Myson SELECT, T6, DECOR, COLUMN, BENCH Technical Manual

01.11.2011
MYSON
heatingthroughinnovation.
Column Radiator Series
02
COLUMN.
MYSON COLUMN radiator's aesthetically sophisticated design was conceived for technologically superior heating. Their design form makes them suitable for a wide range
of architectural applications from retro to modern.
Contents/Warranty
03 04
05
06 07 08
12
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims
MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS -- SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
Painted finishes will not peel or flake from the surface of the radiator
The body of the radiator and its welded joints will not leak when the product is properly installed and maintained according to Myson's instructions.
What is not covered:
Rust occurring from improperly sealed threaded connections or oxygen corrosion
Electrolytic corrosion caused by failure to flush the system properly after initial installation
Contents
What is covered:
Important information Product description Model overview / connection dimensions
Piping & rough-in
Wall bracket position information Optional Floor bracket information
Heating outputs / weights / water content
Piping arrangements Valve selection
Heat output factors / System start - up
13
9 - 10
11
Important Information 03
BEFORE YOU BEGIN
SAFETY PRECAUTIONS
Rad
iators are hot when in use, and as such, present a
risk of burns
to
users
on
prolonged
contact.
The
temperature
of
a
radiator
is
dependent
on
the
temperature
of
the
system
water,
as
set
by
the
system installer or user. Installers and users should ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installers and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be given to installing low surface temperature radiators, or to placing guards in front of the radiators.
For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements
need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED
PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
INTRODUCTION
The Myson Column Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the Column Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness and dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTION
Step 1 Read this entire instruction manual thoroughly before beginning installation. Step 2 To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all
the instructions carefully .
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATION
Myson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom­mended for gravity systems. DO NOT USE STEAM IN THESE RADIATORS.
INSPECT FOR DAMAGE NOTE: Inspect materials for concealed shipping damage. You only have 10 days to file a freight claim. If items are
damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESS
Unpack the radiator carefully to avoid damage or loss of parts. The Column Radiator will come with the following parts:
• Wall mounting bracket kit
• Plastic inserts for noise suppression
• Stainless steel solid plug
• Vent plug
IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/ herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
DESIGN AND LAYOUT CONDITIONS
Myson Column Radiators should only be used with a properly sized recirculation pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Column radiator is below a window where it can minimize downdrafts from glazed areas.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Radiators
2 - COLUMN:
Standard Heights: 18, 24, & 79 inches (45, 60, & 200 cm)
Coatings:
1. Undercoat: electrophoretic, using water-soluble paints, conforming to
DIN 55900 part 1, stoved at 329
° F;
2. Finish: electrostatic powder coating, conforming to DIN 55900 part 2, i
n a state-of-t
he-art facility. (On request, and at a supplementary charge, a range of RAL and sanitary ware colours can be offered.) This particularly
r
obust coating is stoved at an object temperature of
356° F
.
Packaging: 1. Cardboard packaging
2. Edge protection
3. Shrink foil
COLUMN product description
Quality certificates
MYSON offers its customers strong brands that meet highest quality standards. All the production sites’ production processes are certified ac­cording to ISO. The quality and perfor­mance specifications of the convectors and heating panels have been verifi ed by recognised European institutions.
The standards that the quality certifi ­cates require us to maintain give you security, the best heating performance and premium product quality. For the MYSON warranty conditions, please refer to the table of contents page of this manual.
Strong brands of the highest quality
Connections: 4 x internal thread G 1/2“ BSP, welded-in for supply and return. Vent and drain plugs (or dummy plug) are included
Maximum positive operating pressure:
145 psi
Maximum operating temperature:
max.
72psi
max.
04
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
PRODUCT DESCRIPTION
12 - 3045
Overall Height [cm]
Number of Columns
Number of Sections
Additional sizes and models are available as special order
Tested to positive pressure:
188.5 psi
248° F
5
5
5
Manufacture
MYSON COLUMN radiators are manufactured using a unique
laser
welding proce
ss that virtually eliminates
the visible
welding
points
associated
with
the
traditional
methods
of
manufacturing
this
type
of
radiator.
The
clean
finish
significantly
enhances the
aesthetic qualities of the radiator.
Tube Details
Precision, D-
profile steel
tube is used
for
all
outside
surfaces
which
ensures
high
outputs
and
soft,
rounded
edges
for
maximum
safety.
All
MYSON
COLUMN radiators are
manufactured and tested to EN 442.
Paint Finish
Every MYSON COLUMN radiator undergoes a multi-stage pre-treatment process followed by an epoxy polyester primer coating. A stoved
epoxy
polyester powder coat in white (RAL
9016) is applied to all front and rear surfaces
allowing the MYSON COLUMN to be fitted without further painting.
MYSON COLUMN radiators carry a 5 year guarantee against defects caused by faulty materials or manufacture.
3 - COLUMN:
Standard Heights: 12, 18, & 24 inches (30, 45, & 60 cm)
4 - COLUMN:
Standard Height: 24
inches
(60 cm)
See pages 9 & 10 for standard number of sections and outputs
ABOVE EXAMPLE: 12 Sections, 3 Column, 18"High
COLUM
N model overview / connection dimensions
Dimension and Mounting Quick Reference
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
05
Length equals the number of sections times 2" Example:
56 sections times 2"
equals 112"
2"
1"
1 1/4"
1 1/4"
All tappings are 1/2" BSPT
C
L
LKD16AN
C
L
1 3/4"
1 3/4"
Shown with DAV12 and LKD16AN valves. See page 12 for additional valve choices .
DAV12
4"
3/4"
1-3/16"
2-5/16"
3-1/4"
5/8"
2"
1/2"
Position 2
Position 1
Column Radiator Wall Brackets
4 Column
5 1/2"
3 Column
4"
2 Column
2 1/2"
Pipe centers from finished wall are dependent on which mounting slot is selected on the mounting bracket and the number of columns.
2 Column 3 Column 4 Column
Position 1 Min: 21/2"
31/4"
4"
Position 2 Max:
27/8"
35/8"
43/8"
To obtain pipe centers using Myson valves multuply the number of sections by 2" and add 3.5". Example: A 12 section radiator would be 12 x 2"+ 3.5" = 27.5"
MYSON COLUMN RADIATOR ROUGH -IN SPECIFICATIONS
Loading...
+ 11 hidden pages