2.0 Installation
l Before proceeding with the installation, the heating system
design must be considered and the unit correctly sized to
meet the heat loss requirements of the room.
l Before proceeding with the installation, unpack the carton
contents and check against the checklist below:
1. KICKSPACE
®
unit.
2. Flexible hoses including isolating valves (1 pair).
3. Instruction manual.
4. Warranty card.
5. Grille.
6. Screw fixing kit (with grille).
7. Transformer (12V model only).
8. Connector (12V model only).
l This MYSON KICKSPACE
®
fan convector is designed for
installation in the cavity beneath kitchen cupboards on the
vacant floor space, or other similar locations.
l For KICKSPACE
®
500, 600, 600-12V & 800 a minimum of
25mm clear headroom is required above the top of the
KICKSPACE
®
when fitted.
l The unit should be mounted on a clean and level floor area
under the cupboard base.
l KICKSPACE
®
80S & 80D models can only be installed if there
is a minimum height of 80mm from the top of the floor
covering to the underside of the kitchen unit (see Fig. 1).
l KICKSPACE
®
500, 600, 600-12V & 500 floor mounting (see
Fig. 2a) - The KICKSPACE
®
is normally fitted directly onto the
floor and the base of the unit is fitted with four mounting feet.
l KICKSPACE
®
500, 600, 600-12V & 500 plinth mounting
(see Fig. 2b) -
• As an alternative to floor mounting the unit may be fitted
into the plinth.
• A suitable support must be securely fitted to the floor.
• The top of the support must be level with the lower edge of
the cut-out when fitted.
l KICKSPACE
®
80S & 80D floor mountings (see fig. 2c) - Applies
to 80S & 80D units in 80mm plinth height kitchen unit.
l Decide the position of the KICKSPACE
®
, mark out and cut the
plinth to the dimensions using table on page 6.
l Position the KICKSPACE
®
under the cupboard in the required
location, with the front edge just behind the line of the plinth.
l Replace the plinth and bring the KICKSPACE
®
forward into
the opening so the front edge projects approximately 10mm
through the plinth.
l Align the grille and secure it to the unit with two screws
supplied (use the shorter screws). (See Fig. 3).
l Secure the unit/grille to the plinth with two screws supplied
(use the longer screws). (See Fig. 3).
l Complete the electrical installation, switch on and test the
KICKSPACE
®
(see Fig. 3).
l When installed in a kitchen consideration should be given to
storage of perishable goods in the cupboard above.
3.0 Water Connection
l The KICKSPACE®should only be used on closed circulation,
two pipe, pump assisted central heating systems.
l For optimum fan convector heating performance the system
must be capable of providing sufficient hot water through the
heat exchanger. This means that:
1. The minimum pipe size from boiler to fan convector must
be at least 15mm. Microbore pipe MUST NOT be used.
2. Where the unit is fitted on to a system with other emitters
a separate circuit for the fan convector should be
considered to provide adequate water flow.
3. The system water temperature on the return of the
KICKSPACE
®
must be above 43°C for the fan to switch on.
4. This unit is NOT suitable for one-pipe systems.
5. Optimum performance will require effective balancing of
the whole system.
6. This unit must not be used to replace a radiator in an
existing system unless an adequate flow of water can be
guaranteed.
l Connect valve ends of the flexible pipes to the KICKSPACE
®
.
Note: The direction of the arrows on the valves are not
significant in this application (see Fig. 4).
l Open valves fully, check pipe connections for leaks and vent
the heat exchanger. A vent screw is provided to vent the heat
exchanger.
Pipework must be positioned correctly to ensure
flexible hoses are not kinked when installed
(see Figs. 5a & 5b). Only use the hose sets
supplied with this unit. Do not use old or
alternative hose sets.
1.0
2.0
3.0
KICKSPACE
®
500, 600, 600-12V, 800, 80S & 80D
INSTALLATION & OPERATING MANUAL
01.01.2018