Myson SELECT, T6, DECOR, COLUMN, BENCH Technical Manual

Page 1
01.11.2011
MYSON
heatingthroughinnovation.
Column Radiator Series
Page 2
02
COLUMN.
MYSON COLUMN radiator's aesthetically sophisticated design was conceived for technologically superior heating. Their design form makes them suitable for a wide range
of architectural applications from retro to modern.
Contents/Warranty
03 04
05
06 07 08
12
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims
MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS -- SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
Painted finishes will not peel or flake from the surface of the radiator
The body of the radiator and its welded joints will not leak when the product is properly installed and maintained according to Myson's instructions.
What is not covered:
Rust occurring from improperly sealed threaded connections or oxygen corrosion
Electrolytic corrosion caused by failure to flush the system properly after initial installation
Contents
What is covered:
Important information Product description Model overview / connection dimensions
Piping & rough-in
Wall bracket position information Optional Floor bracket information
Heating outputs / weights / water content
Piping arrangements Valve selection
Heat output factors / System start - up
13
9 - 10
11
Page 3
Important Information 03
BEFORE YOU BEGIN
SAFETY PRECAUTIONS
Rad
iators are hot when in use, and as such, present a
risk of burns
to
users
on
prolonged
contact.
The
temperature
of
a
radiator
is
dependent
on
the
temperature
of
the
system
water,
as
set
by
the
system installer or user. Installers and users should ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installers and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be given to installing low surface temperature radiators, or to placing guards in front of the radiators.
For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements
need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED
PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
INTRODUCTION
The Myson Column Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the Column Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness and dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTION
Step 1 Read this entire instruction manual thoroughly before beginning installation. Step 2 To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all
the instructions carefully .
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATION
Myson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom­mended for gravity systems. DO NOT USE STEAM IN THESE RADIATORS.
INSPECT FOR DAMAGE NOTE: Inspect materials for concealed shipping damage. You only have 10 days to file a freight claim. If items are
damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESS
Unpack the radiator carefully to avoid damage or loss of parts. The Column Radiator will come with the following parts:
• Wall mounting bracket kit
• Plastic inserts for noise suppression
• Stainless steel solid plug
• Vent plug
IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/ herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
DESIGN AND LAYOUT CONDITIONS
Myson Column Radiators should only be used with a properly sized recirculation pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Column radiator is below a window where it can minimize downdrafts from glazed areas.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Page 4
Radiators
2 - COLUMN:
Standard Heights: 18, 24, & 79 inches (45, 60, & 200 cm)
Coatings:
1. Undercoat: electrophoretic, using water-soluble paints, conforming to
DIN 55900 part 1, stoved at 329
° F;
2. Finish: electrostatic powder coating, conforming to DIN 55900 part 2, i
n a state-of-t
he-art facility. (On request, and at a supplementary charge, a range of RAL and sanitary ware colours can be offered.) This particularly
r
obust coating is stoved at an object temperature of
356° F
.
Packaging: 1. Cardboard packaging
2. Edge protection
3. Shrink foil
COLUMN product description
Quality certificates
MYSON offers its customers strong brands that meet highest quality standards. All the production sites’ production processes are certified ac­cording to ISO. The quality and perfor­mance specifications of the convectors and heating panels have been verifi ed by recognised European institutions.
The standards that the quality certifi ­cates require us to maintain give you security, the best heating performance and premium product quality. For the MYSON warranty conditions, please refer to the table of contents page of this manual.
Strong brands of the highest quality
Connections: 4 x internal thread G 1/2“ BSP, welded-in for supply and return. Vent and drain plugs (or dummy plug) are included
Maximum positive operating pressure:
145 psi
Maximum operating temperature:
max.
72psi
max.
04
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
PRODUCT DESCRIPTION
12 - 3045
Overall Height [cm]
Number of Columns
Number of Sections
Additional sizes and models are available as special order
Tested to positive pressure:
188.5 psi
248° F
5
5
5
Manufacture
MYSON COLUMN radiators are manufactured using a unique
laser
welding proce
ss that virtually eliminates
the visible
welding
points
associated
with
the
traditional
methods
of
manufacturing
this
type
of
radiator.
The
clean
finish
significantly
enhances the
aesthetic qualities of the radiator.
Tube Details
Precision, D-
profile steel
tube is used
for
all
outside
surfaces
which
ensures
high
outputs
and
soft,
rounded
edges
for
maximum
safety.
All
MYSON
COLUMN radiators are
manufactured and tested to EN 442.
Paint Finish
Every MYSON COLUMN radiator undergoes a multi-stage pre-treatment process followed by an epoxy polyester primer coating. A stoved
epoxy
polyester powder coat in white (RAL
9016) is applied to all front and rear surfaces
allowing the MYSON COLUMN to be fitted without further painting.
MYSON COLUMN radiators carry a 5 year guarantee against defects caused by faulty materials or manufacture.
3 - COLUMN:
Standard Heights: 12, 18, & 24 inches (30, 45, & 60 cm)
4 - COLUMN:
Standard Height: 24
inches
(60 cm)
See pages 9 & 10 for standard number of sections and outputs
ABOVE EXAMPLE: 12 Sections, 3 Column, 18"High
Page 5
COLUM
N model overview / connection dimensions
Dimension and Mounting Quick Reference
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
05
Length equals the number of sections times 2" Example:
56 sections times 2"
equals 112"
2"
1"
1 1/4"
1 1/4"
All tappings are 1/2" BSPT
C
L
LKD16AN
C
L
1 3/4"
1 3/4"
Shown with DAV12 and LKD16AN valves. See page 12 for additional valve choices .
DAV12
4"
3/4"
1-3/16"
2-5/16"
3-1/4"
5/8"
2"
1/2"
Position 2
Position 1
Column Radiator Wall Brackets
4 Column
5 1/2"
3 Column
4"
2 Column
2 1/2"
Pipe centers from finished wall are dependent on which mounting slot is selected on the mounting bracket and the number of columns.
2 Column 3 Column 4 Column
Position 1 Min: 21/2"
31/4"
4"
Position 2 Max:
27/8"
35/8"
43/8"
To obtain pipe centers using Myson valves multuply the number of sections by 2" and add 3.5". Example: A 12 section radiator would be 12 x 2"+ 3.5" = 27.5"
MYSON COLUMN RADIATOR ROUGH -IN SPECIFICATIONS
Page 6
COLUMN piping & rough-in
H and V models
Suitable for mono-flo, home run or 2-pipe systems
Rough-in dimension shown at right is for a TRV and a LKD valve or a pair of LKD valves. When using FF valves add 3-5/8" to overall length.
Recommendation: Radiator tappings and valve spuds are 1/2"BSP. Professional expertise is required when sealing these "straight" threads. Failure to properly seal the connections will result in leaks resulting in property damage.
NOTE ! Myson is not responsible for damage resulting from improper workmanship.
NOTE ! Rough-in information is given for Myson control valves. Valve specifications vary by manufacturer. Myson will not be responsible for damage or repair of property resulting from the use of non-Myson valves.
06
Overall Length + 3-1/2"
LKD16AN
FF16WAC
TRV
All installations require 2 valves per radiator
All valves are ½” BSP thread for connection to
the radiator and ½” NPT thread for connection to the system (also includes compression nut and ferrule for connection to ½” copper)
Valves are available in 3 basic patterns: angle, straight, and inverted angle (TRV only)
Basic Installation: use 2 – LKD16AN (angle) or LKD16SN (str
aight) manual valves, nickel plated with
screwdriver stops and caps
Basic upgrade: use 1 - FF16WAC and 1 - FF16LAC manual valves, angle only, chrome plated
with white handles (FF16WAC is adjustable for balancing, FF16LAC is fixed open but can be closed for service)
TRV (thermostatic radiator valves) are available for automatic temperature control of individual radiators: available in 3 body patterns,
with or without thermostatic head (sensor), use in conjunction with LKD or FF
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
NOTE: See page 5 or 7 for rough-in from finished wall to pipe centers.
See page 12 for additional valve information
All MYSON COLUMN radiators are manufactured with an internal baffle. The tapping with the baffle is identified with a RED plastic cap, all others being BLUE. It is important that the supply inlet is connected to
the
tapping identified in RED.
MYSON COLUMN radiators are suitable for the use of BBOE (Bottom Bottom Opposite
End), TBSE (Top
Bottom Same
End) and TBOE (Top Bottom Opposite End) connections. TTOE (Top Top Opposite End) connections cannot be used.
A
ll systems must be designed with
suitable pipe sizing
and
with adequate
pump head. Failure to do this may lead to trapped air and cold spots because of insufficient pressure and water flow will not drive the air from the radiator. The taller and more tubes a radiator has, the more likely this is to happen.
The installation work must be carried out with precautions taken to avoid
contamination
which
could
lead
to
corrosion.
If a corrosion
inhibitor
or other water treatment is to be used, the Manufacturer’s Instructions must be strictly followed.
The MYSON COLUMN radiator's large diameter steel tu
be contruction ensures a negligible pressure drop through the radiator. The pressure drop through the radiator can be ignored in the design of most hydronic systems.
Page 7
2" 13/16"
5
/8"
3
/4"
13
/32"
3
/16"
1
/4"
15
/64"
9
/16"
19
/32"
9
/64"
9
/16"
11
/16"
3
/16"
11
/16"
1
/2"
13
/16"
3
/8"
2
5
/
16
"
3
1
/
4
"
11
/32"
1
/4"
25
/32"
Radiator Bracket
Angle Wall
Bracket
insert
Ensure tight
fit here
19/32"
27/
16"
7
/16"
A
(see table below)
25
/32"
13/16"
7
/16"
3
/4"
1"
1
/2"
15
/32"
Wall &
Bracket
Wall &
Radiator
A = Distance between Wall & Center
Wall Bracket &
Radiator Bracket
25/32"
7
/16"
17/32" 2 1/2" 3 1/4"
4"
13/16"
7
/16"
1 5/8" 27/8" 3 5/8"
4 3/8"
2 column 3 column 4 column
Operating Pressures
Every MYSON COLUMN radiator is tested to a pressure of 13 bar (188.5 psi) and is suitable for a working pressure of up to 10 bar (145 psi).
Radiator Brackets
Floor Bracket SK
Mounting Brackets (supplied with every radiator) - Wall Brackets
Fixing Brackets - Clamped Floor Bracket FK
COLUMN Mounting Bracket Detail
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
07
Page 8
39/16"
2
15
/
16
"
4
3
/
32
"
5
/
16
"
Dimensions of base-plate
for Floor Bracket SK
Two-part cover for base-plate in white plastic 45/16" x 55/16"
Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016.
Includes:
- 3mm thick base-plate for fixing to either finished or unfinished floor
- upright support 35 x 10 x 1.5mm, fixing set with adjustable bracket, security fixing, anti-vibration insert
- adjustable bottom support with spacer and security fixing, anti-vibration insert, white plastic end stop for top of upright.
Height of
Upright
Order Code
18"
24"
30"
Base-Plate Cover
Height of
Radiator
12"
18"
24"
5
0-20046
5
0-20061
5
0-20076
COVERSK
Floor Bracket SK (Optional)
COLUMN Floor Bracket Detail
49/16"
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
The table on the right gives recommendations for the number of brackets to be used with each radiator.
The strength of the wall should be checked for its load-bearing capabilities before installation.
Type
2 to 4 Column
Number of Sections
0 - 20
21 - 40
4 6
Up to 39” Height: Wall ­Mounted Angle Brackets - RW Radiator Bracket - RH
4
6
Floor Mounting Floor bracket - SK
2 3
4 6
Over 39” Height: Wall ­Mounted Angle Brackets - RW Radiator Bracket - RH
4
6
08
Page 9
Height 24in
Height 18in
Height 79in
Architecture Range - Bench Radiator
4 COLUMN
Height 1
2in
Height 1
8in
Height 2
4in
Height 24in
H
L
4 COLUMN3 COLUMN2 COLUMN
2
1
/
2
in
4in
5
1
/2 in
Fixing Brackets
Product Code: FK1021 Product Code: COVERFK
COLUMN Sizes & Outputs
Length inc. seat Height inc. seat Depth inc. seat Output Output
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
NOTES:
1. All dimensions are nominal.
2. Heat outputs are based on
1800F AWT and 680F EAT (mean water to air
temperature of 1120F)
3. For heat outputs at other temperatures see page 13.
2 COLUMN
No. of Sections
Weight (lbs)
Ou
tput (Btu/h)
Order Code
24
12
19.8
1485
12 - 2045
32
16
26.5
1980
16 - 2045
40
20
33.0
2474
20 - 2045
47
24
39.6
2969
24 - 2045
55
28
46.2
3464
28 - 2045
72
36
59.4
4454
36 - 2045
24
12
25.9
1925
12 - 2060
32
16
34.6
2567
16 - 2060
40
20
43.2
3209
20 - 2060
47
24
52.0
3850
24 - 2060
55
28
60
.5
4492
28 - 2060
12
6
41.4
3006
6 - 2200
16
8
55.2
4008
8 - 2200
20
10
69
.0
5010
10 - 2200
24
12
82.8
6012
12 - 2200
30
15
103.5
7515
15 - 2200
Water Content (gals)
1.68
2.24
2.80
3.36
3.92
5.00
2.10
2.80
3.50
4.20
4.90
3.00
4.02
5.02
6.02
7.53
Length (in)
3 COLUMN
No.
of Sections
Weight (lbs)
Output (Btu/h)
Order Code
32
16
27.5
2380
16 - 3030
40
20
34.4
2975
20 - 3030
56
28
48.2
4265
28 - 3030
72
36
62.0
5355
36 - 3030
24
12
29.6
2674
12 - 3045
32
16
39.5
3565
16 - 3045
40
20
49.4
4456
20 - 3045
48
24
59.3
5347
24 - 3045
56
28
69.3
6439
28 - 3045
24
12
41.4
3566
12 - 3060
32
16
55
.2
4
755
16 - 3060
40
20
69
.0
5944
20 - 3060
48
24
82.8
7132
24 - 3060
56
28
103.5
8321
28 - 3060
Water Content (gals)
2.42
3.02
4.23
5.44
2.41
3.22
4.02
4.83
5.63
3.
00
4.
02
5.02
6.02
7.5
3
Length
(in)
72
36
88.9
8021
36 - 3045
7.24
No.
of Sections
Weight (lbs)
Output (Btu/h)
Order Code
24
12
51.6
4
213
12 - 4060
32
16
68.8
5618
16 - 4060
40
20
86.0
7022
20 - 4060
48
24
103.2
8
426
24 - 4060
Water Content (gals)
4.00
5.33
6.67
8.00
Length (in)
09
Page 10
Architecture Range - Bench Radiator
BEN
CH Sizes & Outputs
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
No. of Sections
Weight (lbs)
Output (Btu/h)
Order Code
53 x 19 x 14
5
75
3528
23-05-6100
53 x 21 x 14
6
8
7
4231
23-06-6100
61 x 19 x 14
5
85
4185
23-05-6120
61 x 21 x 14
6
99
5022
2
3-06-6120
73 x 19 x 14
5
1
46
6452
23-05-6150
73 x 21 x 14
6
1
61
7530
23-06-6150
85 x 19 x 14
5
1
72
7868
23-05-6180
85 x 21 x 14
6
1
90
9182
23-06-6180
9
3 x 19 x 14
5
1
86
8895
23-05-6200
Water Content
(gals)
3.75
4.49
4.41
5.28
4.52
6.50
5.34
7.64
5.90
Dimensions (in)
LxHxW
93 x 21 x 14
6
2
05
10383
23-06-6200
8.42
3"
1
3
/8"
Thermostat
H
14
9
/16"
11
13
/16"
5
5
/
16
"
A
15
/
16
"
5
5
/
16
"
1
3
/
16
"
2
3
/4"
2
15
/16"
3
15
/16"
Thermostat
1
/2" Valve Body
Detail "A"
Y
Radiator Length + 13
3
4
"
Technical Data
Radiator Length - 2
9
/16"
Radiator Lenth + 1
3
/8"
3
15
/16"
NOTE: All dimensions are nominal.
Radiator Length
39
3
/
8
39
3
/
8
47
1
/
2
47
1
/
2
59
1
/
16
59
1
/
16
70
7
/
8
7
0
7
/
8
78
3
/
4
78
3
/
4
Rough - in (cc)
36
13
/
16
36
13
/
16
44 11/
16
56
1
/
2
68
5
/
16
76
3
/
16
(in)
(in)
44 11/
16
56
1
/
2
68
5
/
16
76
3
/
16
X
10
Page 11
Typical hydronic system types
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
11
The following drawings are general examples.
Consult a certified heating professional for your specific application.
RADIATOR optional piping arrangements
Page 12
RADIA
TOR valve selection
Valve application
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
12
All installations require 2 valves per radiator
All valves are ½” BSP thread for
connection to the radiator and ½” NPT thread for connection to the system (also includes compression nut and ferrule for connection to ½” copper
Valves are available in 3 basic patterns: angle, straight, and inv
erted angle (TRV only)
Basic Installation: use 2 – LKD16AN (angle)
or LKD16SN (straight)
manual valves, nickel plated with screwdriver stops and caps
Basic upgrade: use 1 FF16WAC and 1 – FF16LAC manual valves, angle only, chrome plated with white handles (FF16WAC is adjustable for balancing, FF16LAC is fixed open but can be closed for service)
TRV (thermostatic radiator valves) are available for
automatic temperature control of individual radiators: available in 3 body patterns, with or without thermostatic head (sensor), use in conjunction with LKD or FF
TRV remote sensors and adjusters
available for special applications
DCK12 – 4” chrome nipple with
compression connection available for use with all Myson valves,
includes escutcheon (connects valve to heating system)
DAV12
– same as
DCK12
with addition of integral ball stop angle valve
Deco
rative pipe covers and escutcheo
ns
available in chrome or white (use
to cover exposed copper pipe used in radiator installation)
LKD16AN LKD16SN FF16WAC FF16LAC TRVanglew/HEAD
RemoteSensorRemoteAdjuster TRVstraight TRVinvertedangle TRVHEADonly
DCK DAV
Page 13
COLUM
N C
onversion Fact
ors / Start-up & Maintenance
Heat output factors / Start - up and Maintenance
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
13
Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty.
Step 1 Fill and vent the system.
Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position.
Step 3 Shut off and drain the system while the water is still hot. Step 4 Refill the system. Step 5 Reheat, vent, and balance the system. Step 6 Once the Décor Radiator is filled with water the system should be left filled. Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally.
SYSTEM START-UP
MAINTENANCE &
CLEANING
1
Once
operating,
avoid
the introduction of fresh water and oxygen to the system to prevent corrosion.
2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your
Myson Décor Panel Radiator.
3 The use of abrasive cleaners will damage the surface of your radiator and void the
manufacturer’s warranty.
Heat Output
The heat outputs for all MYSON COLUMN radiators can be found on pages 9 and
10. The tabulated figures are quoted in accordance with EN 442 for a mean water to air temperature of 1120F. This is based on an average water temperature of 1800F and an ambient air temperature of 680F. When the difference is not 1120F, the output should be multiplied by the appropriate factor from within the table below:
Aver. Water Temp.
0
F
Ambient Air Temp.
0
F
190 68
180 68
170 68
160 68
150
68
140 68
120 68
Water to Air
(D
elta T 0F)
Conversion Factor
122
1.14
112 1.00
102
.91
92 .79
82
.68
72
.58
52
.38
Page 14
NOTES
Notes
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
14
Page 15
NOTES
Notes
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
15
Page 16
heatingthroughinnovation.
MYSON
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
COLUMN 3/2014