Myson ULOW-E2, FINESSE, PREMIER, SELECT, PREMIER HE Technical Manual

...
MYSON
heatingthroughinnovation.
PANEL RADIATORS.
NOVEMBER 2013
1. ULOW-E2 04
l
General Specifications 05
l
Technical Information 06
l
Heat Outputs & Accessories 07
2. FINESSE 08
l
General Specifications 09
l
Technical Information 10
l
Heat Outputs & Technical Characteristics 11
3. PREMIER Compact 12
l
General Specifications 13
l
Technical Information 14
l
Heat Outputs 18
4. PREMIER HE 12
l
General Specifications 13
l
Technical Information 15
l
Heat Outputs 20
5. PREMIER Metric (2 & 4 Tap) 12
l
General Specifications 13
l
Technical Information 16
l
Heat Outputs 22
6. SELECT Compact 12
l
General Specifications 13
l
Technical Information 17
l
Heat Outputs 26
7. LST 28
l
General Specifications 29
l
Technical Information 30
l
Heat Outputs 31
l
Controls 32
8. Heating Controls 33
l
Valves 34
03
Contents
General Specifications
Approval and Certification
All MYSON ULOW-E2 radiators are manufactured and tested to BS EN 442. Every radiator carries the BS Kitemark which certifies independent approval of heat output and verifies production under a quality system to BS EN ISO 9001.
All MYSON ULOW-E2 radiators carry a two year guarantee from date of manufacture against defects caused by faulty materials or manufacture.
Paint Finish
Every MYSON ULOW-E2 radiator is primer coated.
An epoxy polyester finishing coat in white (RAL 9016) is applied to all front and rear surfaces allowing the radiator to be fitted without further painting
*
.
Packaging
Every MYSON ULOW-E2 radiator is wrapped in paper and has strong cardboard corners. The front side of the radiator is double protected with an additional hard cardboard and then wrapped together in shrink wrap. Each radiator is clearly labelled with size and type, and packed with the appropriate number of brackets. An assembly instruction, and instruction manual is also included.
Fixings
All MYSON ULOW-E2 radiators are supplied with concealed wall mounting brackets. The table of dimensions gives further details.
For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED
THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
PLEASE NOTE: The fixing materials provided are only intended for installation on walls made of solid wood, bricks, concrete or on timber-frame stud walls where the fixing is into the timber. All walls being considered should have no more than a maximum of 3mm wall finishing. For walls made of other materials, for example hollow bricks, please consult your installer and/or specialist supplier. ONCE AGAIN,
IF YOU ARE UNSURE, IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
Application
MYSON ULOW-E2 radiators are for use on two pipe pumped
indirect domestic and commercial central heating installations, with a maximum working temperature of 60
o
C. The system should be designed in accordance with BS EN 12828:2003 or BS EN 12831:2003 as appropriate, with particular care taken to avoid air entry or water discharge.
We do not recommend the use of single feed indirect cylinders, as the possibility of aeration due to water interchange may lead to corrosion.
The installation work must be carried out in accordance with recognised good practice, and precautions taken to avoid contamination which could lead to corrosion. If a corrosion inhibitor or other water treatment is to be used, the Manufacturer’s Instructions must be strictly followed.
The recommendations of BS 7593, Code of Practice for treatment of water in domestic hot water central heating systems, should be followed where appropriate.
Safety Precautions
Radiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of a radiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and users should ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installers and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be given to installing low surface temperature radiators, or to placing guards in front of the radiators.
Electrical Data
All ULOW-E2 models require an electrical supply of 220-240V­50Hz.
BS EN 442
2
2
2
*Specification is correct for white version only.
05
ULOW-E2 General Specifications
ULOW-E2
Length
(mm)
Weight (kg)
Water
Content (l)
No. of Fans Comfort Boost
Power
(W)
Sound Pressure (dBA) (at 2.5m)
B M8
B M6
A M8
A M6
Sound levels tested in accordance with ISO 3741.
07
ULOW-E2 Heat Outputs & Accessories
The ULOW-E2 comes with a thermostatic radiator valve as standard. The twin entry valve and nut & olive pack should be purchased separately.
Order CodeProduct
Twin Entry Valve (Straight)
Twin Entry Valve (Angled)
Twin Entry Reversible Flow Valve (Straight)
Twin Entry Reversible Flow Valve (Angled)
Nut & Olive Pack (10mm)
Nut & Olive Pack (15mm)
E2TEVS
E2TEVA
E2TERVS
E2TERVA
E2NOP10
E2NOP15
E2TEVS
E2TEVA
E2TERVS E2TERVA
E2NOP10 / E2NOP15
Operating Pressures
Every MYSON ULOW-E2 radiator is tested to a pressure of 10 bar and is suitable for a working pressure of up to 13 bar.
Maximum operating temperature: 60°C (because of the fan units).
Nominal Height 600 mm
ULOW-E2 - Type 22
(with factory fitted top grille and side panels)
400
600
800
1000
1200
1400
1600
Nominal
Length
(mm)
Static
Comfort
Boost Static
Comfort
Boost Static
Comfort
Boost Static
Comfort
Boost Static
Comfort
Boost Static
Comfort
Boost Static
Comfort
Boost
Operation
Mode
Heat Outputs
@ ΔT 10°C
Heat Outputs
@ ΔT 20°C
Heat Outputs
@ ΔT 30°C
Heat Outputs
@ ΔT 40°C
Heat Outputs
@ ΔT 50°C
Watts Btu/h Watts Btu/h Watts Btu/h Watts Btu/h Watts Btu/h
Order Code
(White)
*
74 252 184 628 314 1071 459 1566 616 2102 125 427 272 928 430 1467 595 2030 766 2614 ULOW 040 147 502 317 1082 498 1699 686 2341 879 2999 111 379 276 942 471 1607 688 2347 923 3149 188 641 409 1396 647 2208 895 3054 1151 3927 ULOW 060 220 751 475 1621 746 2545 1027 3504 1316 4490 148 505 368 1256 628 2143 917 3129 1231 4200 250 853 545 1860 862 2941 1192 4067 1534 5234 ULOW 080 294 1003 634 2163 996 3398 1371 4678 1757 5995 185 631 460 1570 785 2678 1147 3914 1538 5248 312 1065 681 2324 1077 3675 1490 5084 1917 6541 ULOW 100 367 1252 792 2702 1244 4245 1712 5841 2194 7486 222 757 552 1883 942 3214 1376 4695 1846 6299 374 1276 817 2788 1292 4408 1787 6097 2299 7844 ULOW 120 440 1501 950 3241 1492 5091 2054 7008 2632 8980 259 884 644 2197 1099 3750 1605 5476 2153 7346 436 1488 953 3252 1507 5142 2085 7114 2682 9151 ULOW 140 514 1754 1109 3784 1741 5940 2398 8182 3073 10485 296 1010 736 2511 1256 4285 1834 6258 2461 8397 499 1703 1090 3719 1723 5879 2384 8134 3067 10465 ULOW 160 587 2003 1267 4323 1989 6786 2739 9345 3510 11976
*For the black model, simply add a ‘B’ to the end of the order code.
ULOW-E2
Accessories
Nominal Height
600
(mm)
143143
M6
157.5452.5
M8
B (mm) A (mm) B (mm)A (mm)
600mm Wall Bracket
Dimension Y =
Overall Length
2
09
FINESSE General Specifications
FINESSE
General Specifications
Approval and Certification
MYSON FINESSE electric panel radiators
are produced under a quality system to BS EN ISO 9001.
MYSON FINESSE electric panel radiators carry a ten year guarantee from date of manufacture against defects caused by faulty materials or manufacture except for the electrical and electronic components that are covered by a two year warranty.
Paint Finish
All FINESSE electric panel radiators are de-greased, phosphated and primer coated. An epoxy polyester finishing coat in white (RAL 9016) is applied to all front and rear surfaces allowing the radiator to be fitted without further painting.
Packaging
Every MYSON FINESSE electric panel radiator is packed in robust cardboard packaging specially designed to ensure that the product reaches you in perfect condition. Each radiator is clearly labeled with size and type, and packed with the appropriate number of brackets.
Fixings
MYSON FINESSE electric panel radiators are supplied with
concealed wall mounting brackets. Please refer to the Bracket Positions and Dimensions on page 10 for details. For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED
THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
PLEASE NOTE: The fixing materials provided are only intended for installation on walls made of solid wood, bricks, concrete or on timber-frame stud walls where the fixing is into the timber. All walls being considered should have no more than a maximum of 3mm wall finishing. For walls made of other materials, for example hollow bricks, please consult your installer and/or specialist supplier. ONCE AGAIN,
IF YOU ARE UNSURE, IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
Accessories
Touch up Paint
A handy 12ml container of touch up paint with integral brush applicator in RAL 9016 is available on request.
RF Programmer
The MYSON FINESSE radiator can be used as a stand alone radiator or can be connected to a radio frequency programmer via a wireless wall receiver.
Application
All installation work and wiring work related to the radiators, thermostats and programmers must be carried out only when de-energized. The appliance should be commissioned by qualified professionals only. Make sure to adhere to valid safety regulations. Any repairs or maintenance within the warranty period should be carried out only by approved service engineers confirmed by MYSON.
Safety Precautions
Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. Installers and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be given to placing guards in front of the radiators.
In order to avoid overheating, do not cover the radiator. “Do not cover” means that the radiator must not be used for drying clothes, for example, by placing them directly on the radiator.
BS EN 442
2
2
2
11
FINESSE Heat Outputs & Technical Characteristics
FINESSE
l
MYSON FINESSE is class 2 and splash resistant (IP44).
l
MYSON FINESSE complies with the European Directive 2004/108/EC (CE Marking on all appliances).
Length (mm)
Technical Characteristics Optional Extra - RF Programmer
Waste Disposal According to The WEEE Directive (2002/96/EC)
Safety Clip-on Brackets
300 500
135
90
205
163
Nominal
Height (mm)
C
D
C
D
L
Waste disposal according to the WEEE Directive (2002/96/EC). The symbol on the product label indicates that the product may not be handled as domestic waste, but must be sorted separately. When it reaches the end of its useful life, it shall be returned to a collection facility for electrical and
electronic products. By returning the product, you will help to
prevent possible negative effects on the environment and health to which the product can contribute if it is disposed of as ordinary domestic waste. For information about recycling and collection facilities, you should contact your local authority/municipality or refuse collection service or the business from which you purchased the product. Applicable to countries where this Directive has been adopted.
Nominal Height 300 mm
FINESSE
Double Panel “Xtra”
500
800 1000 1300 1600 2000
Nominal Length
(mm)
Heat Outputs
(Rated Watts)
Order Code
500 FE 30 DX 50
750 FE 30 DX 80 1000 FE 30 DX 100 1250 FE 30 DX 130 1500 FE 30 DX 160 2000 FE 30 DX 200
Nominal Height 500 mm
400
500 650 800 950
1250
500 FE 50 DX 40
750 FE 50 DX 50 1000 FE 50 DX 65 1250 FE 50 DX 80 1500 FE 50 DX 95 2000 FE 50 DX 125
0.1°C
-10°C + 50°C
+5°C + 30°C
PWM
Class 1 – IP44
230 VAC – 50 Hz
~3.5 W
TRIAC 230 VAC 8A
l
EN 60730-01
l
EN 61000-6-1
l
EN 61000-6-3
l
EN 61000-4-2
l
LV Directive 2006/95/CE
l
EMC Directive 2004/108/CE
Measured temperature precision
Operating temperature
Setting temperature range
Control characteristics
Electrical protection
Power supply
Controls consumption
Output
The thermostat has been designed to comply with the following Directives and Standards.
l
Install and plug the radiator into a switched fuse spur along with the wireless wall receiver. NB: The RF programmer will not work without the wireless wall receiver.
l
Install the RF programmer in a suitable location.
l
Connect the wireless wall receiver to the RF programmer using the manufacturers instructions on both products.
PLEASE REFER TO THE MANUFACTURERS MANUAL FOR FULL INSTALLATION INSTRUCTIONS.
Switched Fuse Spur*
RF Programmer
Wireless Wall Receiver
Wall
.
.
.
.
Wall
500mm Wall Bracket
300mm Wall Bracket
Step 1 Step 2
*When installing in a bathroom or wet room, please refer to the FINESSE Installation, Operating & Instruction Manual.
Loading...
+ 12 hidden pages