Mystery Electronics, LLC
6438 Morton Road
Greenbrier, TN 37073
800 798 2256 sales
615 643 8460 voice
615 643 8464 fax
www.mysteryelectronics.com
TechNote TN12
Rev: 2
RE: Installation Instructions for BB1000, BB2000 and BB3000 Backboxes
Important Note:
Mystery Electronics backboxes are UL listed and conform to all applicable N.E.M. A. Standards. While locally available boxes may
seem acceptable as substitutes, there are differences in certain critical dimensions. For a fast and easy installation and to avoid
costly onsite rework, the user is strongly cautioned to use only Mystery Electronics backboxes. The y are proven to be the lowest
cost alternative.
Fig.1 Dimensions: nominal in inches - see also footnotes below
F
A B C D E
Ú
Ú
Ú Ú
Ú Ú
Y Y
Z
C
D
F
BB1000
BB2000
6 6 6
12.5 6 4
BB2000D3 12.5 6 6
BB3000
12.5 12 4
BB3000D3 12.5 12 6
E
G
Knockout patterns: Trade size - patterns same on opposite sides.
X = ½ & ¾” Y = ¾ & 1” Z = 1 & 1¼”
pattern Ú pattern
A
X X
Y
X X
B
1.621.62
Notes:
1) Low voltage conduits below line indicated by F -
see Fig.1
2) R Option (120VAC duplex receptacle) conduit below line indicated by G - use X k.o.’s only - see Fig.1
3) Conduits to 3” use extra depth backboxes - bottom of k.o. at .4” from bottom of box
4) Backbox shall be mounted such that cover of box shall be not less than 1/2” or not more than 1” below
finished floor to allow proper depth to mount appropriate FMCA series floor box.
5) All conduits shall enter backbox at or below the minimum distances indicated at ‘F’ & ‘G’. -
see Notes 1 & 2
6) On projects where fork lifts and other heavy equipment are present during construction, cover the backbox
with adequate material (steel plate or equal) affording maximum protection as required.
7) Backboxes installed in floating floors require special consideration – contact factory for details.
Wooden construction -
see Fig.2
As floor box may be subjected to long-term traffic and occasional heavy loads, it is strongly recommend that firm
attachment of the backbox to the framing be made with four (4) each #8 or larger screws fastened on at least two
(2) planes (sides), minimum. Nails will not offer long term installation integrity as they work loose over a very short
time period. Additional blocking or framing may be required to provide solid attachment of the backbox as per
Notes & details herein.
When placement adjacent to structural framing is not possible, blocking must be placed at the sides of the hole
that is cut for the backbox. Blocking of 1” x 2” minimum must be screw attached to the floor decking on each side
of the hole. Blocking should be a few inches longer than the dimension of the hole on the two sides that are
parallel to the hinge of the FMCA unit. Feed each strip down into the cutout hole and pull it up against the
underside of the floor. Place #8 or larger flat head wood screws on 3” centers thru the floor 1” back from edge of
hole along each side into the blocking. Secure backbox to blocking as above. When FMCA unit is installed, the
floor will be clamped securely between the FMCA cover and the blocking strip.
G2
1
4.5 1.25
2.5
2.5
2.5
2.5
1.25
1.25
1.25
1.25
1.621.62 1.88 1.88
AAA002JA23 p.1/2

Fig.2: Wood Floor
1/2"Min. 1"Max. (Note 4)
Floor Decking
Backbox
Joist
Carpet
(Note 5)
Fig.3: Concrete Floor
1/2"Min. 1"Max. (Note 4)
Plywood
Backbox
Concrete
(Note 5)
Concrete construction -
see Fig.3
The Mystery Electronics FMCA Series are not recommended for unprotected outdoor or indoor wet, damp or
severe weather locations. Certain local building codes may require that the backbox be coated with pitch for
below ground applications. This can be done by spraying the outer surface of the box with automotive
undercoating material available in spray cans from most auto parts or discount department stores (Wal-Mart,
etc.). It is additionally advised that the contractor close all open cracks with packaging tape, duct tape, or similar
to prevent concrete slurry from seeping into backbox during the concrete pour.
To automatically adjust for proper backbox depth before concrete is poured, attach a piece of ½” plywood of the
same dimension as the backbox to the top of the box with screws. Screed concrete flush to the top of the
plywood. This will result in the box being at the proper depth of ½” below the finished concrete surface as per
Notes & details herein. Adjust depth accordingly when composite floor structures and materials are built over
concrete.
R Option requirements -
see also Note 2
When an R option (120 VAC duplex receptacle) is specified, the power circuit in a ½” conduit is bro ught into the
side of the backbox at any of the ½” knockouts, pre-punched for the purpose (see Fig.1). The R option of the
FMCA unit comes with all needed hardware and is equipped with a 16” flexible metallic conduit terminated with a
straight flex connector. This pigtail is then connected to the power conduit with a ½” rigid coupling.
Bringing the power conduit into the bottom of the backbox should be avoided if possible, as extreme care is
needed to assure the proper clearances for the FMCA unit are maintained. When this is the only alternative, the
straight flex connector must be replaced with a 90-degree flex connector and the aforementioned ½” rigid
coupling must be cut down to ½” in length to provide proper clearance for the FMCA unit. The short threaded ring
in the center of a ½” ‘Ericson’ (Appleton EC50 or equal) three piece coupling or a ¾ x ½ reducing bushing can
usually be used as a substitute.
A ½” conduit for the power circuit is recommended. A ¾” conduit can be allowed, provided a ½ x ¾ male adapter
is used to mate the power conduit to the backbox. This will eliminate extensive field modification of the R option
during installation of the FMCA unit.
Leave 24” of the power circuit conductors in the backbox at rough-in to allow connection to R option pigtail.
AAA002JA23 p.2/2