Contents
1.
1. Introduction ...........................................................................................4
2. Package Content .....................................................................................5
3. Features .................................................................................................5
4. Quick Start..............................................................................................6
5. OPERATING MODES and their settings ....................................................7
6. USB ........................................................................................................8
7. Firmware update Windows and OS X ......................................................8
8. Technical Specication ............................................................................9
9. Warranty ..............................................................................................10
Owner’s Manual Ver. 1.0 / December 2017
© Mytek 2017
The Brooklyn AMP rmware can be easily updated via Mytek USB Control Panel. As the rmware is updated, Mytek will be posting new rmware releases in the support / download section on Mytek website. Firmware may alter details of Mytek operation and consequently there will be periodic updates to this manual. For news, driver updates, technical
support, tips and further product information please visit our website:
mytekdigital.com
Technical support issues are handled via our online support ticketing system. Please enter details of the ticket in the support/download section
on Mytek website.
148 India St.
Brooklyn, NY 11222
tel. +1 (347) 384-2687
Before installing and using your new Mytek Brooklyn AMP
please be familiar with all the information contained in this manual.
4 Mytek Brooklyn AMP User’s Manual 5
3. Package Content
The Brooklyn AMP (silver or black)
Power cord
• Owner’s manual
4. Features
With two types of input connectors (balanced XLR and unbalanced RCA) the Brooklyn AMP is suitable for a wide variety of applications and installed systemsAnalog outputs: RCA, balanced XLR, simultaneous
The AMP offers three operating modes: STEREO (where channels left and right operate independently), BI-AMP (Parallel) (where the unit outputs a mono source signal through twin amplier systems) and BRIDGE (operates as a single high-power amp =>600W monoblock) Built-in Attenuator: Choice of 1dB step analog attenuator, separate for main out and headphones, 1dB step digital 32 bit attenuator and purist relay bypass.
Short circuit protection, DC protection, under voltage protection, temperature protection, overload protection
Mytek Software accessible via usb micro allows for possible future rmware update and unit identication
LED logo power indicator
2. Introduction
Thank you for choosing the Brooklyn AMP from Mytek Digital and welcome to the Mytek
users’ community.
Brooklyn AMP is a reference power amplier with signature Mytek sound - musical, detailed and transparent. Its dual mono design breaks the sound quality spell associated with Class D and proves a well executed Class D circuits can challenge the best Class A and sound amazing. Amplier is packaged in miniature 1/2 rack enclosure and it’s small enough to t in a briefcase, yet powerfull to drive the largest speaker systems. It’s designed to be used as regular stand alone power amplier or to complement Brooklyn DAC for complete modern digital streaming and vinyl playback system.
Enjoy your new Brooklyn AMP!
All the best,
The Mytek Digital Team
6 Mytek Brooklyn AMP User’s Manual 7
1. RCA unbalanced analog inputs (right & left)
2. XLR balanced analog inputs (right & left)
Note that if you are using BRIDGE or BI-AMP mode, only the
left input channel is effective
3. Speaker output connectors
4. Mains power connector, 100-240VAC 50/60 Hz
5. Dipswitches enable different functions / operation modes
6. Trigger connector.
7. USB interface allows
5. Quick Start
5.1 Front Panel
1. Mytek backlit logo with its color and brightness user adjustable. Color follows the color of the Mytek Control Panel software.
2. On / Off button - press the button located at the front panel to switch the AMP on and off
5.2 Rear Panel
For best audio performance always use a high quality cables!
5.3 DIP Switches Conguration
There are eight dipswitches on the rear panel of the Brooklyn AMP. Each of them activates different function.
Upper position = off (default setting) Lower position = on
• 1 2nd off / on – power up trigger
3rd not used at the moment
4th not used at the moment
5th AMP gain (0 up, +6 dB down)
6th AMP mode (balanced = up, unbalanced = down)
Attention: User should switch the dipswitch to balanced mode
when using XLR connections or to unbalanced when using RCA.
Dipswitches 7th and 8th work together:
when 7 is up the AMP works in a regular stereo mode
when 7 is down the AMP mode depends on dipswitch #8 setting;
when 8 is up the AMP works in Bi-amp mode.
when 8 is down the AMP works in a Bridge mode.
6. OPERATING MODES and their settings
STEREO (default mode) - channels left and right operate independently as with a conventional
stereo amplier. The right input channel goes to the right output channel, and the left input channel goes to the left output channel.
BRIDGE (two units of Brooklyn AMP are required)– two amplier channels are internally connected in such a way that twice the output power is available. Settings: dipswitches 1, 7, 8 in lower position. Input signal should be connected to left input either XLR or RCA. The speaker should be connected to plus, red inputs. In a bridge mode actually left plus is a plus indeed, right plus is a minus. Black connectors remain unused.
BI-AMP - the left input channel signal is output through both: the right and the left output. The right input channel does not function in this mode. Settings: dipswitches 1, 7 in lower position. Input signal should be connected to left input either XLR or RCA. The speakers should be connected to minus (black) and plus (red) outputs.
Attention: Do NOT connect cables to XLR and RCA inputs at the same time! It could cause a damage of your Mytek Brooklyn AMP.
8 Mytek Brooklyn AMP User’s Manual 9
7. USB
Brooklyn AMP can be controlled by using Mytek Control Panel application. To downlad and install the software please visit our support page: https://mytekdigital.com/hi/support/
8. Firmware update Windows and OS X
The current revision of the Brooklyn AMP rmware is shown in the MytekControl „General” tab.
The rmware can be updated by using USB2 port and Mytek Control Panel application. It does not require installed USB2 driver (PC). To download the current rmware please visit:
mytekdigital.com
Follow the steps below to update the rmware:
1. Download the latest rmware (*.mfb) le from mytekdigital.com
2. Click „Load rmware le” button and browse to the new rmware le then click „Open”.
3. Press the „Update” button to conrm uploading the rmware le to device’s memory.
4. Conrm your choice by clicking „Yes” when warning dialog appears. A progress bar will indicate
when the ash process is nished.
5. When the update is nished the the AMP will be switched off. To switch it on press the button on the front panel once.
9. Technical Specication
Output Power in stereo and bi-amp mode,1kHz @ 8, 4, 2 Ohm: 2x 300W Output Power in bridge mode, 1kHz @ 8, 4Ohm: 1x 600W Burst Output Power in stereo and biamp, 1kHz @ 8, 4, 2 Ohm: 2x 500W Burst Output Power in bridge mode, 1kHz @ 8, 4 Ohm: 1x 1000W
Output voltage in stereo and biamp mode: 70Vp/140Vpp unloaded Output voltage in bridge mode: 140Vp/280Vpp unloaded
Frequency Response -3dB: 10 Hz - 30 kHz: +0/-0.25 dB
Upper bandwidth @ -3dB for RL = 8 Ohm: 85kHz Upper bandwidth @ -3dB for RL = 4 Ohm: 65kHz Upper bandwidth @ -3dB for RL = 2 Ohm: 44kHz
THD+N (1kHz @ 1W): 0.002 % THD+N (typical): < 0.04 % (20 Hz - 20 kHz, 8 Ohm load, 3 dB below rated power) Signal To Noise-Ratio: > 121 dB (A-weighted, 20 Hz - 20 kHz, 8 Ohm load)
Input gain control: 23dB (default), 29dB dip switch selectable Input Impedance: 10 kOhm
Operation Voltage Universal Mains: 85-265V
Protection Circuits: short circuit protection, DC protection, under voltage protection, temperature protection, overload protection
Dimensions: WxDxH:8.5x9.5x1.74” / 216x241x44mm Weight: 6lbs / 3 kg Warranty: 2 years
10 Mytek Brooklyn AMP User’s Manual 11
10. Warranty
Each individual Brooklyn AMP undergoes comprehensive quality control and a complete test before shipping. This Brooklyn AMP is warranted by Mytek to the original purchaser against defects in workmanship and materials used in manufacture for a period of two years from the date of purchase.
Faults due to customer misuse, unauthorized modications or accidents are not covered by this warranty. Removal of serial number sticker voids warranty. No other warranty is expressed or implied.
If you suspect that your product is faulty, please contact the place of purchase or alternatively: in the U.S.: Mytek US Ofce in New York, in The EU: Mytek EU Ofce in Warsaw, Poland. Prior to shipping for warranty services the customer or dealer must obtain an RMA number from Mytek for warranty services. Units sent without RMA number will not be accepted.
Mytek extends affordable repair service for all units manufactured to date that are less than 10 years old. Older equipment may or may not be repaired depending on the availability of parts.
Important Safety Information
Read, keep and follow these instructions.
Connect all your devices before powering the unit.
Do not expose this device to moisture, rain and liquid of any kind.
Clean only with dry cloth.
If any form of liquid or a forin object enter the device switch it off and unplug it from the power
source. Do not operate device until the foreign object is removed or the liquid has completly dried. If in doubt please contact Mytek Digital.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including ampliers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specied by the manufacturer.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury
from tip-over.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Refer all servicing to qualied service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Warning
Excessive sound pressure from speakers and headphones can cause hearing loss. In order to use this product safely, avoid prolonged listening at excessive sound pressure levels.
For the customers in the U.S.A.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
You are cautioned that any changes or modications not expressly approved in this manual could void your authority to operate this equipment.
All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This product with the CE marking complies with the EMC Directive issued by the Commission of the European Community. Compliance with this directive implies conformity to the following European standards:
EN55103-1 : Electromagnetic Interference (Emission)
EN55103-2 : Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following Electromagnetic Environments: E1 (residential), E2 (commercial and light industrial), E3 (urban outdoors), E4 (controlled EMC environment, ex. TV studio).
Information on Disposal for Users of Waste
Electrical & Electronic Equipment(private households).
The Wheelie Bin symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on
human health and the environment.
To properly dispose harmful substances and recycle the product, the user is obliged to return it at the point of collection of electrical and electronic equipment waste. For more information please contact your
local authorities, waste disposal units or retailer.
Loading...