G – Power Switch
www.mytekdigital.com Page: 5/9

Back Panel

Mytek Studio Clock 192CX – User Manual
110/220VAC
A
SWITCH AND FUSE INSIDE
B
SUPERCK OU T
C
WCK IN
A – IEC Power socket
B – Wordclock Input
C – Superclock Output
D – FS Wordclock Outputs
E – FS/2 Wordclock Output
F – FS/2/4 Wordclock Output
DESIGNED IN USA
D
6x FS WCK OUTS
MADE IN PO LAND
E
FS/FS:2 OUT
FS/FS:2/FS:4 OUT
F
AES OUT
FS
G
WWW .MYTEKDIGITAL .CO M
G – AES/EBU XLR Clock Output

Functions

FS – This cycles the sampling frequency between 44.1, 48, 88.2, 96, 176.4, and 192 kHz.
SOURCE – This selects whether the Internal Oscillator or the External Wordclock In is the clock source.
FS= – This multiplies the incoming wordclock by x1, x2, or x4.
WCK IN – This is for connecting an external clock source.
FS WCK OUT – This outputs wordclock at the selected
sampling frequency.
SUPERCK OUT – This is always outputting Superclock.
FS/FS:2 OUT – This clock output divides the selected
sampling frequency by 2.
FS/FS:2/FS:4 OUT – This clock output divides the selected sampling frequency by 2 and 4.
www.mytekdigital.com Page: 6/9
Mytek Studio Clock 192CX – User Manual

Table of Frequencies

Internal Oscillator (INT OSC)
FS FS WCK OUT FS/FS:2 OUT FS/FS:2/FS:4 OUT
44.1 kHz 44.1 kHz 44.1 kHz 44.1 kHz
48 kHz 48 kHz 48 kHz 48 kHz
88.2 kHz 88.2 kHz 44.1 kHz 44.1 kHz
96 kHz 96 kHz 48 kHz 48 kHz
176.4 kHz 176.4 kHz 88.2 kHz 44.1 kHz
192 kHz 192 kHz 96 kHz 48 kHz
External Wordclock (WCK IN)
Ext. Clock FS FS= FS WCK
OUT
44.1 kHz 44.1 kHz x1 44.1 kHz 44.1 kHz 44.1 kHz
48 kHz 48 kHz x1 48 kHz 48 kHz 48 kHz
88.2 kHz 88.2 kHz x1 88.2 kHz 44.1 kHz 44.1 kHz
96 kHz 96 kHz x1 96 kHz 48 kHz 48 kHz
176.4 kHz 176.4 kHz x1 176.4 kHz 88.2 kHz 44.1 kHz
192 kHz 192 kHz x1 192 kHz 96 kHz 48 kHz
44.1 kHz 44.1 kHz x2 44.1 kHz 44.1 kHz 44.1 kHz
44.1 kHz 88.2 kHz x2 88.2 kHz 44.1 kHz 44.1 kHz
48 kHz 48 kHz x2 48 kHz 48 kHz 48 kHz
48 kHz 96 kHz x2 96 kHz 48 kHz 48 kHz
88.2 kHz 176.4 kHz x2 176.4 kHz 88.2 kHz 44.1 kHz
96 kHz 192 kHz x2 192 kHz 96 kHz 48 kHz
FS/FS:2
OUT
FS/FS:2/FS:4
OUT
44.1 kHz 44.1 kHz x4 44.1 kHz 44.1 kHz 44.1 kHz
44.1 kHz 88.2 kHz x4 88.2 kHz 44.1 kHz 44.1 kHz
44.1 kHz 176,4 x4 176.4 kHz 88.2 kHz 44.1 kHz
48 kHz 48 kHz x4 48 kHz 48 kHz 48 kHz
48 kHz 96 kHz x4 96 kHz 48 kHz 48 kHz
48 kHz 192 kHz x4 192 kHz 96 kHz 48 kHz
www.mytekdigital.com Page: 7/9
Mytek Studio Clock 192CX – User Manual

Important Safety Instructions

• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
• When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power­supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
www.mytekdigital.com Page: 8/9
Mytek Studio Clock 192CX – User Manual
WARNING
Excessive sound pressure from speakers and headphones can cause hearing loss. In order to use this product safely, avoid prolonged listening at excessive sound pressure levels.
For the customers in the U.S.A. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This product with the CE marking complies with the EMC Directive issued by the Commission of the European Community. Compliance with this directive implies conformity to the following European standards:
• EN55103-1 : Electromagnetic Interference (Emission)
• EN55103-2 : Electromagnetic Susceptibility (Immunity) This product is intended for use in the following Electromagnetic Environments: E1 (residential), E2 (commercial and light industrial), E3 (urban outdoors), E4 (controlled EMC environment, ex. TV studio).
www.mytekdigital.com Page: 9/9