CONTENTS
No sound:
Power turned off or system in standby mode. Check that the LED in the STANDBY button is blue.
The input connection is loose or missing. Check that the connection is secure.
Protection relay has operated because of a short circuit loudspeaker wire or amplifier overheating. Carefully check all wiring after switching the amplifier POWER OFF to allow it to cool.
The fuse in the power cord inlet has failed. Unplug the power cord from both the wall socket and the amplifier and pull out the small receptacle below the power cord inlet. Two fuses should be visible. The further fuse is the operative one and should be checked. If it has failed, replace it with the nearer (spare) fuse. If this too fails, then return the amplifier to your dealer for service.
UK version only: The fuse in the mains plug has failed. Check and replace if necessary.
Sound in one channel only:
Loudspeaker cable pulled loose. Check all connections, both at the loudspeakers and amplifier.
Interconnect cable pulled loose or making poor contact. Check and, if necessary, un-plug and re-plug all relevant cables.
Amplifier produces less power than normal. First level temperature protection activated (see page 6). Reduce volume, or improve ventilation to allow amplifer to cool.
Amplifier fails to respond to My Link remote commands (from e.g. MDP
500
Preamplifier-Processor):
My-Link cable is loose or not connected. Check connections on all linked units.
Loud buzz or hum:
Interconnect cable pulled partially out of its socket.
Defective interconnect cable.
Incorrect operation - some functions not working:
Control processor latched. Switch off POWER on rear panel and wait for about one minute. Then switch POWER on. Normal operation should resume.
TROUBLE-SHOOTING GUIDE
SPECIFICATIONS
Some of the most common problems
Five channels driven
Continuous average power output(<0.05% THD, 20Hz-20kHz) …………………………………………………8:100W
…………………………………………………………………………………………………………………………4:150W
IHF dynamic power……………………………………………………………………………………………………8:150W
…………………………………………………………………………………………………………………………4:240W
One channel driven
Maximum continuous power output (1% THD, 1kHz) ……………………………………………………………8:160W
…………………………………………………………………………………………………………………………4:280W
IHF dynamic power……………………………………………………………………………………………………8:180W
…………………………………………………………………………………………………………………………4:320W
Input sensitivity (for 100W into 8Ω)………………………………………………………………………………………1.0V Voltage Gain…………………………………………………………………………………………………………………29dB Input impedance …………………………………………………………………………………………………25 k/440pF Frequency response (20Hz - 20kHz)……………………………………………………………………………………±0.2dB Signal/Noise ratio (A weighted, ref. 100W) ……………………………………………………………………………110dB Line inputs………………………………………………………………………………………………………5 x RCA phono Line outputs ……………………………………………………………………………………………………5 x RCA phono Control inputs/outputs ………………………………………………………………………My-Link I/O: 2 x RCA phono
…………………………………………………………………………………………DC trigger I/O: 2 x 3.5mm mono jack
Loudspeaker outputs ……………………………………………………………5 pairs of gold-plated 5-way binding posts
Physical specification
Dimensions (width x height x depth) …………………………………………………………………436 x 135 x 368 mm Weight, Net: ………………………………………………………………………………………………………………20 kg
Power requirements
Voltage (set by internal wiring) …………………………………………………………………………………120 or 230 V
Stock No: OST0012000