iVECTOR Specifiers Guide.
heatingthroughinnovation.
iVECTOR Heater/Cooler
Models: iV080, iV100, iV120, iV140, iV160
01.03.2012

1.0 Introduction 04
2.0 iVECTOR Benefits 05
2.1 Compact in Size 05
2.2 Renewable Technology 05
2.3 Rapid Response 05
2.4 Low Surface Temperature (LST) 05
3.0 iVECTOR Specification Data 06
3.1 Unit Sizes 06
3.2 Outputs 06
3.3 Flow Rates/Pressure Losses 07
3.4 Noise Levels 07
3.5 Hydronic Connections 07
3.6 Weight, Water Content and Motor Power 07
4.0 iVECTOR Installation 08
4.1 Ease of Installation 08
4.2 Mounting Dimensions 08
4.3 Water Connection - Pipe Routing Options 09
4.4 Electrical Connection 09
5.0 Applications 11
5.1 All Round Suitability 11
5.2 Traditional Heating System 11
5.3 Renewable Heating System 11
5.4 Mix ‘n‘ Match Heating Solutions 11
6.0 Intelligent and Easy to Use Controls 12
6.1 Introduction 12
6.2 Easy Mode 13
6.3 Full Mode 14
6.4 Building Management System (BMS) 15
03
Contents
Contents

04
Introduction
1.0 Introduction
The iVECTOR is MYSON’s latest product innovation and an
exciting, energy efficient addition to our range of modern
heating solutions.
The iVECTOR is the first in a new generation of intelligent fan
convectors. It has been designed specifically to combine all the
traditional advantages of a fan convector with a range of new
product benefits made possible by the inclusion of our latest
heating technology, such as a large surface area heat exchanger,
low water content, energy efficient fans and intelligent controls.
Grill Heat exchanger
Outer casing
Grill hinge
Control panel
Motor
Filter
Fan
Internal chassis

05
iVECTOR Benefits
2.1 Compact in Size
The large surface area of the iVECTOR’s heat exchanger means
that units are compact in size (all units are a standard height of
only 600mm, the same as the most popular size of panel
radiator) and occupy significantly less wall space than a panel
radiator of equivalent output. By utilising fan convection, the
iVECTOR increases its heat output even further and provides an
even distribution of warm air throughout a room. This means that
rooms feel more comfortable, even at lower temperatures.
2.2 Renewable Technology
Due to its heat exchanger and fan, the iVECTOR will produce
significantly higher heat output than a panel radiator of the same
size. This means that iVECTORs are ideal for use with low water
temperature systems. For example, when operating with a low
flow temperature of 45°C the iVECTOR will produce around
twice as much heat output as a similar double panel radiator.
2.3 Rapid Response
The iVECTOR has a low water content, between 5 and 10% of
the amount used in a traditional radiator with equivalent output.
This lower water content means that an iVECTOR produces an
instant heat response where needed and cools quicker when
heat is no longer required. Heat is accurately controlled as a
result, leading to improved indoor comfort.
2.4 Low Surface Temperature (LST)
When operating with low flow temperatures of 35 - 55°C no
outer part of an iVECTOR will exceed a temperature of 43°C. As
a result, when used with heat pumps, iVECTORs provide a high
output and energy efficient alternative to standard LST radiators
for sensitive environments such as nurseries and care homes.
(Please note that this does not apply when iVECTORs are used
with high water temperature systems, please contact MYSON
Technical Services for full information).
2.0