Myson TS4, V10, H11 2, H11 3, H11 4 Installation Manual

...
Décor Radiator Series
Installation Guide
Revised 2/12
MYSON
Décor Radiator Series
MYSON
Table of Contents
Information Symbols ................................................................................3
Rough-In ................................................................................................... 5
Connection Arrangements ......................................................................6
Mounting Details .....................................................................................7
TS4 Connection Options .........................................................................8
V10 Connection Options .........................................................................9
H11 2,3,4 Tube Connection Options .................................................... 10
H11 6,8,10 Tube Connection Options .................................................. 11
Conventional Wall Installation-Radiator ................................................12
Conventional Wall Installation-Baseboard ............................................13
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, improper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS — SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
What is covered:
• Painted finishes will not peel or flake from the surface of the radiator.
• The body of the radiator and its welded joints will not leak when the product is properly installed and maintained according to Myson’s instructions.
What is not covered:
• Rust occurring from improperly sealed threaded connections or oxygen corrosion.
• Electrolytic corrosion caused by failure to flush the system properly after initial installation.
2
Décor Radiator Series
Information Symbols
NOTE: You will see these symbols within the text of this manual, drawing your attention to important information.
Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
Information following this symbol indicates that it is important for the correct installation or use of the product. Failure to heed this information may affect the performance or useful life of the product. Risk of property damage or personal injury is low.
MYSON
Information following this symbol must be followed without exception. Failure to follow these directions could result in moderate property damage or the possibility of personal injury.
Information following this sign must be carefully followed without exception. Failure to do so could result in significant and extensive property damage or serious personal injury or death.
3
Décor Radiator Series
MYSON
Before You Begin
INSPECT FOR DAMAGE NOTE: Inspect materials for concealed shipping damage. You only have 11 days to file a freight claim. If items are damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESS Unpack the Décor Radiator carefully to avoid damage or loss of parts.
The Décor Radiator should come with the following parts:
• Wall brackets
• Plastic inserts for noise suppression
• Stainless steel solid plug
• Vent plug
INTRODUCTION
The Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the Décor Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness and dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTION Step 1 Read this entire instruction manual thoroughly before beginning installation. Step 2 To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all
the instructions carefully observing the caution notes for each step.
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATION
Myson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recommended for gravity systems. Myson Décor Radiators are designed to work with a maximum working pressure of 66 PSI and no more then 230 degrees F water temperature.
DO NOT USE STEAM IN THESE RADIATORS.
DESIGN AND LAYOUT CONDITIONS
Myson Décor Radiators should only be used with a recirculation pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Décor radiator is below a window where it can minimize downdrafts from glazed areas. Myson Radiators may be hot to the touch. Generally the surface temperature is at 10-12 degrees Fahrenheit below system water temperature. Care must be taken to consider room occupant’s ability to sense or understand that radiators may be hot. Should radiator surface or system water temperature be an issue, please contact MYSON at 1-800-698-9690 for information on the MYSON LST radiators. LST (Low Surface Temperature) Radiators can be a viable solution where temperatures are a safety concern.
4
Décor Radiator Series
Rough-in
Rough-ins given are for MYSON TRV and Control Valves only. Valve specifications vary by manufacturer. Myson will not be responsible for damage or repair of property for rough-in with non-Myson Valves. Prior to committing pipe work behind finish floor or wall materials, consult Myson for assistance at 1-800-698-9690.
Dimensions are in inches. All valves are by MYSON and are 1/2” thread engagement in a vertical pattern. For two LKD valves, use LKD and TRV dimensions.
1 Panel 1 Convector fin 2 Panel 2 Convector fin Vertical Decor
3/8"
2-1/16"
1-5/16"
2-1/16"
1-5/16"
4-1/8"
15/16"
MYSON
2-1/16"
2-3/8"
1-1/16"
3-3/16"
1-15/16"
3-3/16"
2, 3 & 4 Tier 6, 8 & 10 Tier
For the 2, 3 & 4 Tier Radiators only, there is not sufficient room with the standard mounting plates to pipe through the wall and make the angle into the radiator. You must order the optional 1-1/8” Offset Mounting Plate that appears on page 7 (Mounting Details) to accomplish this.
D
B
4-5/16"
3-3/16"
C
MODEL Product Fa ce Overall Rough-in LKD & FF LKD & TRV
H11
2,3,4 TUBES
H11 & H22 NO
6,8,10,TUBES BOTTOM
H28 NO
2,4 TUBES BOTTOM
Code Le ngth Length a t Bottom Valves Valves
H11060 23- 5/8" 24-1/4" 21-1/2" 27-7/8" 27-3/4" H11090 35 7/16" 36 1/16" 33 5/16" 39 11/16" 39 9/16" H11120 47 1/4" 47 11/16" 45 1/8" 51 1/2" 51 3/8" H11150 59 1/16" 59 11/16" 56 15/16" 63 5/16" 63 1/16" H11180 70 7/8" 71 1/16" 68 5/8" 75 1/8" 75" H11210 82 5/8" 83 1/4" 80 1/2" 86 7/8" 86 3/4" H11240 94 1/2" 95 1/8" 92 3/8" 98 3/4" 98 5/8"
H-060 23 5/8" 24 1/4" 27 7/8" 27 3/4" H-080 31 1/2" 32 1/8" 35 3/4" 35 5/8" H-100 39 3/8" 39 13/16" 43 5/8" 43 1/2" H-140 55 1/8" 55 3/4" 59 3/8" 59 1/4" H-180 70 7/8" 71 1/2" 75 1/8" 75"
H28100 39 3/8" 43 7/8" 43 3/4" H28140 55 1/8" 59 3/8" 59 1/4" H28180 70 7/8" 75 1/8" 74" H28220 86 5/8" 90 7/8" 90-3/4"
D
1-3/4"
A
TAPPINGS
TAPPINGS
B
B
C
A
V10
TS4
6 18" 14 7/8" 8 24" 20 7/8"
10 30" 26 7/8"
8 12" 9 1/4" 11 17" 141/4" 13 20" 17 1/4" 16 25" 22 1/4" 18 28" 25 3/4" 21 33" 30 1/4"
5
Décor Radiator Series
MYSON
CONNECTIONS: Myson Décor Radiators come with four 1/2” connections located at the
top and the bottom of both sides on the radiator.
P Plug V Vent S Supply R Return
2-3-4 Tube Connection Arrangements
Tapping locations are on the bottom and side of the units.
NOTE: Plug ports not being used.
Connection Arrangements
FF or LKD
SSR
A
P
S
6-8-10 Tube Connection Arrangements
Tapping locations are on both sides of the units.
Preferred methods A and B
S P
For alternate methods E and F, derate the radiation by 5%
P
SR
EF
V
V
R
A
R
V
P
V R
P
S
V
R
R
P
R
P
R
V
B
P
S
S
B
CD
P
V S
V S
R P
NOTE: Myson Radiators have British Standard Pipe Threads.
All Myson Radiators are shipped with nylon paint plugs. All plugs must be removed and replaced by the appropriate plug, vent or valve. Failure to use Myson supplied plugs may result in significant water damage!
6
Décor Radiator Series
Mounting Details
MYSON
H11 Baseboard
Flexible Along All Fins
Extended Bracket Optional
OPTIONAL 1-1/8" OFFSET MOUNTING PLATE
Part # BBWB-O
1
-
1
/
8
o
"
f
f
s
e
t
5/8"
"
6
1
/
7
-
2
"
8
/
1
"
2
/
1
-
1
Wal l St ud
Radator fins
Wall hanging
bracket
24" to 48"
L
5-7/8"
1-7/8"
5-7/8"
"
6
1
/
7
-
2
B
2 Tubes
L B
5-7/8"
5-7/8"
3 Tubes
"
8
/
1
"
2
/
1
-
1
5-7/8"
L
B
5-7/8"
4 Tubes
5-7/8"
5-7/8"
5-7/8"
51" to 96"
L
B
2 Tubes
B
3 Tubes
B
4 Tubes
B
L
B
L
B
5-7/8"
5-7/8"
5-7/8"
B=L-11-3/4" B=L-11-3/4"
H11 Radiator
H22 Radiator
Wall Mounted
Standard mounting system for all models
H28 Pedestal
Mounting with adjustable feet
3-1/2" to 4-3/4"
2
51" to 96"
L
B
B
6,8,10 Tubes
B=L-11-3/4"
5-7/8"
5-7/8"
24" to 48"
L
B
6,8,10 Tubes
B=L-11-3/4"
5-7/8"
5-7/8"
2
Type H L=39"
3-3/4" 3-3 /4" 3- 3/4" 3-3 /4"
Type H L=55" to 87"
A
A
A=L-7-1/2"
2
7
Décor Radiator Series
MYSON
CONNECTIONS: Myson Radiators come with two 1/2” BSP connections located at the
bottom of both sides on the radiator. (01 is standard)
TS4 Connection Options
1-15/16"
Vent Plug
Mounting
Brackets
P
VV
01 02
2-3/4"
79"
P
9/16"
Optional tappings available on special orders.
V = P =
Vent (1/4 in BSP)
Blind Plug/Drain
= Water inlet = Water outlet
1-5/8"
5/8"
1-3/8"
Bottom Connections Bottom Connections
2-1/8"
c
L
2-3/8" Min.
All Myson Radiators are shipped with nylon paint plugs. All plugs must be removed and replaced by the appropriate stainless steel plug, vent or valve. Failure to use Myson supplied plugs may result in significant water damage!
8
c
L
W
1-3/8"
c
L
Décor Radiator Series
V10 Connection Options
CONNECTIONS: Myson Radiators come with two 1/2” BSP connections located at the
bottom of both sides on the radiator. (01 is standard)
MYSON
15/16"
Vent Plug
Mounting
Brackets
PVV P
01 02
Optional tappings available on special orders.
V = Vent (1/4 in BSP) P = Blind Plug/Drain
2-1/16"
79"
= Water inlet = Water outlet
2-3/4"
3/16" 3/16"
Bottom
Connections
1-3/4"
All Myson Radiators are shipped with nylon paint plugs. All plugs must be removed and replaced by the appropriate stainless steel plug, vent or valve. Failure to use Myson supplied plugs may result in significant water damage!
c
L
15/16"
2-3/8" Min.
1-9/16"
c
Bottom Connections
L
W
1-9/16"
c
L
9
MYSON
2TRV1/2ANS
Décor Radiator Series
H11 2, 3, 4 Tube Connection Options
LKD 16AN
NOTE: See Radiator Range Technical Specifications for Mounting Details of Radiators.
TRV thermostatic valve and LKD lockshield valve
FF 16 WAC
FF WAC Wheelhead angle valve & LKD lockshield valve
LKD 16AN
2 LKD lockshield valves
Copper pipe
LKD 16AN
Copper pipe
LKD 16AN
Copper pipe
TRV head with vertical angle body head
2TRV RS Remote sensor 2TRV RA Remote adjuster
TRV head with inverted angle body head
888
8
8
8
8
TRV head with straight body head
8
8
8
For best accuracy 2TRV2 head should be in a horizontal position away from heat source. Remote Sensor or Adjuster heads are available
2TRV1/2ANS
FF LAC
Copper pipe
TRV thermostatic valve & FF LAC Lockshield angle valve
2TRV1/2ANS
DCK12
DAV12
FF WAC
FF WAC Wheelhead angle & FFLAC lockshield angle valve.TRV thermostatic valve & Decorative manual angle valve
DAV12DAV12
LKD 16SN
2 LKD straight lockshield valves2 Decorative manual angle valves
(FF LAC) Valve is set full open and white knob will not turn. Angle only. (FF WAC) Valve white knob can turn to open or close the valve. Angle only. (LKD) Manual valve, has chrome cap that can be removed exposing an adjustment screw to open or close the valve. Angle or straight. (TRV) Valve is a non-electric thermostatic valve that modulates water flow in response to changes in room temperature and closes when set
temperature is achieved. NOTE: This valve will not turn on or shut off your heating system. Horizontal angle, vertical angle or straight pattern.
(DCK12) Pipe extension with compression fitting and escutcheon for use with the 2TRV1/2ANS valve. (DAV12) Manual valve, adjust flow with Allen wrench. Valve comes with chrome pipe extension with compression fitting and escutcheon.
FF LAC
Copper pipe
10
Décor Radiator Series
H11 6, 8, 10 Tube Connection Options
2TRV1/2ANS
LKD 16AN
MYSON
NOTE: See Radiator Range Technical Specifications for Mounting Details of Radiators.
TRV thermostatic valve and LKD lockshield valve
FF 16 WAC
FF WAC Wheelhead angle valve & LKD lockshield valve
LKD 16AN
2 LKD lockshield valves
Copper pipe
LKD 16AN
Copper pipe
LKD 16AN
Copper pipe
TRV head with vertical angle body head
2TRV RS Remote sensor 2TRV RA Remote adjuster
TRV head with inverted angle body head
888
8
8
8
8
TRV head with straight body head
8
8
8
For best accuracy 2TRV2 head should be in a horizontal position away from heat source. Remote Sensor or Adjuster heads are available
2TRV1/2ANS
FF LAC
Copper pipe
TRV thermostatic valve & FF LAC Lockshield angle valve
2TRV1/2ANS
DCK12
DAV12
FF WAC
FF WAC Wheelhead angle & FFLAC lockshield angle valve.TRV thermostatic valve & Decorative manual angle valve
DAV12DAV12
2 Decorative manual angle valves
(FF LAC) Valve is set full open and white knob will not turn. Angle only. (FF WAC) Manual valve, white knob can turn to open or close the valve. Angle only. (LKD) Valve has chrome cap that can be removed exposing an adjustment screw to open or close the valve. Angle or straight. (TRV) Valve is a non-electric thermostatic valve that modulates water flow in response to changes in room temperature and closes when set
temperature is achieved. NOTE: This valve will not turn on or shut off your heating system. Horizontal angle, vertical angle or straight pattern.
(DCK12) Pipe extension with compression fitting and escutcheon for use with the 2TRV1/2ANS valve. (DAV12) Manual valve, adjust flow with Allen wrench. Valve comes with chrome pipe extension with compression fitting and escutcheon.
FF LAC
Copper pipe
11
Décor Radiator Series
MYSON
Step 1 (A) Determine supply and return pipe location for your size radiator. Step 2 (B) Place the hangers in the center of the mounting bracket NOTE: The hanger needs to be in the center of the bracket to allow for variance. NOTE: Install the plastic inserts on the hangers. NOTE: (C) The radiators must be a minimum of 4” off the floor. Step 3 (D) Measure the distance from the bottom of the radiator to the hanger and add 4” for step 3. Step 4 (E) Measure the distance from the bottom of the radiator to the top hanger and add 4” for step 3. Step 5 (F) Measure the distance from the center of the supply or return pipe to the center of the hanger. NOTE: Use a level to mark the hanger locations on the wall. NOTE: Attach the hangers with suitable hardware. Adequate blocking is recommended to
support the weight of the radiators.
Conventional Wall Installation-Radiator
B
Hanger
FFF
E
D
C
Many MYSON products are in excess of 70 pounds. Care should be taken to have help to lift larger radiators into place to avoid lifting injuries.
A
Mounting Bracket
E
D
C
A
12
Décor Radiator Series
Conventional Wall Installation-Baseboard
Step 1 (A) Determine supply and return pipe location for your size radiator. Step 2 (B) Measure the distance from the floor up 4”. NOTE: The radiators must be a minimum of 4” off the floor. NOTE: (C) Measure the distance from (B) to (C) the bottom of the fins. NOTE: This is the height of the lower hangers Step 3 (D) Measure the distance from the bottom of the radiator to the bottom of the upper fins. Step 4 (E) Measure the distance from the bottom of the radiator to the top hanger and add 4”
for step 3. Step 5 (F) Measure the distance from the center of the supply or return pipe to the center of the hanger.
NOTE: Use a level to mark the hanger locations on the wall. NOTE: Attach the hangers with suitable hardware. Adequate blocking is recommended
to support the weight of the radiators.
Wall stud
Radiator fins
MYSON
Wall hanging bracket
E
D
B
C
A
E
D
B
C
A
Many MYSON products are in excess of 70 pounds. Care should be taken to have help to lift larger radiators into place to avoid lifting injuries.
13
Décor Radiator Series
Valve Installation
MYSON
Nylon shipping plugs are meant solely for keeping paint from radiator threads during the painting process. Failure to remove plastic plugs and install the stainless metal plugs can result in significant property damage if heating system is run with plastic plugs in place.
Step 1 Remove all plastic shipping plugs on the radiator. Step 2 Before proceeding clean tappings of any foreign material. Step 3 Install air vent plug. Step 4 Install blanking plugs.
NOTE: See page 6 for alternate
valve and plug locations.
Step 1
Remove all plastic shipping plugs. Replace with stainless plugs supplied
Wall stud
Step 3
Air vent plug on top or side
Step 5 Apply teflon tape or compound to the
threaded nipple on the valve.
Step 6 Thread the nipple of the valve into the radiator
Step 4
Blanking plug on bottom or side
4"
using a 7/16” or 12mm Allen wrench.
CAUTION: Do not over tighten and do not use a pipe wrench on ground joint. Step 7 Cut the copper pipe to a correct length. NOTE: The pipe must fit all the way up to the stop in the valve body (approx. 1” into
the valve body).
Step 8 Place compression nut on copper pipe. Step 9 Place compression ring on copper pipe. CAUTION: DO NOT DAMAGE THE COMPRESSION RING.
Step 10 Attach valve to valve nipple and tighten coupling. Turning valve body can damage
compression ring. CAUTION: DO NOT rotate valve body. Turn compression nut only and DO NOT OVER TIGHTEN.
Step 11 Tighten compression nut.
Step 4 & 5
LKD or FF
valve
Cut pipe
Tape or compound
Wall stud
TRV
valve
Step 6
Valve body stop
Copper pipe
If glycol is to be added to the system for freezing protection, extra care must be taken to seal connections fully with teflon or pipe dope.
14
14
Step 8
Compression ring
Step 7
Compression ring nut
4"
Décor Radiator Series
Valve Installation
Myson products are designed to be installed by professional trades people. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
NOTE: MYSON products have BSP male and female threads. BSP threads are a straight running thread NOT tapered like NPT. Myson Radiator Valves are designed with BSP threads at radiator
side and NPT or compression connections to system piping.
Step 1 Clean all threaded surfaces (both external and internal).
Step 2 Apply teflon tape or pipe dope to the male threads, leaving the first thread exposed. If using
pipe dope, also apply to the female threads of the radiator. Common practice to seal BSP threads is to use heavy duty teflon tape, such as is used to seal gas pipe fittings, or anaerobic pipe dope.
Step 3 Using accepted trade practices assemble and wrench tighten fittings until proper
alignment is obtained.
MYSON
Valve body stop
Copper pipe must extend all the way to stop. This is critical.
Compression ring
(ferrule)
Copper pipe
Compression Nut
7/16" or 12mm for 1/2" valve
Valve to Spud
Threaded Connection
NOTE:
• B.S.P. British Standard Pipe Threads
• Myson Radiator Valves are designed with BSP threads at radiator side and NPT or compression connections to system piping
15
Décor Radiator Series
MYSON
Failure to flush system of debris and flux may cause premature radiator failure, which
can result in leaks and property damage NOT covered under the Myson Warranty.
SYSTEM START-UP
Step 1 Fill and vent the system. Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the
open position.
Step 3 Shut off and drain the system while the water is still hot. Step 4 Refill the system. Step 5 Reheat, vent, and balance the system. Step 6 Once the Décor Radiator is filled with water the system should be left filled. Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally.
MAINTENANCE & CLEANING
1 Once operating, avoid the introduction of fresh water and oxygen to the system to
prevent corrosion.
2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect
the finish of your Myson Décor Panel Radiator.
3 The use of abrasive cleaners will damage the surface of your radiator and void the
manufacturer’s warranty.
System Start-Up & Maintenance
ADDITIVES
Treatment of the primary water is not usually required in a properly designed system.
Treatment may be necessary if either:
1 Local waters are known for their content of corrosive material or if high bacterial levels
are present.
2 If there is a possibility that the system may be idle during a prolonged period of freezing
temperatures, system should be either drained or protected with antifreeze. If either
corrosion inhibitors or anti-freeze is to be used, it should be added AFTER the system
has been flushed in the final stages. Use only anti-freeze suitable for potable water.
Do not put heating system into operation without checking for leaks with the system up to
full operating temperature. Leaks can appear in a heated system that were not noticeable
with a cold system or air pressure check.
MYSON
1-800-698-9690
948 Hercules Drive
Colchester, VT 05446
Fax: 802-654-7022
MysonInc.com
In accordance with our policy of continual product improvement,
we reserve the right to amend specifications without prior notification
212034-2/12
Loading...