Myson 40G, 50G, 60G, 70G, 80G Installation Manual

...
Page 1
Select Radiator Series
Installation Guide
Revised 6/12
MYSON
Page 2
MYSON
Information Symbols ...............................................................................3
Rough-In ..................................................................................................5
Connection Arrangements .....................................................................6
Connection Options ................................................................................7
Optional Piping Arrangements ...............................................................8
System Start-Up & Maintenance ..........................................................13
Select Radiator Series
Table of Contents
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, improper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS — SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
What is covered:
• Painted finishes will not peel or flake from the surface of the radiator.
• The body of the radiator and its welded joints will not leak when the product is properly installed and maintained according to Myson’s instructions.
What is not covered:
• Rust occurring from improperly sealed threaded connections or oxygen corrosion.
• Electrolytic corrosion caused by failure to flush the system properly after initial installation.
2
Page 3
Select Radiator Series
Information Symbols
NOTE: You will see these symbols within the text of this manual, drawing your attention to important information.
Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
Information following this symbol indicates that it is important for the correct installation or use of the product. Failure to heed this information may affect the performance or useful life of the product. Risk of property damage or personal injury is low.
MYSON
Information following this symbol must be followed without exception. Failure to follow these directions could result in moderate property damage or the possibility of personal injury.
Information following this sign must be carefully followed without exception. Failure to do so could result in significant and extensive property damage or serious personal injury or death.
3
Page 4
Select Radiator Series
MYSON
Before You Begin
INSPECT FOR DAMAGE NOTE: Inspect materials for concealed shipping damage. You only have 11 days to file a freight claim. If items are damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESS Unpack the Select Radiator carefully to avoid damage or loss of parts.
The Select Radiator should come with the following parts:
2 - Concrete wall brackets 1 - Stainless steel solid plug 1 - Stainless steel air vent plug
INTRODUCTION
The Myson Select Radiator will keep any room in comfort and style. We at Myson, Inc. thank you for your purchase of the Select Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness and dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTION Step 1 Read this entire instruction manual thoroughly before beginning installation. Step 2 To ensure full efficiency of your Myson Select Steel Panel Radiator, please follow all the
instructions carefully observing the caution notes for each step.
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATION
Myson radiators are only for use in recirculating closed loop hydronic heating systems. These radiators are not recommended for gravity systems. Myson Select Radiators are designed to work with a maximum working pressure of 78 PSI and no more then 212 degrees F water temperature.
DO NOT USE STEAM IN THESE RADIATORS.
DESIGN AND LAYOUT CONDITIONS
Myson Select Radiators should only be used with a recirculating pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Select radiator is below a window where it can minimize downdrafts from glazed areas. Myson Radiators may be hot to the touch. Generally the surface temperature is at 10-12 degrees Fahrenheit below system water temperature. Care must be taken to consider room occupant’s ability to sense or understand that radiators may be hot. Should radiator surface or system water temperature be an issue, please contact MYSON at 1-800-698-9690 for information on the MYSON LST radiators. LST (Low Surface Temperature) Radiators can be a viable solution where temperatures are a safety concern.
4
Page 5
Select Radiator Series
Rough-in
Rough-ins given are for MYSON TRV and Control Valves only. Valve specifications vary by manufacturer. Myson will not be responsible for damage or repair of property for rough-in with non-Myson Valves. Prior to committing pipe work behind finish floor or wall materials, consult Myson for assistance at 1-800-698-9690.
Dimensions are in inches. All valves are by MYSON and are 1/2” thread engagement in a vertical pattern. For two LKD valves, use LKD and TRV dimensions.
MYSON
**
* Using optional EZ-Brackets
It is not recommended to route piping through the walls for single panel radiators (TYPE 11) as there is generally insufficient room to leave the wall and make the angle into the radiator.
Nominal Height Size C
12” 30 9-11/16” 16” 40 13-5/8” 24” 60 21-1/2” 28” 70 25-7/16”
Actual LKD & FF LKD & TRV (2) DAV12 TRV & DAV12 Model Length Valves Valves Valves Valves A B B B B
40G 15-3/4” 19-3/8” 19-1/8” 18-3/4” 19 50G 19-11/16” 23-5/16” 23-3/16” 22-11/16” 22-15/16” 60G 23-5/8” 27-1/4” 27-1/8” 26-3/8” 26-7/8” 70G 27-9/16” 31-3/16” 31-1/16” 30-9/16” 30-13/16” 80G 31-1/2” 35-1/8” 35-” 34-1/2” 34-3/4” 90G 35-7/16” 39-1/16” 38-15/16” 38-7/16” 38-11/16” 100G 39-3/8” 43-” 42-7/8” 42-3/8” 42-5/8” 110G 43-5/16” 46-15/16” 46-13/16” 46-5/16” 46-9/16” 120G 47-1/4” 50-7/8” 50-3/4” 50-1/4” 50-1/2” 130G 51-3/16” 54-13/16” 54-11/16” 54-3/16” 54-7/16” 140G 55-1/8” 58-3/4” 58-5/8” 58-1/8” 58-3/8” 160G 63-” 66-5/8” 66-1/2” 66-” 66-1/4” 180G 70-7/8” 74-1/2” 74-3/8” 73-7/8” 74-1/8”
-
5
Page 6
Select Radiator Series
MYSON
CONNECTIONS: Myson Radiators come with two 1/2” BSP connections located at the
bottom of both sides on the radiator.
P Plug V Vent S Supply R Return
Preferred methods A, B, C, and D
Connection Arrangements
SV
VSR VV
AB C D
P
For alternate methods E, F, G, and H, derate the radiation by 5%
P
R
R
V
V
EFGH
SR
R
R
P
PS
SVVS
P
RPPR
S
S
P
All Myson Radiators are shipped with nylon paint plugs. All plugs must be removed and replaced by the appropriate plug, vent or valve. Failure to use Myson supplied plugs may result in significant water damage!
6
Page 7
Select Radiator Series
Connection Options
2TRV1/2ANS
MYSON
LKD 16AN
NOTE: See Radiator Range Technical Specifications for Mounting Details of Radiators.
TRV thermostatic valve and LKD lockshield valve
FF 16 WAC
FF WAC Wheelhead angle valve & LKD lockshield valve
LKD 16AN
2 LKD lockshield valves
Copper pipe
LKD 16AN
Copper pipe
LKD 16AN
Copper pipe
TRV head with vertical angle body head
2TRV RS Remote sensor 2TRV RA Remote adjuster
TRV head with inverted angle body head
888
8
8
8
8
TRV head with straight body head
8
8
8
For best accuracy 2TRV2 head should be in a horizontal position away from heat source. Remote Sensor or Adjuster heads are available
2TRV1/2ANS
FF LAC
Copper pipe
TRV thermostatic valve & FF LAC Lockshield angle valve
2TRV1/2ANS
DCK12
DAV12
FF WAC
FF LAC
Copper pipe
FF WAC Wheelhead angle & FFLAC lockshield angle valve.TRV thermostatic valve & Decorative manual angle valve
DAV12DAV12
2 Decorative manual angle valves
(FF LAC) Valve is set full open and white knob will not turn. Angle only. (FF WAC) Valve white knob can turn to open or close the valve. Angle only. (LKD) Manual valve, has chrome cap that can be removed exposing an adjustment screw to open or close the valve. Angle or straight. (TRV) Valve is a non-electric thermostatic valve that modulates water flow in response to changes in room temperature and closes when set
temperature is achieved. NOTE: This valve will not turn on or shut off your heating system. Horizontal angle, vertical angle or straight pattern.
(DCK12) Pipe extension with compression fitting and escutcheon for use with the 2TRV1/2ANS valve. (DAV12) Manual valve, adjust flow with Allen wrench. Valve comes with chrome pipe extension with compression fitting and escutcheon.
7
Page 8
Select Radiator Series
MYSON
The following drawings are general examples.
Consult a certified heating professional for your specific application.
Optional Piping Arrangements
General information on the use of Monoflo tees:
• Scoop type is placed on the supply
• Venturi type on the return
• If heating unit is below main or more than 4 feet horizontally from the main, use two monoflo tees facing each other
8
Page 9
Select Radiator Series
Conventional Wall Installation Using Optional EZ-Brackets
Step 1 Locate studs in wall where the radiator is to be mounted. Step 2 Mount the brackets so the radiator is a minimum of 4 inches off the floor.
• Failure to allow 4” minimum clearance below radiator can significantly reduce radiator performance.
• Attach brackets firmly to the studs using appropriate hardware making sure the spring loaded connection on brackets is on top.
• All Select Radiators use 2 brackets except the 180G which uses 3 brackets.
• Use a level to assure bracket is plumb.
Step 3 To install the radiator on the brackets, set the top edge of the top grill into the upper
part of the bracket then gently lift and snap the bottom into the lower part of the bracket.
Step 4 Position radiator to line up with the supply and return pipes.
Many MYSON products are in excess of 70 pounds. Care should be taken to have help to lift larger radiators into place to avoid lifting injuries.
9
Page 10
Select Radiator Series
MYSON
Step 1 Position radiator to line up with the supply and return pipes. Step 2 Position brackets on wall so that they line up with the centerline of the brackets on
the rear of the Select Radiator.
Step 3 Mount the brackets so the radiator is a minimum of 4 inches off the floor.
• Failure to maintain 4” minimum clearance to floor can significantly reduce radiator’s performance.
• Attach brackets firmly to the wall using appropriate hardware.
• Use a level to assure bracket is plumb.
Step 4 Lift and seat the radiator onto the brackets.
Concrete Wall Installation
Many MYSON Radiators are in excess of 70 pounds. Care should be taken to have help to lift larger radiators into place to avoid lifting injuries.
Select Mounting Bracket Locations
10
Nominal Height A B C
12” 11-13/16” 6-1/4” 6-1/4” 16” 15-3/4” 8-3/16” 6-1/4” 24” 23-5/8” 9 28” 27-9/16 10-15/16” 12-3/8”
” 12-3/8”
-
Page 11
Select Radiator Series
Valve Installation
Nylon shipping plugs are meant solely for keeping paint from radiator threads during the painting process. Failure to remove plastic plugs and insert the stainless metal plugs can result in significant property damage if heating system is run with plastic plugs in place.
Step 1 Remove all plastic shipping plugs on the radiator. Step 2 Before proceeding clean tappings of any foreign material. Step 3 Install air vent plug. Step 4 Install blanking plugs.
NOTE: See page (5) for alternate
valve and plug locations.
Step 5 Apply teflon tape or compound to the
threaded nipple on the valve.
Step 6 Thread the nipple of the valve into the radiator
using a 7/16” or 12mm Allen wrench.
CAUTION: Do not over tighten and do not use a pipe wrench on ground joint. Step 7 Cut the copper pipe to a correct length. NOTE: The pipe must fit all the way up to the stop in the valve body (approx. 1” into the valve body). Step 8 Place compression nut on copper pipe. Step 9 Place compression ring on copper pipe. CAUTION: DO NOT DAMAGE THE COMPRESSION RING. Step 10 Attach valve to valve nipple and tighten coupling. Turning valve body can damage compression
ring.
CAUTION: DO NOT rotate valve body. Turn compression nut only and DO NOT OVER TIGHTEN. Step 11 Tighten compression nut.
MYSON
If glycol is to be added to the system for freezing protection, extra care must be taken to seal connections fully with teflon or pipe dope.
11
11
Page 12
Select Radiator Series
Valve Installation
Myson products are designed to be installed by professional trades people. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
NOTE: MYSON products have BSP male and female threads. BSP threads are a straight running thread NOT tapered like NPT. Myson Radiator Valves are designed with BSP threads at radiator
side and NPT or compression connections to system piping.
Step 1 Clean all threaded surfaces (both external and internal).
Step 2 Apply teflon tape or pipe dope to the male threads, leaving the first thread exposed. If using
Step 3 Using accepted trade practices assemble and wrench tighten fittings until proper
MYSON
pipe dope, also apply to the female threads of the radiator. Common practice to seal BSP threads is to use heavy duty teflon tape, such as is used to seal gas pipe fittings, or anaerobic pipe dope.
alignment is obtained.
Valve body stop
Copper pipe must extend all the way to stop. This is critical.
Compression ring
(ferrule)
Copper pipe
Compression Nut
7/16" or 12mm for 1/2" valve
Valve to Spud
Threaded Connection
NOTE:
• B.S.P. British Standard Pipe Threads
• Myson Radiator Valves are designed with BSP threads at radiator side and NPT or compression connections to system piping
12
12
Page 13
Select Radiator Series
System Start-Up & Maintenance
Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty.
SYSTEM START-UP
Step 1 Fill and vent the system.
Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the
open position.
Step 3 Shut off and drain the system while the water is still hot.
Step 4 Refill the system.
Step 5 Reheat, vent, and balance the system.
Step 6 Once the Select Radiator is filled with water the system should be left filled.
Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally.
MYSON
MAINTENANCE & CLEANING 1 Once operating, avoid the introduction of fresh water and oxygen to the system to
prevent corrosion.
2 An occasional wiping with a damp cloth using a non abrasive detergent can protect the finish of your Myson Select Panel Radiator.
3 The use of abrasive cleaners will damage the surface of your radiator, and void the manufacturer’s warranty.
ADDITIVES
Treatment of the primary water is not usually required in a properly designed system. Treatment may be necessary if either: 1 Local waters are known for their content of corrosive material or if high bacterial levels are present.
2 If there is a possibility that the system may be idle during a prolonged period of freezing temperatures, system should be either drained or protected with antifreeze. If either corrosion inhibitors or anti-freeze is to be used, it should be added AFTER the system has been flushed in the final stages. Use only anti-freeze suitable for potable water.
Do not put heating system into operation without checking for leaks with the system up to full operating temperature. Leaks can appear in a heated system that were not noticeable with a cold system or air pressure check.
13
Page 14
Select Radiator Series
Notes
MYSON
14
Page 15
Select Radiator Series
Notes
MYSON
15
Page 16
MYSON
Select Radiator Series
Installation Guide
MYSON
1-800-698-9690
948 Hercules Drive
Colchester, VT 05446
Fax: 802-654-7022
www.MysonInc.com
In accordance with our policy of continual product improvement,
we reserve the right to amend specifi cations without prior notifi cation
212033-6/12