MYSON
Information Symbols ...............................................................................3
Before You Begin ....................................................................................4
Rough-In ..................................................................................................5
Connection Arrangements .....................................................................6
Connection Options ................................................................................7
Optional Piping Arrangements ...............................................................8
Conventional Wall Installation ................................................................9
Concrete Wall Installation ....................................................................10
Valve Installation ..............................................................................11-12
System Start-Up & Maintenance ..........................................................13
Select Radiator Series
Table of Contents
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner
for the duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a
factory defect. If replacement is required, and an exact replacement product is no longer available, Myson
reserves the right to furnish a similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation.
Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic
heating and/or basic electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication,
incorrect power line voltage, improper water source or connection, fire, flood or other Acts of God are not
covered. Freight damage claims MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS — SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
What is covered:
• Painted finishes will not peel or flake from the surface of the radiator.
• The body of the radiator and its welded joints will not leak when the product is properly installed and
maintained according to Myson’s instructions.
What is not covered:
• Rust occurring from improperly sealed threaded connections or oxygen corrosion.
• Electrolytic corrosion caused by failure to flush the system properly after initial installation.
2

Select Radiator Series
Information Symbols
NOTE: You will see these symbols within the text of this manual, drawing your
attention to important information.
Myson products are designed to be installed by professional tradespeople.
Myson instructions are meant to be thorough; however it is assumed that the
installer has the appropriate technical knowledge related to building codes,
standard trade practices, and proper use of the tools of the trade. Should a
homeowner without such knowledge or skill take it upon him/herself to attempt
the installation, Myson will not be responsible for any damages, injuries or
unsatisfactory performance of the Myson product used.
Information following this symbol indicates that it is important for the correct
installation or use of the product. Failure to heed this information may affect the
performance or useful life of the product. Risk of property damage or personal
injury is low.
MYSON
Information following this symbol must be followed without exception.
Failure to follow these directions could result in moderate property
damage or the possibility of personal injury.
Information following this sign must be carefully followed without exception.
Failure to do so could result in significant and extensive property damage or
serious personal injury or death.
3

Select Radiator Series
MYSON
Before You Begin
INSPECT FOR DAMAGE
NOTE: Inspect materials for concealed shipping damage. You only have 11 days to file a
freight claim. If items are damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESS
Unpack the Select Radiator carefully to avoid damage or loss of parts.
The Select Radiator should come with the following parts:
2 - Concrete wall brackets
1 - Stainless steel solid plug
1 - Stainless steel air vent plug
INTRODUCTION
The Myson Select Radiator will keep any room in comfort and style. We at Myson, Inc. thank you
for your purchase of the Select Radiator. Each radiator combines Myson’s compact design and
advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish.
Myson’s sleek styling and thorough testing provides attractiveness and dependability. Myson’s
goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTION
Step 1 Read this entire instruction manual thoroughly before beginning installation.
Step 2 To ensure full efficiency of your Myson Select Steel Panel Radiator, please follow all the
instructions carefully observing the caution notes for each step.
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATION
Myson radiators are only for use in recirculating closed loop hydronic heating systems. These
radiators are not recommended for gravity systems. Myson Select Radiators are designed to work
with a maximum working pressure of 78 PSI and no more then 212 degrees F water temperature.
DO NOT USE STEAM IN THESE RADIATORS.
DESIGN AND LAYOUT CONDITIONS
Myson Select Radiators should only be used with a recirculating pump closed loop hydronic
heating system. Please consult national and local codes for specific restrictions that may be
imposed on your installation. Position your radiator away from your circulator pump to avoid
either excess pressure that could force water out the air vent or excess suction that could draw
air into the system. The preferred positioning for the Select radiator is below a window where
it can minimize downdrafts from glazed areas.
Myson Radiators may be hot to the touch. Generally the surface temperature is at 10-12
degrees Fahrenheit below system water temperature. Care must be taken to consider room
occupant’s ability to sense or understand that radiators may be hot. Should radiator surface or
system water temperature be an issue, please contact MYSON at 1-800-698-9690 for information
on the MYSON LST radiators. LST (Low Surface Temperature) Radiators can be a viable solution
where temperatures are a safety concern.
4

Select Radiator Series
Rough-in
Rough-ins given are for MYSON TRV and Control Valves only. Valve specifications vary by
manufacturer. Myson will not be responsible for damage or repair of property for rough-in with
non-Myson Valves. Prior to committing pipe work behind finish floor or wall materials, consult
Myson for assistance at 1-800-698-9690.
Dimensions are in inches. All valves are by MYSON and are 1/2” thread engagement in a vertical
pattern. For two LKD valves, use LKD and TRV dimensions.
MYSON
**
* Using optional EZ-Brackets
It is not recommended to route piping through the walls for single panel radiators (TYPE 11) as
there is generally insufficient room to leave the wall and make the angle into the radiator.
Nominal
Height Size C
12” 30 9-11/16”
16” 40 13-5/8”
24” 60 21-1/2”
28” 70 25-7/16”
Actual LKD & FF LKD & TRV (2) DAV12 TRV & DAV12
Model Length Valves Valves Valves Valves
A B B B B
40G 15-3/4” 19-3/8” 19-1/8” 18-3/4” 19
50G 19-11/16” 23-5/16” 23-3/16” 22-11/16” 22-15/16”
60G 23-5/8” 27-1/4” 27-1/8” 26-3/8” 26-7/8”
70G 27-9/16” 31-3/16” 31-1/16” 30-9/16” 30-13/16”
80G 31-1/2” 35-1/8” 35-” 34-1/2” 34-3/4”
90G 35-7/16” 39-1/16” 38-15/16” 38-7/16” 38-11/16”
100G 39-3/8” 43-” 42-7/8” 42-3/8” 42-5/8”
110G 43-5/16” 46-15/16” 46-13/16” 46-5/16” 46-9/16”
120G 47-1/4” 50-7/8” 50-3/4” 50-1/4” 50-1/2”
130G 51-3/16” 54-13/16” 54-11/16” 54-3/16” 54-7/16”
140G 55-1/8” 58-3/4” 58-5/8” 58-1/8” 58-3/8”
160G 63-” 66-5/8” 66-1/2” 66-” 66-1/4”
180G 70-7/8” 74-1/2” 74-3/8” 73-7/8” 74-1/8”
”
-
5