Myson ECO M125 VTH, ECO M 100T, ECO M 100, ECO M 100V, ECO M125 V User Manual

...
M 100/125 M 100/125 T M 100/125 V M 100/125 VTH M 100/125 P M 100/125 TH
MYSON ECO M/MA
www.myson.se
UK User´s manual SE Manual NO Håndbok DK Manual FI Käyttöohje PL
DESIGNATION
MYSON ECO fans are designed for ventilation of domestic and similar premises (apartments, ofces, stores, garages, bathrooms, toilets and other rooms.
SET OF SUPPLY
The following articles are included in the supplied set: Fan: 1 pc. User’s manual Packing box Screws: 4 pcs
BASIC SPECIFICATIONS
The fans are designed for operation from AC power supply with voltage of 220–240 V and frequency of 50 Hz
Fans are designed for operation at air tempera­ture max 40°C
SAFETY REQUIREMENTS
The fan MYSON ECO complies with the require­ments according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. Level of protection from access to hazardous parts and waterproof: IP34 - M-series. IP24 - MA-series.
Connection of a fan that does not have a captive power cable must be carried out by a qualied electrician. The same applies to the replacement of a fans power cable. Children or people with limited physical or mental capabilities must not use the equipment without instructions on how to use it safely. The fan must not be used outside the stated range of operating temperatures or in places where there are aggressive mixtures of gases.
ATTENTION!
Fan operation when restirictions, being able to damage or jamm blades of operation wheel, are in owing part of case, is prohibited. Precautions must be taken to avoid the black-ow of gases into the room from the open ue of gas or other appliances.
UK
Serie M
Model Description
M 100/125 Standard M 100/125 T Timer adjustable 2–30 min M 100/125 V Pull cord switch on/off M 100/125 VTH Pull cord switch, timer adjustable 2–30 min, humidity sensor 50–90 % RH M 100/125 TP Motion sensor, timer adjustable 2–30 min M 100/125 TH Timer adjustable 2–30 min, humidity sensor 50–90 % RH
Serie MA Fläktar med automatiskt kallrasskydd
Model Description
MA 100/125 Standard MA 100/125 T Timer adjustable 2–30 min MA 100/125 V Pull cord switch on/off MA 100/125 VTH Pull cord switch, timer adjustable 2–30 min, humidity sensor 50–90 % RH MA 100/125 TH Timer adjustable 2–30 min, humidity sensor 50–90 % RH MA 100/125 VT Pull cord switch, timer adjustable 2–30 min
M 100
M 125
MA 100
MA 125
UK
PREPARATION TO DEVICE OPERATION.
Attention! All maintenance works and connection of fans are to be performed only after switching off mains. Connection of fans to electric power supply must be performed only through switch with actuation length not less than 3 mm at all poles. Direction of air-charging is to comply with directionof arrow on the fan case.
If necessary, ensure conditions to prevent free access to impeller and current-carrying parts of fan by protective means from side of outcome (ventilation grille, protective cowl and so on). Con­nection of fans to electric power supply is shown in Fig. 1–6.
OPERATIONS OF CONNECTION TO POWER SUPPLY
Remove protective grid and cover. Pass power supply cords through a hole 3 (having cut a thin plastic pierce on the spot of opening beforehand). Smooth out wire rags at length 7-8 mm to clamp terminals 4 agaist stop to the metal part of the clamp and tighten them with screws. Fix cords with the help of clip 2. Reinstall cover and protective grid back.
For fans without switch, it is advisable to install powersupply switch on xed power supply wiring. Diagram of connection of fan to xed power supply wiring is shown in Fig. 7–10.
UK
1. M-serie, fan with removed cover. Model: M
1 - housing 2 - clip of power supply cords 3 - holes for power supply cords 4 - clamp terminal 5 - holes for fan mounting
2. M-serie, fans with removed cover. Models: T, TH, V, VTH
1 - housing 2 - clip of power supply cords 3 - holes for power supply cords 4 - clamp terminal 5 - holes for fan mounting 6 - timer\timer with humidity sensor 7 - pull cord switch
3. M-serie, fan with removed cover. Model: TP
1 - housing 2 - clip of power supply cords 3 - holes for power supply cords 4 - clamp terminal 5 - holes for fan mounting 6 - timer with motion sensor 7 - potentiometer T
1
2
3
ATTENTION
for fans with motion
sensors. The front cover
of the fan must be unco-
vered only from the side
of the motion sensor !
UK
4. MA-serie, fans with removed cover. Models: T, TH
1 - housing 2 - clip of power supply cords 3 - holes for power supply cords 4 - clamp terminal 5 - holes for fan mounting 6 - potentiometer T 7 - potentiometer H
5. MA-serie, fans with removed cover. Models: V, VT, VTH
1 - housing 2 - clip of power supply cords 3 - holes for power supply cords 4 - clamp terminal 5 - holes for fan mounting 6 - pull cord switch 7 - potentiometer T 8 - potentiometer H
6. MA-serie, fan with removed cover. Model: TP
1 - housing 2 - clip of power supply cords 3 - holes for power supply cord 4 - clamp terminal 5 - holes for fan mounting 6 - timer and motion sensor 7 - potentiometer T
4
5
6
ATTENTION
for fans with motion
sensors. The front cover
of the fan must be unco-
vered only from the side
of the motion sensor !
UK
Diagrams in the Fig. 7, 9 ensure operation of fans, equipped with built-in switch. Diagrams in the Fig. 8, 10 show connection of fans without built-in switch. Outer switch S is shown.
Fan switch off delay time is adjustable within the range of ap­prox. 2 to 30 minutes. Time can be regulated by potentiometer T. Delay increase direction is clockwise, and delay decrease is anticlockwise). Fans supplied with timer and humidity relay are turning on by certain humidity level. (50-90%) and are regulated by potentiometer H by rotaiton clockwise to increase and antic­lockwise to decrease level during the time, adjusted by timer.
Fans with timer and movement sensor switch on ventilator when a person moves at a distance from 1 to 4 meters with viewing angle of the sensor of 100º across and automatically switch off the ventilator in time, set by the timer from 2 to 30 minutes (by turning the T regulator clockwise for increase and counterclockwise for decrease of the delay time).
Attention!
Diagram of timer is situated under circuit potential. It is forbid­den to regulate timer’s delay time unless fan is switched off the mains. Diagram in Fig. 10 shows connection of lighting lamp to fan’s timer controlled by single switch (S is an outer switch).
When lightning lamp is off, fan works during the time, adjusted by timer.
7
8
9
10
7. M 100/125 V & TP, MA 100/125 V Power supply feed circuit for fans with built-in switch.
8. M 100/125, MA 100/125 Connection of fan without built-in switch to circuit where S is switch installed additionally.
9. M 100/125 VTH, MA 100/125 VT & VTH Fan equipped with timer / timer with humidity relay and built-in switch.
10. M 100/125 T & TH, MA 100/125 T & TH Fan equipped with timer / timer with humidity relay and wthout built-in switch.
UK
AVSEDD ANVÄNDNING
MYSON ECO-äktar är konstruerade för ventila­tion av bostadsutrymmen och liknande lokaler (lägenheter, kontor, förråd, garage, badrum, toaletter etc).
LEVERANSOMFATTNING
Följande komponenter ingår i leveransen: Fläkt: 1 st Användarhandledning Förpackning Skruvar: 4 st
TEKNISKA DATA
Fläktarna är konstruerade för drift med nätspän­ning, 220–240 V / 50 Hz
Fläktarna är konstruerade för drift vid lufttempe­ratur max 40°C
SÄKERHETSKRAV
MYSON ECO-äkten uppfyller kraven i EUs Lågspänningsdirektiv och EMC-direktiv. Berörings­skydd och skyddsgrad: IP34 - serie M IP24 - serie MA
Anslutning av äktar utan fast monterad kabel, samt byte av kabel, får endast utföras av behörig elektriker. Barn eller personer med begränsad fysisk eller mental förmåga får inte använda ap­paraten utan instruktioner om hur den används på ett säkert sätt. Drift av äkten utanför angivet drifts­temperaturområde eller i lokaler där det förekom­mer aggressiva gasblandningar är förbjuden.
OBS!
Drift av äkten i miljö där det kan komma in främ­mande objekt i luftkanalen som kan skada eller blockera äkthjulets blad är förbjuden. Undvik att installera äkten så att den kan orsaka backöde till rummet av förbränningsgaser från gasbrännare eller liknande apparater.
SE
Serie M
Beteckning Beskrivning
M 100/125 Standard M 100/125 T Timer justerbar 2–30 min M 100/125 V Dragsnöre on/off M 100/125 VTH Dragsnöre, timer justerbar 2–30 min, fuktstyrd 50–90 % RH M 100/125 TP Rörelsesensor, timer justerbar 2–30 min M 100/125 TH Timer justerbar 2–30 min, fuktstyrd 50–90 % RH
Serie MA Fläktar med automatiskt kallrasskydd
Beteckning Beskrivning
MA 100/125 Standard MA 100/125 T Timer justerbar 2–30 min MA 100/125 V Dragsnöre on/off MA 100/125 VTH Dragsnöre, timer justerbar 2–30 min, fuktstyrd 50–90 % RH MA 100/125 TH Timer justerbar 2–30 min, fuktstyrd 50–90 % RH MA 100/125 VT Dragsnöre, timer justerbar 2–30 min
M 100
M 125
MA 100
MA 125
SE
FÖRBEREDELSER FÖR DRIFT OBS!
Anslutning och underhåll får ske endast när äkten är skild från matningsnätet. Fläktar får anslutas till matningsnätet endast via en allpolig brytare med ett kontaktavstånd på minst 3 mm hos samtliga poler. Fläkten skall installeras så att strömningsriktningen överensstämmer med pilen på kapslingen.
Vid behov, hindra åtkomst till äkthjul och elek­triska komponenter från trycksidan med hjälp av äktgaller, kåpa e.dyl. Anslutning av äktar till matningsnätet illustreras av gurerna 1–6.
ANSLUTNING TILL MATNINGSNÄTET
Ta bort äktgaller och kåpa. För in matningskabeln genom hålet 3. Hålet är förstansat och täckt med tunn plast som penetreras före installation. Skala ledarändarna 7-8 mm och för in dem så långt det går i plinten 4. Dra åt plintskruvarna. Fixera kabe­länden med kabelklämman 2. Sätt tillbaka kåpa och äktgaller.
För äktar utan egen brytare är det lämpligt att göra en fast brytarinstallation. Kopplingsscheman för fast installation av äktmatning nns i gurerna 7–10.
SE
1. Fläkt i serie M med kåpan borttagen. Modell: M
1 - Kapsling 2 - Kabelklämma för matningskabel 3 - Hål för matningskabel 4 - Anslutningsplint 5 - Fästhål för äkt
2. Fläktar i serie M med kåpan borttagen. Modeller: T, TH, V, VTH
1 - Kapsling 2 - Kabelklämma för matningskabel 3 - Hål för matningskabel 4 - Anslutningsplint 5 - Fästhål för äkt 6 - Timer\Timer med fuktsensor 7 - Dragsnöre
3. Fläkt i serie M med kåpan borttagen. Model: TP
1 - Kapsling 2 - Kabelklämma för matningskabel 3 - Hål för matningskabel 4 - Anslutningsplint 5 - Fästhål för äkt 6 - Timer med rörelsesensor 7 - Potentiometer T
1
2
3
OBS
För äktar med rö-
relsesensor: äktens
frontkåpa får tas av
endast från den sida som
rörelsesensorn sitter på!
SE
4. Fläktar i serie MA med kåpan borttagen. Modeller: T, TH
1 - Kapsling 2 - Kabelklämma för matningskabel 3 - Hål för matningskabel 4 - Anslutningsplint 5 - Fästhål för äkt 6 - Potentiometer T 7 - Potentiometer H
5. Fläktar i serie MA med kåpan borttagen. Modeller: V, VT, VTH
1 - Kapsling 2 - Kabelklämma för matningskabel 3 - Hål för matningskabel 4 - Anslutningsplint 5 - Fästhål för äkt 6 - Dragsnöre 7 - Potentiometer T 8 - Potentiometer H
6. Fläktar i serie MA med kåpan borttagen. Modell: TP
1 - Kapsling 2 - Kabelklämma för matningskabel 3 - Hål för matningskabel 4 - Anslutningsplint 5 - Fästhål för äkt 6 - Timer med rörelsesensor 7 - Potentiometer T
4
5
6
OBS
För äktar med rö-
relsesensor: äktens
frontkåpa får tas av
endast från den sida som
rörelsesensorn sitter på!
SE