MYPV AC THOR Assembly Instructions Manual

AC•THOR® Assembly Instructions, Version 180604 1
AC•THOR
®
Assembly Instructions
The Operation Manual of the device is available at
www.my-pv.com.
The following device key is required for online registration of the unit. Keep it safe! Please see the Operating instructions for further information.
Device Key
AC•THOR® Assembly Instructions, Version 180604 2
Contents
Intended use ........................................................................................................................................... 3
Scope of supply ....................................................................................................................................... 3
Safety instructions ....................................................................................................................... 3
Limitation of warranty and liability ....................................................................................................... 4
Connections ............................................................................................................................................. 5
Assembly .................................................................................................................................................. 5
Connecting several temperature probes ............................................................................................. 7
Electrical connection ..................................................................................................................... 7
Electrical connection for multiple units ..................................................................................... 7
Wiring diagrams ...................................................................................................................................... 8
Wiring the AC•THOR control side .................................................................................................... 8
Power meter – connection via router ......................................................................................... 8
Power meter – connection without router ................................................................................. 9
Power meter – connection via Powerline without router ....................................................... 10
Control by inverter or battery management ........................................................................... 11
Control by the energy management system ........................................................................... 12
Wiring AC•THOR applications ........................................................................................................ 13
Operating mode M1: Hot water 3 kW ....................................................................................... 13
Operating mode M2: Hot water stratification charge ............................................................. 14
Operating mode M3: Hot water 6 kW ....................................................................................... 15
Operating mode M4: Hot water + domestic hot water heat pump ....................................... 16
Operating mode M5: Hot water + space heating .................................................................... 17
Connecting three-phase heating elements ................................................................................. 18
Maintenance .......................................................................................................................................... 19
Operation displays ................................................................................................................................ 19
Troubleshooting .................................................................................................................................... 20
Disposal ................................................................................................................................................. 20
EU declaration of conformity ............................................................................................................... 20
Technical specifications ........................................................................................................................ 20
AC•THOR® Assembly Instructions, Version 180604 3
Intended use
The electronic AC•THOR Photovoltaic-Power-Manager (in the following, AC•THOR for short) is designed for operating resistive loads such as electric immersion heater elements, electric boilers, electric convectors, electric heating mats or infrared panels. The unit controls the output voltage according to external signals (temperatures, Ethernet- and other control signals) linearly and thus the power output of the connected load.
The AC•THOR is controlled by the my-PV Power Meter or can be combined with products of different manufacturers (the current list of manufacturers can be seen under www.my-pv.com).
The AC•THOR is designed for fixed installations indoors.
In sanitary facilities, the relevant regulations must be observed!
Any application other than those described above may cause damage.
Furthermore, this may lead to hazards such as a short circuit, fire, electric shock, etc. The safety instructions and the information on handling in this manual and in the operation instructions shall be followed!
The product complies with the statutory, national and European requirements. The names of the company and products are trademarks of my-PV GmbH. All rights reserved.
You will find a comprehensive description of the unit's functions and potential settings
using the display or via web interface in the online Operating instructions.
Scope of supply
AC•THOR Electronic Photovoltaic Power Manager Wall bracket (on the rear of the unit) Assembly set (3 screws 4.2 x 32 mm, 3 wall-plugs 6 mm) my-PV digital temperature sensor (cable length 5 m) with 8-pin plug Plug, 3-pin for 16 A switch output (attached to the unit) Operator stylus for the display with holder Assembly Instructions Key-fob AC•THOR
Safety instructions
The AC•THOR is designed for fixed installations indoors.
The connected units may only be pure resistive electric loads such as immersion heater elements, boilers, convectors, heating mats or infrared panels! The units connected must be suitable for variable supply voltages between 0-230 V AC (in no circumstances units with electronic power supply) as this otherwise may cause damage to the AC•THOR or to the other loads connected to it.
Only connect loads fitted with suitable mains plugs to the load socket!
In cases where the load to be connected has no mains plug, a 16 A earthed EURO mains plug must be fitted (not supplied).
Operation of heating systems incorporating electronic thermostats is not possible!
For heating water, only heaters with an integral safety temperature limiter may be connected.
Installation must be carried out by an accredited specialist.
AC•THOR® Assembly Instructions, Version 180604 4
Comply with the relevant standards when mounting and connecting the device.
The unit housing may heat up during operation. Only mount the unit on non-combustible surfaces.
The unit is only intended for use in dry rooms indoors. Otherwise there is a risk of fatal electric shock!
In sanitary facilities, the relevant regulations must be observed!
Do not install the device in an environment contaminated with ammonia.
Do not install the device in a dusty environment.
The ventilation holes of the housing must not be covered.
Avoid exposure to high temperatures (> 40°C), low temperatures (< 5°C) or direct sunlight during storage and operation.
The AC•THOR must be connected to a nominal voltage of 230 V AC, 50 Hz.
Protection of the mains connection for the AC•THOR may not exceed 16 A (tripping
characteristic B or C).
The accident prevention regulations established by the German Employer's Liability Insurance Association for electrical equipment and facilities must be adhered to in commercial facilities.
This unit can be used by children ages 8 and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the safe use of the equipment and understand the resulting risks. Children should not play with the appliance. Cleaning and user maintenance shall not be undertaken by children without supervision.
Limitation of warranty and liability
A limitation of warranty and liability applies for:
any damage or injury caused by improper handling or failure to observe the assembly and
operating instructions
Consequential damage, in particular to the connected loads Altering, disassembling or otherwise intervening in the device or making changes to the
device without authorisation
AC•THOR® Assembly Instructions, Version 180604 5
Connections
Assembly
A brief video (German) to explain assembly will also be found online:
https://www.youtube.com/watch?v=WFHbayf5VDQ
Remove the wall bracket from the rear of the AC•THOR unit. To do this, slide the lock underneath to the right.
AC•THOR® Assembly Instructions, Version 180604 6
Then fix the wall bracket to the wall with three screws. Three screws and three wall-plugs are supplied. If the screws supplied are not suitable for the substrate, suitable screw must be obtained.
To fix it to the wall bracket, the AC•THOR is suspended in the wall bracket by the two long slots on top and then fixed in place by locking it underneath (slide to the left).
Check the AC•THOR is securely fixed!
Then the electrical connections can be made.
Do not immerse my-PV temperature sensor(s) directly in water. Use a thermowell!
TIP: For mains leads, use a cable duct with a depth of 60 mm. The necessary cut-out measures 130 x 60 mm.