All contents of this manual are copyrighted by Mylex
Corporation. The information contained herein is the
exclusive property of Mylex Corporation and shall not be
copied, transferred, photocopied, translated on paper, film,
electronic media, or computer-readable form; or otherwise
reproduced in any way, without the express written
permission of Mylex Corporation.
Notice
This Manual describes the Mylex FlashPoint™ LT BT-930 PCI to SCSI Host A dapter.
Although reasonable efforts have been made to as sure the accuracy of the information
contained herein, this publication could include technical inaccuracies or typographical
errors. Mylex Corporation expressly disclaims liability for any error in this information,
and for damages, whether direct, indirect, special, exemplary, consequential or otherwise,
that may result from such error, including but not limited to loss of profits resulting from
the use or misuse of the manual or information contained therein (even if Mylex
Corporation has been advised of the possibility of such damages). Any questions or
comments regarding this document or its contents should be addressed to Mylex
Corporation at the address shown on the cover.
The following paragraph does not apply to the United Kingdom or any country where such
provisions are inconsistent with local law:
MYLEX CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
Some states do not allow disclaimer of express or implied warranties or the limitation or
exclusion of liability for indi re ct, special, e xemplary, incidental or consequential damages
in certain transactions; therefore, this statement may not apply to you. Also, you may have
other rights which vary from jurisdiction to jurisdiction.
Information in this publication is subject to change without notice and does not represent a
commitment on the part of Mylex Corporation. Changes may be made periodically to the
information herei n; th ese changes will be incorporate d in new editions of the publication.
Mylex Corporation rese rv es th e ri ght to mak e i mpro v emen ts and/ or cha nges a t an y time in
the product(s) and/or program(s) described in this publication.
It is possible that this publication may contain reference to, or information about, Mylex
Corporation prod uct s (machines and pro grams), programming or services that are not
announced in your country. Such references or information must not be construed to mean
that Mylex Corporation inte nds to an no unce, provide, or make av a ilable such Mylex
products, programming, or services in your jurisdiction.
Requests for technical information about Myl ex Cor poration products should be made to
your Mylex authorized reseller or Mylex marketing representative.
Mylex is a registered trademark of Mylex Corporation. FlashPoint and MultiMaster are
trademarks of Mylex Corporation.
Microsoft and MS-D O S are registered trademarks of Microsoft Corporation. Windows,
Windows 95, and Windows NT are trademarks of Microsoft Corporation.
SCO and UnixWare are registered trademarks of The Santa Cruz Operation, Ltd.
Novell and NetWare are registered trademarks of Novell, Inc.
Unless otherwise noted, companies, names and data used in examples herein are fictitious.
Class B Compliance
THIS DEVICE COMPLIES WITH PART 15 OF THE F CC RULES . OP ERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are de signed to
provide reasonable protection against harmful interference in re sidential installation s.
This equipment generates, uses, and can r a diate radio frequen cy energy, and if not
installed and used in accordance with the instruc tions, may cause harmful interfere nce
to radio communications. However, there is not guarantee that interference will not
occur in a particular installation.
If this equipme nt doe s cau se interference to rad i o or te lev i s io n equipment recept ion ,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Move the equipment away from the receiver
3. Plug the equipment into anm outlet on a circuit different from that to which the
receiver is powered.
If necessary, the user should consult the dealer or an experienced radio/television
technician for additional sugge st ion s.
All external connections should be made using shielded cables..
m Caution
Only equipment certified to comply with Class B
(computer input/output devices, terminals, printers,
etc.) should be attached to this equipment.
Any changes or modif ications to the equip ment by the
user not expressly approved by the grantee or
manufacturer could void the user’s authority to
operate such equipment.
Declares that the product: Mylex FlashPoint
Product Name:PCI to SCSI Host Bus Adapter
Model Number(s):FlashPoint LT BT-930
Year of Manufacture:1997
Conforms to the following Product Specification(s):
EMC:EN 50081-1:1992/EN 55022:1992 Class B
EN 50082-1:1992 - Generic Immunity
EN 61000-4-2:1995,4kV CD, 8kV AD
EN 50140:1995, 3 V/m, 80 - 1000 MHz, 80%
EN 61000-4-4:1995, 0.5kV I/O, 1kV Power
Supplementary Information:
The product herewith complies with the requirements to the EMC Directive
89/336/EEC
Declaration that the equipment specified above conforms to the
above directive(s) and standard(s) is on file and available for
inspection at the manufacturer’s address cited above.
Community of Europe
CE mark is rated for the FlashPoint LT BT-930 PCI to SCSI Host Adapter as follows:
CISPR 22 Radiated Emission
EN55022, EN5082 -1 Generic immunity standard for the following:
IEC 801-2 ESD, IEC 801-3 Radiated, and IEC 801-4 EFT/Burst
Warning!
This is a Class B product. In a residential environment this product may cause radio
interference, in which case the user may be required to take adequate measures.
Achtung!
Dieses ist ein Gerät der Funkstörgren zwertklasse B. In Wohnbereichen können bei
Betrieb dieses Gerätes Rundfunkstöru ngen aufreten, in welchen Fällen der Benutzer
für entsprechende Gegenmaßnahmen verantwortlich ist.
Avertissement!
Cet appareil est un appareil de Classe B. Dans un environnement résidentiel cet
appareil peut provoquer des brouilla ges radioélectriques. Dans ce cas, il peut être
demandé à l’utilisateur de prendre des mésures appropriées.
About This Manual
This installation guide covers information necessary to install and configure
the Mylex FlashPoint LT PCI to SCSI Host Bus Adapter.
Conventions
Throughout the manual, the following conventions are used to describe user
interaction with the product:
boldThe user must enter the bold text exactly as shown
↵Press the Enter key
EnterPress the key labeled “Enter” (or “Delete”, etc.)
File, Run Select the Run option from the pull-down menu
activated when the File menu pad is selected
☛
Note
Supplementary information that can ha ve an effect on
system performance
m Caution
Notification that a proscribed action has the potential
to adversely affect equipment operation, system
performance, or data integrity
,
WARNING
Notification that a proscribed action will
result i n equipment damage, data loss, or personal
injury
Product Support Record ....................................................................B-2
viiiFlashPoint™ LT BT-930 User’s Manual
Chapter 1
Introduction
The Mylex FlashPoint™ LT PCI Host Adapter is a single channel host
adapter offering device driver support for major industry standard desktop
operating systems. It is based on Mylex-designed ASIC technology. It
provides high-performance interconnection between the Peripheral
Component Interconnect (PCI) bus and up t o seven Small C omp ut er Sys t em
Interface (SCSI) peripheral devices.
Green LED
Red LED
External SCSI
Connector (SCSI 2)
Figure 1-1. The FlashPoint LT Host Adapter
Internal SCSI
Connector
Mylex
SCSI
ASIC
BIOS
LED
Connector
The FlashPoint adapter complies with PCI Specification Rev. 2.1, operating
at the maximum PCI local bus rate of 133 MBytes/sec in 32-bit data burst
mode. Mylex host adapters offer exceptionally high product reliability due to
reduced component count and lower power consumption. Minimized
command overhead results in faster command execution. The adapter BIOS
supports disk drives, even those with greater than 8 GBytes capacity.
Manual No. 30008631-1
Configuration
Configuration
Plug and Play Operation. FlashPoint adapter configuration is handled by
the PCI motherboard. Operating parameters can be adjusted using
AutoSCSI, a menu-driven utility residing in the adapter’s Read Only
Memory (ROM).
Features
The FlashPoint PCI host adapter has the following features:
• Fast data transfer rates
The FlashPoint supports standard data transfer rates including Fast
SCSI-2 at 10 megabytes per second and Ultra SCSI rates at 20
megabytes per second.
• SCAM Support
The FlashPoint supports the SCSI-3 SCAM (SCSI Configured
Automatically) ConLevels 1 and 2 protocols for SCSI ID assignment.
SCAM devices do not require manual SCSI ID assignment. The
FlashPoint adapter assigns a SCSI ID to the de vice as requir ed. See the
owner’s manual for your peripheral devices to determine whether or
not they support SCAM.
• SmartTerm
The FlashPoint has no onboard jumpers. With SmartTerm, the
FlashPoint adapter determines the configuration of the daisy chained
devices, and self-terminates as required. See the owner’s manual for
your SCSI devices to determine how they support termination.
•SeqEngine
SeqEngine provides automated SCSI command processing which
reduces SCSI command overhead by minimizing the need to interface
with the host processor. This results in improved performance.
1-2FlashPoint™ LT BT-930 User’s Manual
Introduction
Hardware Requirements
Your PCI computer needs:
• One available PCI b us master e xpansion slot for each FlashPoint being
installed
• A 3.5" floppy drive
• DC power for internal SCSI drives or AC power for external
subsystems
You need the following cables:
• A 50-pin cable with a high-density connector to connect the
FlashPoint adapter to external devices
• A 50-pin, flat ribbon cable to connect internal SCSI devices to the
FlashPoint adapter (included with adapter kit)
• An optional cable to connect the drive activity LED on the host front
panel to the FlashPoint adapter
☛
Note
The device activity LED cable is usually supplied
with the host system.
The peripherals you are attaching to the FlashPoint adapter should be
SCSI-2 or SCSI-3 Common Command Set (CCS) compatible.
Manual No. 30008631-3
Software Requirements
Software Requirements
You may need the following software:
• Software for hard drive setup to perform partitioning and high-level
formatting
• Operating system software for hard drives being installed
• Device drivers
Device Driver Needs
You may also find the drivers that you need in the Mylex SCSI Host Adapter
Software Kit. This kit contains device drivers that support:
• Multiple FlashPoint host adapters
• Up to seven SCSI peripheral devices (hard drives, etc.) per adapter
• Connectivity to SCSI tape drives, magneto optical (MO) disk drives
and CD-ROM drives and other devices
See the FlashPoint Software User’s Guide if you are installing Mylex
drivers.
Supported Operating System/Driver Support
Mylex SCSI adapter driver support are available for the following operating
systems:
• PC/MS DOS 5.0 and above
• IBM OS/2 2.1x and Warp
•Windows 95
•Windows 3.x
• Windows NT 3.5x
• NetWare 3.1x, NetWare 4.x and 4.1x
•Solaris
• SCO UNIX
• UNIXWare
• Banyan Vines
1-4FlashPoint™ LT BT-930 User’s Manual
Introduction
PC-DOS, MS-DOS and Windows. Your host adapter’s onboard BIOS
allows you to attach up to seven SCSI disk drives without additional
software under PC or MS-DOS 5.0 and above. Earlier versions of DOS only
allow support for up to two hard disk drives.
Mylex offers device drivers that support ASPI (Advanced SCSI Program
Interface) for configurations where more hard drives are needed than your
version of DOS can support. Mylex also offer s CDROM dri ver s for DOS and
Windows.
If you are installi ng other types of d e vices un der DOS and W in do ws, s uch as
a tape backup device or a scanner, you will need to install additional drivers
that support the ASPI interface to operate those devices. Those drivers are
usually available packaged with the device or from third party sources.
☛
Note
You can obtain the latest Mylex driver updates from
the Mylex Bulletin Board System (BBS) for host
adapter products, via modem at 510-7 93-3491. (Up to
14.4K, N, 8, 1)
See the FlashPoint Software User’s Guide if you are installing Mylex
drivers.
Manual No. 30008631-5
Reference Documents
Reference Documents
You should have the following documents on hand during installation:
• The installation and set-up guide for your computer
• The installation guide for your SCSI peripherals (e.g., hard drive,
CD-ROM or tape drive)
• Operating system installation and user’s guide
• FlashPointSoftware User’s Guide or third-party device drivers (if
applicable)
Specifications
Dimensions:
Electrical:
Operating Voltage5±0.25V
Operating Current .6A Max.
Max. Ripple/Noise100 mV and 100 mV
Environmental:
Temperature0°C to 60°C (32°F to 128°F)
Relative Humidity10% to 95% non-condensing
Altitude0 to 10,000 ft. operating
This section details hardware installation. See Chapter 3 for information on
using AutoSCSI to configure adapter operati ng parameters.
What’s Covered in This Section
1. Unpacking the adapter and preparing for installation
2. Installing your FlashP oint
3. Configuring and cabling internal SCSI devices
4. Configuring and cabling external SCSI devices
5. Powering up the system
6. Hard drive set up
Unpacking
Before handling the FlashPoint, take precautions to avoid damage from
electrostatic discharge: either use a grounding strap, or, touch your a metal
part of your computer chassis to discharge static electricity before handling
the board. Always hold the board b y the edg es, even after static electricity is
discharged.
1. Check that your shipment is complet e w ith cables, documentation and
diskette.
2. Remove the board from its protective envelope.
3. Verify that no physical damage occurred during shipping by inspecting
the board for bent pins, loose parts, broken traces, and chipped or
broken connectors.
Manual No. 30008632-1
Installation Tools
Warran ty Information
If damage to the board has occurred, return it in the protective envelope and
original packaging with this manu al to your Mylex board supplier. The
shipping agent should also be notified if the unit has been damaged during
shipment. The Mylex warranty conditions are given in the back of this
manual.
Installation Tools
The following items may be needed to assist with installing the adapter into
your system:
• Small screwdriver
• Host system hardware manuals and manuals for the peripherals being
installed.
Setting the SCSI Device ID
Each SCSI device is assigned a unique SCSI ID ranging from 0 through 7.
Most SCSI peripheral devices are shipped with a preassigned SCSI ID
number. Your FlashPoint is , by default, SCSI ID 7.
If you need to change the SCSI ID for a peripheral device, refer to the
instructions in its owner’s manual. A SCSI ID jumper or switch is usually
located on the peripheral’s back panel.
T o change you r adapter SCSI ID use the V iew/Modify Adapter Configuration
option on the AutoSCSI’s Adapter Configuration Menu (Chapter 3, “Adapter
and Device Configuration”).
☛
Note
FlashPoint LT allows the user the option of selecting
the boot drive and specifying its SCSI ID through
AutoSCSI. If the SCSI ID of the boot drive is set to
zero then BIOS looks for the boot drive by scanning
devices according to their SCSI ID, starting at SCSI
ID 0. In this case, mak e sure that your bo ot device has
the lowest SCSI ID.
2-2FlashPoint™ LT BT-930 User’s Manual
Installation
SCAM Support
The FlashPoint adapter supports SCAM Levels 1 and 2. If your peripheral
device supports SCAM, the FlashPoint adapter will determine an available
SCSI ID and assign it to the device.
SCSI peripheral devices that do not support SCAM (legacy) are shipped with
a preassigned SCSI ID number . You can change this ID if necessary . A SCSI
ID switch is usually located on the back panel of such devices. It may be in
the form of a jumper or a switch whose setting indicates the SCSI ID. If you
need to change the SCSI ID for the other peripheral devices, refer to the
instructions in the owners manual for the device.
Terminating SCSI Devices
The SCSI devices connected on the ends of the cable of a SCSI bus must
have terminators installed or enabled. Terminators, which can be connected
to either SCSI devices or SCSI cables, are required for reliable operation of
the SCSI bus.
☛
Note
Pass through cable t erminat ors may not prop erl y
terminate the device. For greater reliability, Myle x
recommends the use of active terminators for all
devices.
If more than two SCSI devices are connected in a SCSI daisy chain, disable
the termination on the middle device(s).
The FlashPoint is equipped with SmartTerm™ and does not require any
physical configuration for termination. SmartTerm requires no user
interaction and automatically enables or disables the FlashPoint termination
depending on the configuration of the SCSI bus in the system.
☛
Note
There are devices on the market, such as some pass
through terminators and de v i ces with 26-pin DB
connectors, that do not conform to SCSI
specifications. With such devices on the cable, the
SmartT er m log ic on th e FlashPoint LT board does not
Manual No. 30008632-3
Installing Your FlashPoint
work properly. To overcome this problem, the
FlashPoint adapters provide an AutoSCSI option to
disable onboard termination.
Installing Your FlashPoint
Step 1: Prepare the host system and the adapter
When you are ready to begin, power down the host system.
Referring to your host system owner’s manual, remove the covers to open
the case to gain access to the motherboard and expansion slots as shown in
Figure 2-1.
If the computer has been on, wait a few minutes until the power supply case
has cooled down inside the computer. If the power supply case is cold, touch
it to discharge any static electr icity t hat may be on your clothes or body.
Figure 2-1. Remove the Cover and Bracket
To install the adapter card, remove the mounting screw and the existing
bracket from the rear panel behind the selected PCI slot.
2-4FlashPoint™ LT BT-930 User’s Manual
Installation
☛
Note
The FlashPoint adapter can only be installed in a
busmaster slot. Refer to your syst em docum en tatio n to
determine the correct slot for installation.
Step 2: Install the adapter
Press the FlashPoint adapter into the selected PCI slot (see Figure 2-2).
Align the mounting bracket, and reinstall the mounting screw.
Figure 2-2. FlashPoint adapter Installation
m Caution
Make sure that the board is properly seated in the slot.
Step 3: Install internal devices and cables
Internal devices require a 50-pin flat ribbon cable. Use the ribbon cable
included with the FlashPoint to install o ne or two internal devices. Install
one end of the ribbon cable to the 50-pin double-row SCSI connector on the
FlashPoint host adapter (see Figure 2-3).
Before plugging in the cable, check that the “▼” mark molded on the
connector or the colored stripe on the cable (indicating the location of Pin 1)
matches Pin 1 of the connector on the board.
Manual No. 30008632-5
Installing Your FlashPoint
Figure 2-3. Installing Internal Devices and Cables
When installing one internal device, connect it to the end of the cable and
terminate the device. Consult the owners manual for information on how to
terminate the device.
If a second internal device is to be included in the internal installation,
terminate only the device at the end of the cable. If the default config uration
for the device in the middle of the cable is terminated, consult the owner’s
manual to find out how to disable termination.
Be sure each device has a unique SCSI ID assigned. See “Setting the SCSI
Device ID” on page 2-2 in t his chapt er for mor e in formati on about assign ing
SCSI IDs.
Install the LED Cable (Optional)
Insert the connector from the drive activity LED on the front panel of the
host to the connector on the FlashPoint as shown in Figure 2-4. This
connector is reversible and may be plugged into the connector in either
direction. If your system has a two-pin LED drive acti vity connector, use the
first two or the last two pins. The following diagram shows the connector
pin-outs.
2-6FlashPoint™ LT BT-930 User’s Manual
Pin 1Pin 4
+5V Gnd Gnd +5V
Figure 2-4. Installing the Optional LED Cable
Step 4: Install external devices and cables
Installation
Figure 2-5. Installing External Devices and Cables
External devices are connected using a 50-pin cable with a high-density
SCSI-2 connector.
Manual No. 30008632-7
Installing Your FlashPoint
Connect one end of the SCSI cable to the adapter’s SCSI connector and the
other end to the SCSI device as shown in Figure 2-5. Devices are attached in
a daisy chain configuration until a maximum is reached. The last device in
the daisy chain must be terminated. All intermediate devices should not be
terminated or should have termination disabled.
Be sure each SCSI device has a unique SCSI ID assigned. Refer to “Setting
the SCSI Device ID” on page 2-2 below for more information about
assigning SCSI IDs.
A Note about SCSI BUS T ermination
The FlashPoint adapter supports both internal and external devices. If more
than two SCSI devices are connected in a SCSI daisy chain (the FlashPoint
adapter card is considered one device in the chain), remove or disable the
terminator resistor pack on the middle devices.
• When attaching internal devices only, the last device in the chain must
be terminated. The FlashPoint adapter automatically terminates the
other end of th e SCSI bus.
• When attaching external devices only, the last device in the chain must
be terminated. The FlashPoint adapter automatically terminates the
other end of th e SCSI bus.
• Both internal and external devices can be attached to the same
FlashPoint adapter. The last device at each end of the SCSI bus (one
internal end and one external end) must be terminated. (See Figure 2-
6.)
The FlashPoint automatically disables its termination to ensure SCSI
bus integrity.
2-8FlashPoint™ LT BT-930 User’s Manual
Installation
Internal End of SCSI Bus
External End of SCSI Bus
SCSI Bus
Figure 2-6. SCSI Bus Ends
• Illegal Configuration (see Figure 2-7)
Illegal configuration involves connecting the FlashPoint adapter in the
middle of a SCSI ribbon cable. The FlashPoint adapter must be
connected at one end of the ribbon cable.
Figure 2-7. Illegal Cabling Configuration
Manual No. 30008632-9
Installing Your FlashPoint
Maximum SCSI BUS Lengths
The SCSI bus may not exceed the maximum lengths listed in Table 2-1. The
limitations listed in this table are for 8-bit data path SCSI d evices. Wide
SCSI (16-bit data path) is not supported by the FlashPoint LT host adapter.
The total length of the SCSI bus is made up of all the cables that interconnect
the FlashPoint to all the devices in the daisy chain configuration including
the length of the internal ribbon cable, if it is used (see Figure 2-8). If the
SCSI bus exceeds the recommended length, the SCSI devices may display
unpredictable behavior.
Table 2-1. Maximum SCSI (8-bit) Bus Configuration Limits
Once the adapter is installed, power up the system. As the system powers on,
the BIOS performs a self test. Any error conditions that arise from the self
test are displayed on the start-up screen. Should you encounter any
conditions that you can not resolve, contact Mylex Customer Service at the
numbers and/or addresses listed in Appendix B of th is manual.
Step 6: Ver if y devices
The FlashPoint adapter comes with an o nboard configuration utility,
AutoSCSI, which resides in Read Only Memory (ROM). AutoSCSI is a
menu-driven utility for configuring Mylex SCSI host adapters. You can use
AutoSCSI to set or change SCSI and BIOS-related configuration parameters.
In addition to simplified configuration, AutoSCSI offers diagnostics. See
Chapter 3, “Adapter and Device Configuration,” for information about how
to use this program to verify the connected devices.
Step 7: Set up hard drives
Most off-the-shelf hard drives are preformatted. If this is not the case, or
your drive requires a low-level format as indicated by error conditions, use
the low-level format utility included with the onboard AutoSCSI utility
described in “Performing a Low-Level Format of a Device” in Chapter 3 of
this manual.
Once the hard drive is low-level formatted, you will need to create a partition
(or multiple partitions) and high-level format the partition(s) to prepare your
drive for operating system installation. Your operating system may
incorporate these partitioning and high-level format functions as part of its
installation or may offer them as separate utilities. For example, DOS
provides FDISK and FORMAT in its utilities suite.
Step 8: Install device driver s
In addition, you may need to install device driver software if your operating
system does not include the required drivers for your installation as
discussed in Chapter 1.
Driver installation usually takes place as part of operating system
installation. Refer to your operating system installation instructions and the
FlashPoint Software User’s Guide for details.
Manual No. 30008632-11
Installing Your FlashPoint
2-12FlashPoint™ LT BT-930 User’s Manual
Chapter 3
Adapter and Device
Configuration
☛
Note
Host adapter configuration is optional. Under normal
operating conditions, you probably won’t need to
perform any adapter configuration. However, if you
need to adjust the adapter’s configuration, the
AutoSCSI utility provides fast and easy configuration
capabilities.
The BIOS on the PCI motherboard automatically configures the following
parameters at power-up:
• Adapter I/O Port Address (Base Address Registers)
• BIOS Address (ROM Base Address)
• Interrupt Channel (IRQ)
Use AutoSCSI to further configure the FlashPoint adapter to suit your
operating environment.
Bringing Up AutoSCSI
AutoSCSI resides in Read Only Memory (ROM). AutoSCSI is a menudriven utility for configuring FlashPoint adapters. In addition to this utilities
simplified configuration, AutoSCSI offers disk utilities.
AutoSCSI is available when the system is first powered up and at every
system reset. Press
When invoked, the AutoSCSI window appears showing a selection dialog
box listing the FlashPoint host adapters that are installed in the system (see
Figure 3-1).
Manual No. 30008633-1
Ctrl+B
at the prompt that follows the BIOS banner.
Adapter Configuration
Figure 3-1. AutoSCSI Adapter Selection
Note
☛
When you exit AutoSCSI after making configuration
changes, the system prompts yo u to reset your sys tem.
The reboot allows changes to the configuration to
become operational.
The Legend at the bottom of the screen show you what keys are enabled for
the window.
Adapter Configuration
1. Highlight the adapter you want to configure. Use the arrow keys to
move up and down the selection list when more than one adapter is
installed in the system.
2. Press <Enter>. The configuration selection dialog box opens on the
display.
3. Select Adapter Configuration and press <Enter>.
3-2FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Figure 3-2. Adapter Configuratio n Op tion s
The functions menu appears on the display. You can select from the
following options:
View/Modify Configuration
•
option allows you to view or change
FlashPoint configuration settings.
Locate Adapter
•
option helps you locate a host adapter in a multiple
adapter configuration. Selecting this options causes the LED on the
selected adapter to blink.
Load Factory Defaul ts
•
resets the current host adapter configuration to
the factory default settings. (See Table 3-3 for a list of default settings.)
4. To view or change the host adapter configuration, highlight View/Modify Configuration and press <Enter>.
The View/Modify Adapter Configuration Window (see Figure 3-3)
allows you to examine and modify the configuration of your host
adapter(s).
Manual No. 30008633-3
Adapter Configuration
Figure 3-3. View or Modify Device Configuration Window
Adapter Configuration Fields
The left side of the window contains a list of the adapter characteristics that
cannot be modified. These information fields are described in Table 3-1.
Table 3-1. Configuration Field Descriptions
OptionDescription
Model
BIOS Version
BIOS Address
3-4FlashPoint™ LT BT-930 User’s Manual
This field identifies the model of the Mylex host adapter.
This field identifies the version of the FlashPoint BIOS. If this
field contains a “-” character, the current host adapter is under
the control of another adapters BIOS.
This field displays the SCSI adapter BIOS starting address in
host memory. In a PCI system, the BIOS is automatically sized
and placed in the memory map. When multiple FlashPoint
adapters are present, only one BIOS is active.
Adapter and Device Configuration
Table 3-1. Configuration Field Descriptions (Continu ed)
OptionDescription
Port Address
PCI Bus #
PCI Device #
SCSI Channel
IRQ
Channel
Termination
This field shows the base address of the registers the host uses
to communicate with the host adapter. Each board and each
channel within the same host system must have a unique I/O
port address to prevent hardware conflicts. On PCI adapters, the
host system’s BIOS assigns the I/O port address during the boot
sequence.
This field shows the PCI bus number.
This field shows the PCI device number
The channel on the FlashPoint LT that is being configured.
This field shows the hardware interrupt line (IRQ) number that
the adapter uses to generate interrupts to the host. The adapter
issues an interrupt whenever it requests attention from the host.
On PCI adapters, the host system’s BIOS assigns the IRQ
value.
This field indicates whether the adapter’s automatic SCSI
termination, SmartTerm is turned on or not. SCSI devices are
daisy-chained together and a terminator is required at each end
of the chain. Should the selected adapter be at t he beginning or
the end of the SCSI chain, this value must be set to AUTO.
Termination is enabled/disabled automatically by the FlashPoint
host adapter.
When there are multiple adapters, the adapter with the highest BIOS address
controls the process of reading data from other adapters for configuration
information.
Modifying Adapter Configuration
The list of options on the right side of the screen may be m odified
To change a value for an option, do the following:
1. Highlight the desired parameter using the arrow keys and press the
<Spacebar>.
2. For example, when you select the SCSI ID parameter and press the
<Spacebar>, a popup menu listing possible values for this parameter
appears. Use the arrow keys to choose a new value from the popup list
Manual No. 30008633-5
Adapter Configuration
(see Figure 3-4) and press the <Enter> key to accept the selected value.
3. For example, when you select the Parity Detection parameter, use the
<Spacebar> to toggle the setting On or Off.
Figure 3-4. SCSI ID Selection Popup Menu
T a ble 3-2 lists the configurable fields and possible values for those fields.
Values shown in
BOLD ITALIC TYPEFACE
indicate the default factory
setting.
3-6FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Table 3-2. Adapter Configur ati on Opti on Descrip tio ns
OptionValueDescription
Adapter SCSI ID 0-
0
Boot Hard Disk SCSI ID
CD-ROM Boot SupportsON
-7The SCSI ID of the Boot Drive. If the value
OFF
Map Removal as Fixed ON
OFF
Floptical SupportON
OFF
BIOS Support for 2+ HDD
ON
OFF
7
Use this option if you need to change the
adapter’s SCSI ID on the SCSI bus. This ID
should remain unchanged, even where
there are multiple SCSI adapters, unless the
adapters are attached to a common SCSI
bus cable.
is set to 0, then BIOS will boot from the first
SCSI ID starting from 0, that is included in
the BIOS scan.
This setting indicates whether a CD-ROM
drive is supported as a boot drive.
If the setting for this parameter is set to
(the default), removable drives (SyQuest or
Bernoulli for example) will not be attached
by the BIOS to a DOS drive at Boot time. If
the parameter is set to
drives will be attached to a DOS drive letter
if media is present at Boot time.
When this option is set to ON, the BIOS
registers and controls floptical devices. Turn
this option
software to control floptical devices.
When enabled, DOS 5.x or later supports
two to eight devices without drivers.
ON
OFF
if you have application
OFF
, removable
INT 13h Extension
Manual No. 30008633-7
ON
OFF
For Windows 95 this parameter supports
devices with capacities greater than 8
Gigabytes.
This setting allows you to enable or disable
parity checking by the adapter on the SCSI
bus. Disable parity checking if it is not
supported by the SCSI device. Refer to the
device manual for more information. Select
ON to enable or OFF to disable parity
checking. Press <Spacebar> to toggle
between selections. There are 8 bits or 16
bits of data plus one or two bits of parity on
a standard SCSI bus.
This setting allows you to enable the power
saving mode feature.
This setting lets you turn off the SCAM
mode feature or lets you set it to Level 1 or
Level 2.
This setting allows you to enable/disable
terminators automatically by FlashPoint’s
SmartTerm logic or force them to OFF.
Press the <Esc> key to exit the display. If you make any configuration
changes, AutoSCSI prompts you to confirm your changes.
4. When you select Yes to save your changes, these changes are stored in
Electrically Erasable Programmable Read Only Memory (EEPROM)
and are recalled upon system reset.
If you enter No, your changes are cancelled.
Locating an Adapter
You can use the Adapter Configuration menu to help you find a specific
adapter in a multiple adapter configuration.
1. To locate an adapter within the computer enclosure, highlight Locate Adapter and press <Enter>. The locating message is displayed on the
screen (see Figure 3-5) while the LED on the adapter blinks.
3-8FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Figure 3-5. Locating the Adapter
NO
2. When you have found the adapter, press any key to return to the
Adapter Configuration menu.
Resetting Factory Defaults
You can reset the adapter parameters to the factory default settings.
1. Highlight Load Factory Default and press <Enter>. For a list of the
settings see Table 3-3. Default values are shown in
TYPEFACE
.
BOLD ITALIC
Figure 3-6. Load Factory Default
2. Respond to the warn ing mess age sho wn in Fi gure 3-7. W hen you select
Yes the default settings are loaded and the system reboots. The factory
default settings take effect after the system reboot.
Manual No. 30008633-9
SCSI Device Configuration
Figure 3-7. Factory Defaults Warning Message
SCSI Device Configuration
To perform device configuration, do the following:
1. Start AutoSCSI, choose an adapter and press <Enter>.
Figure 3-8. SCSI Device Configu ration
2. Use the arrow keys to highlight SCSI Device Configuration and press
<Enter>.
The Device Window opens on the display (see Figure 3-9). The SCSI
Device window provides two major menu options:
3-10FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
• Scan SCSI Bus causes AutoSCSI to perform a SCSI inquiry scan of
the bus. When the scan completes, the device configuration window
displays the name of the device found at each SCSI ID.
• View SCSI Device Handshake displays the host adapter’s
handshake protocol to each device on the bus. The protocol can be
changed in the SCSI device View/Modify Configuration window.
Figure 3-9. SCSI Device Window
The initial device window shows all the devices as unscanned. Select
View SCSI Device Handshake before the devices are scanned to see a
window like that shown in Figure 3-10.
Manual No. 30008633-11
SCSI Device Configuration
Figure 3-10. Unscanned Devices Display
3. Press <Esc> to return to the device list.
4. To view a table of switch settings for an unscanned device ID, use the
arrow keys to highlight an unscanned d evice ID and press <E nter>.
A list of switch settings for the selected device ID is displayed
(see Figure 3-11).
3-12FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Wide Negotiation
: -
Figure 3-11. Switch Settings Window
See Table 3-3 for a list of the switch settings and their values. Default values
are shown in
Use this option if you need to change a SCAM
device’s SCSI ID on the SCSI bus. The
FlashPoint host adapter’s ID is set to 7 by
default.
This is the transfer data rate that the host
adapter will attempt to establish with the target
device.
: If you experience a system hang
Note
condition or data corruption, lower the
negotiated rate to attempt to remedy the
problem. If you are connecting an
Ultra SCSI device be sure to change the
negotiated rate to 20 MB/s.
Use this option to enable or disable SCSI
disconnection for each target device. This
option allows a SCSI device to disconnect
itself when it is not ready for data transfer.
When multiple devices are connected to the
same SCSI bus, SCSI disconnection allows
SCSI devices to perform seek operations in
parallel and improves overall SCSI bus
performance.
The FlashPoint LT does not support wide
negotiation. (Displayed with grey highlight.)
This option allows you to identify the drives
whose motor spin-up is sequentially controlled
by BIOS at power-up. When the disk drive has
a spin-up
jumper enabled that selects Spin-up at PowerOn or Spin-up with Start Unit command, this
ON
parameter must be set to
Setting this parameter to
sequentially issue a Start Unit command at
power-up.
this command.
OFF
prevents BIOS from issuing
.
ON
, allows BIOS to
Note: If the jumper on the device is enabled
and this parameter is set to OFF, although the
drive letter will be recognized the device will
not spin up.
This feature is also useful when you want to
exclude a removable device from BIOS INT
13h support. You must install the DOS ASPI
driver to support any device that is selected to
be ignored by the BIOS scan. When
will identify and register the device at the
specified SCSI ID.
ON
, BIOS
Note: If this device is the boot device, then this
option should be set to on.
3-14FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
To change the configuration parameters, do the following:
1. Use the arrow ke ys to high light a conf igur ation parame ter and press th e
<Spacebar>. Configuration parameters with multiple value choices
display a selection dialog box. Co nfi guration paramet ers with ON/OFF
vales toggle.
2. For example, use the arrow keys to highlight Ne gotiated Rate and press
the <Spacebar> to display the selection dialog box. Use the arrow keys
to highlight the desired selection and press <Enter> to accept the
selection.
3. For example, use the arrow keys to select the Disconnection parameter
and press the <Spacebar> to toggle the value. Press <Enter> to accept
the value.
4. When you have comp lete d changi ng the configuration parameter
settings, press <Esc> to return to the SCSI Device window.
Scanning the SCSI Bus
Selecting the Scan SCSI Bus option causes AutoSCSI to perform a SCSI
inquiry scan of the bus. To perform this scan operation, do the following:
1. Use the arrow keys to highlight Scan S CSI Bus and press <Enter>. The
Scanning message appears on the display (see Figure 3-12).
Figure 3-12. SCSI Bus Scanning Display
2. When the scan is complete, the SCSI Device window updates to show
the result of the SCSI bus scan (see Figure 3-13).
Manual No. 30008633-15
SCSI Device Configuration
Figure 3-13. Scanned Bus Display
Viewing SCSI Device Handshake
To view the SCSI device handshake settings, do the followin g:
1. Use the arrow keys to highlight Vi ew SCSI Device Handshak e and press
<Enter>.
2. The SCSI Device Handshake window opens (see Figure 3-14). The
transfer rate initially requested for the device and the actual transfer
rate of the scanned device are listed in this window. Notice that the
requested and the actual transfer rates may be different. If during the
transfer rate negotiation, the device is found to be incompatible with
the requested transfer rate, an acceptable rate is negotiated for the
device.
3-16FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Figure 3-14. SCSI Device Handshake Window
3. Press <Esc> to exit the window and return to the SCSI Device window.
Modifying Device Configuration
To make adjustments to the device configuration, do the following:
1. Use the arrow keys to highlight the device you wish to modify and
press the <Spacebar>. The Device Configuration menu appear as
shown in Figure 3-15.
Manual No. 30008633-17
SCSI Device Configuration
Figure 3-15. Device Configuration Men u
2. Highlight View/Modify Configuration and press <Enter>. The View/
Modify Device Configuration window appears (see Figure 3-16).
The left side of the screen shows the static characteristics of the
selected device. These characteristics can not be modified. See
Table 3-4 for a brief description of these parameters. Refer to the
owner’s manual of your device for further information about the
contents of this display.
Table 3-4. SCSI Device Static Parameters
ParametersDescription
Vendor IDThe name of the device manufacturer.
Product IDThe device’s model name.
Firmware VersionThe device’s firmware version number.
ANSI VersionThe SCSI level of the device.
Synchronous ModeIndicates if synchronous mode is supported by the device.
Wide NegotiationIndicates if wide negotiation is supported by the device.
Command QueueIndicates if command queue is supported by the device.
Device TypeThe type of device.
Capacity (MB)The number of megabytes of storage in the device.
Sector Sz (Bytes)The sector size of the device in bytes.
SCAMIndicated if SCAM is supported by the device.
Transfer Rate The data transfer rate of the device shown in MB/sec.
3. Use the <Page up> and <P age do wn > k e ys to change the display to the
other SCSI devices on the SCSI bus.
The right side of the screen sho ws the de vices confi guration paramet ers
that can be modified. See Table 3-3 for a list of the parameters and their
values. Default values are shown in
BOLD ITALIC TYPEFACE
.
To change the configuration parameters, do the following:
1. Use the arrow keys to highlight a parameter and press the <Spacebar>.
Parameters that can be toggled ON and OFF change when selected.
2. SCSI ID and Negotiated Rates have selectable values. Highlight the
Manual No. 30008633-19
SCSI Device Configuration
desired entry and press the <Spacebar>. A popup menu appears listing
the selectable values. Use the arrow keys to highlight the desired value
and press <Enter> to accept the highlighted value.
3. When you have completed changing the parameters, press <Esc> to
return to the SCSI Device window.
4. When you have comp lete d viewing and modifying dev ice
configuration, press <Esc> to return to the Device Co nfiguration menu.
Locating a Device
You can use the Device Configuration Menu to help you find a specific
device within your configuration.
1. To locate a device, highlight Locate Device and press <Enter>. The
locating message is displayed (see Figure 3-17) while the LED o n the
device blinks.
Figure 3-17. Locating the Device
2. When you have fou nd t he device, press any key t o return to the De vice
Configuration menu.
Verifying a Device
The Verify option scans the media of a selected device. Use this option to
verify that your hard drive is operable. To verify the format of a SCSI disk
device, do the following:
1. Highlight Verify and press <Enter>. The verification confirmation
dialog box (Figure 3-18) appears.
Figure 3-18. Verif yin g the De vice
3-20FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
2. Select Continue to perform the device verification operation. Select
Cancel to cancel the operation and return to the Device Configuration
menu.
Performing a Low-Level Format of a Device
You can perform a low-level f ormat of a de vice usin g the For mat option from
the Device Configuration Menu.
1. Highlight Format and press <Enter>. The format confirmation dialog
box appears (Figure 3-19).
Figure 3-19. Device Formatting Confirmation
2. Select Continue to perform the formatting operation. Select Cancel to
cancel the operation and return to the Device Configuration menu.
WARNING
,
The device formatting operation erases any
information that may be stored on the disk drive.
Do not confirm this operation if there is any data
on the device that you do not wish to erase. Before
formatting, make sure that all necessary data is
backed up.
If you make any configuration changes before you leave the Device
Configuration window, AutoSCSI prompts you to confirm your changes.
When you select Yes, any configuration changes you may have made are
stored in the serial EEPROM. If you enter No, your changes are cancelled.
Manual No. 30008633-21
SCSI Device Configuration
3-22FlashPoint™ LT BT-930 User’s Manual
Chapter 4
Troubleshooting
Troubleshooting Guidelines
If you experience a problem with adapter operation when all the installation
steps are completed, refer to the following guidelines.
Check the Installation Procedures
• Be sure all connectors are firmly seated.
• Check the orientation of the SCSI cable. Be sure that Pin 1 o n the cable
matches Pin 1 on the adapter/SCSI device connector.
• Check that the adapter and attached devices have unique SCSI IDs.
• Be sure that the SCSI ID for the boot hard drive is the same as the ones
in the AutoSCSI option. If the ID 0 (zero) is specified in that option,
BIOS determines the boot drive by scanning SCSI devices starting
from ID 0. If the boot drive number is higher than the other drive,
change it to a lower value.
• Be sure that you’ve followed SCSI termination rules.
• Check that you have correctly set the CMOS hard drive option to not installed in your system SETUP file.
Verify Host Adapter Configuration Settings
☛
Note
Although IRQ and BIOS Addresses are autom atically
configured in a PCI system, differences in PCI bus
implementation may result in conflicts among
adapters from more than one manufacturer.
• Check the adapter’s IRQ setting. Verify that each installed card has a
unique IRQ value. There may be a conflict with ISA (non-PCI)
adapters. If this occurs, you must change the non-PCI adapter’s IRQ
setting.
Manual No. 30008634-1
Troubleshooting Guidelines
For example, you have installed the ASPI DOS driver in the
CONFIG.SYS file and are attempting to boot from a SCSI disk drive.
The system begins the boot sequence, the b anner is displayed , attached
SCSI devices are recognized and posted on the display. A message is
then displayed indicating that th e SCSI DOS driver is being installed,
however, the system appears to suspend operation with no further boot
activity. In this sequence of operation, BIOS does not require IRQ
support, so it proceeds without problem. The DOS driver requires the
IRQ and quickly stops operation after being installed because of a
possible IRQ conflict.
• Verify AutoSCSI configuration. If you have changed adapter SCSI-
or BIOS-related parameters via AutoSCSI, use the Load Factory Default option on the AutoSCSI Adapter Configur atio n Menu to return
the board to factory-set defaults. Check that you have selected
operating parameters that do not conflict with those of other installed
adapters before re-entering your changes.
Check Device Driver Compatibi lity
• Check that you have installed no more devices than your operating
system or driver can handle. For example, pre-DOS 5.0 versions of
DOS can handle only two hard drives. To handle more devices, you
must install additional drivers.
• Under DOS, be sure that you ha ve installed dri v ers appropr iate for each
installed device. For example, you cannot operate a CDROM device
without installing a CDROM driver for it. Mylex provides a DOS
CDROM driver. Refer to driver installation for further details.
• Be sure you have compatible device driver software installed.
Verify SCSI Device Configuration and Connectivity
Verify that the SCSI cabling is correctly attached and that the adapter can
communicate with a selected device by performing the following:
• Check the adapter’s ability to communicate with attached devices.
Invoke AutoSCSI, and select the SCAN SCSI Bus option on the SCSI
Device list. This option will scan the SCSI bus displaying the message
shown in Figure 4-1. When the scan operation is complete, it registers
all the SCSI devices and displays the device information. If the device
4-2FlashPoint™ LT BT-930 User’s Manual
Troubleshooting
information is displayed without error, then the adapter is properly
communicating with the SCSI devices.
Figure 4-1. Device Scanning Dialog Box
If an attached SCSI device is not recognized, verify that each device
has a unique SCSI ID. The host adapter is set to SCSI ID 7 by default.
Disable Fast Transfer Rate. Some SCSI de vi ces may not be capable of
negotiating a data transfer rate of 20 /10 MBytes/sec. If a d evice cannot
support the higher rate, it is supposed to reject that value and propose a
lesser value it can support. Some older SCSI devices when requested to
negotiate at 20/10 MBytes/sec will halt operation. Try selecting a lower
negotiating data transfer rate or set the requested transfer rate to Async
in the View/Modify Device Configuration menu.
Motor Spin -U p. Some SCSI disk devices may not be configured to
spin-up on power-on or upon reset. This will cause an error if the
operating system attempts to access this device. When this occurs,
enable the Motor Spin-Up option in the AutoSCSI View/Modify
Device Configuration menu. If this option is enabled and the selected
device does not require this option to be enabled, the device will
probably ignore it.
Power. Be sure that all external SCSI devices a re secur ely co nn ected to
a power source.
Troubleshooting Startup
At system startup, the FlashPoint adapter performs a self-test, runs tests on
the SCSI bus, and performs SCAM on the SCSI bus devices. As these
operations are executing, screen messages appear briefly. When all the
operations are complete, a BIOS installation completion message is
displayed and your system should continue to boot. If the startup operations
do not complete successfully, an error message may be displayed. There are
also conditions under which an operation will not complete successfully and
the system will hang before an error message can be displayed. System hang
instances and error messages are shown below. Where possible, problem
resolution procedures are included.
Manual No. 30008634-3
Troubleshooting Startup
NO BIOS BANNER IS DISPLAYED
The system does not find the adapter. Make sure the adapter is properly
installed in a busmaster slot.
SCANNING BUS...CARD XXX, SLOT X, BUS:XXX PORT XXXXX
If the system hangs with this message, the bus scanning operation did not
complete successfully. Check the following:
• Verify all the cables and connectors are firmly seated and properly
installed.
• Verify there are no reversed cable connections.
• Verify the FlashPoint adapter is installed in a busmaster slot.
• Verify all the devices, including the FlashPoint adapter, have unique
SCSI IDs.
BIOS NOT INITIALIZED.
NO SCSI TARGETS RESPONDED.
This message indicates that no SCSI devices have been detected:
• Verify the SCSI devices are properly cabled and connected.
• Verify all external devices are powered on.
• Verify all internal devices are connected to the power supply.
This message indicates that the SCSI bus has failed the diagnostic test. Test
failure is often due to improper connections or bad cables. Do the following:
• Turn the system off and then on again. This action retries the diagnostic
test.
• Verify all cables and connectors are properly installed.
• Verify there are no reversed cable connections.
ENTERING CARD DIAGS/INIT, CARD:00
ENTERING SCSI BUS RESET PROTOCOL.
ENTERING SCSI BUS INTEGRITY TEST.
ENTERING SCAM SELECTION.
If the system hangs at this point in the diagnosti c tests, ch eck the following:
• There may be a SCSI ID conflict, verify that each SCSI device has a
4-4FlashPoint™ LT BT-930 User’s Manual
Troubleshooting
unique SCSI ID.
• The SCSI bus may be improperly terminated. Verify that the bus is
terminated properly.
This message indicates a RAM diagnostic failure. Problems may include the
following:
• The adapter card is bad. Stop and restart the system to retry the
operation.
• The adapter card is not compatible with the system. Ch eck to see if
your system uses the VIA Chipset. If it does, revision CF or earlier is
not compatible with the adapter. CG or later is compatible with the
adapter.
• The BIOS is not PCI compliant.
ERROR: NON-PCI COMPLIANT SYSTEM BIOS, PLEASE UPGRADE.
This is not an adapter-related problem. Call the motherboard manufacturer
for information on upgrading your system BIOS.
Manual No. 30008634-5
Troubleshooting Startup
4-6FlashPoint™ LT BT-930 User’s Manual
Questions & Answers
Q. Why does the “NO ROM BASIC” message appear
when booting up?
A. The DOS partition may not be activated, run the MS DOS FDISK utility
and set the partition active. Refer to your MS DOS reference manual for
specific instructions on activating a DOS partition using the FDISK
command.
Q. Why is the message “Missing Operating System”
displayed during boot, but the hard drive is still seen
by the controller?
A. Check for the active partition. High level format the partition with the
“format C:/s” option. Note, this will erase any data currently on yo ur hard
drive. If the drive was previously used on another controller, you may need
to perform a low-level format and then prepare the drive with DOS Fdisk
and Format utilities. If the mapping mode has been changed since the last
hard disk partitioning, perform another Fdisk an d Format.
Q. My system displays a “Har d Disk F ailure” messa ge
during boot up, what can I do to correct it?
A. Check all cables and drive jumpers. Make sure the drive for the C: drive
is “Type 0" or “Not Installed” in System CMOS if no IDE is installed.
Q. When my system boots up, the banner shows 6
drives, but I only have 1 drive. What is wrong?
A. Check that the drive is not the same SCSI ID as the SCSI controller,
which defaults to ID 7. Make sure your drive is set to SCSI ID 0.
Manual No. 3000863Q&A-1
Q. How can I use a CDROM drive wi th Mylex contr oller
card in MS-DOS?
A. In DOS, make sure the SCSI ID for the CD-ROM is higher than the disk
SCSI ID. Connect the CD-ROM in the SCSI chain so that it is properly
terminated. Then add these two lines to your CONFIG.SYS.
Q. When I load the FLASHPT.SYS driver in the DOS
CONFIG.SYS, the system hangs.
A. Do followings:
1. Make sure the IRQ settings are configured properly. In the system
CMOS under PCI option, there is an IRQ setting. Make sure an IRQ is
being assigned to the Mylex slot.
2. Try a different IRQ. For example, i f you are using IRQ 12, try IRQ 11.
Make note of the first requirement above, make sure it applies when
you try a different IRQ.
3. Get another copy of the latest versio n of FLASHPT.SYS and try it. The
original file may be corrupted. Copies of this file can be obtained in our
BBS, FTP site, or WWW page.
Q. Why I am getting slow transfer times with my new
FAST SCSI-2 hard drives .
A. Make sure the drive is jumpered FAST SCSI-2 and active termination.
Also check that the controller has both Synchronous Negotiation and Fast
Data Transfer enabled.
Q&A-2FlashPoint™ LT BT-930 User’s Manual
Q. I am connecting a removable drive to the Mylex
adapter in DOS. What device drivers do I need to
load?
A. In DOS, you need to load DOS Manager drivers in CONFIG.SYS as
follows:
After that run BTFDISK program to create the partition on the drive
connected to second card and use the DOS FORMAT command to format
the drive.
Q. I am connec ting a SCSI tape drive to the Mylex
adapter. What device driver do I need to load?
A. You need to load DOS Manager driver in CONFIG.SYS as follows:
device=c:\path\flashpt.sys /d
You also need tape backup software.
Q. I have a large capacity (more than 1GB) drive.
When I run FDISK, it recognizes only 1 GB capacity.
What is the problem?
A. Make sure you enable the DOS > 1 GB switch on the adapter. If you plan
to run NetWare, leave this option off and create your DOS partition in the
first 1G.
Q. I have a floppy tape backup and it runs very slowly
with the Mylex SCSI adapter. What should I do?
A. When you load DOS manager, use the “/n04” switch to reduce bus on
time from default 11us to 4us.
Manual No. 3000863Q&A-3
Q. Why does my system lock up on bootup after
connecting to an external SCSI device?
A. Double check for proper SCSI bus termination and check connections and
cabling.
Q. I added a new SCSI device to one of the Model C
SCSI host adapter s. Either it is not seen or the system
hangs when the host adapter BIOS tries to scan it. Do
I have the proper SCSI bus termination?
A. This problem occurs mainly because the new device is not SCSI II FAST.
You need to change the Enable Fast Transfer option to No in the AutoSCSI
Configuration Menu. Disable the Enable Synchronous Negotiation option
too, if it is not supported by the device.
Q&A-4FlashPoint™ LT BT-930 User’s Manual
Appendix A
Small Computer System
Interface (SCSI)
This appendix describes the Small Computer System Interface terms. It is
provided to help you understand the concepts related to SCSI.
What is a host adapter?
A SCSI host adapter is a printed circuit card that provides a SCSI bus
interface to the SCSI devices installed in a computer system. The FlashPoint
host adapter has both internal and external SCSI connectors supporting both
internal and external SCSI peripheral devices.
What does SCSI stand for?
SCSI stands for Small Computer System Interface. SCSI is a computer bus
interface standard that allows a variety of computer peripheral devices such
as disk drives, CD-ROM drives and tape drives to interface to a host
computer. SCSI-1, SCSI-2 and SCSI-3 are different version of the SCSI
protocol standard.
• SCSI-1 is the original standard that defines the SCSI interface. This
standard includes the definition of a command set, the electrical
characteristics of the SCSI bus, and a 5 megabytes per second data
transfer rate.
• SCSI-2 adds features to the standard including, SCSI linking,
command queueing, and support for additional SCSI peripheral
devices. The SCSI-2 standard also includes the following:
• Fast SCSI is a SCSI data transfer standard that allows up to 10
megabytes per second data transfer on the SCSI bus.
• Wide SCSI provides data transfer at 16-bits for faster data
throughput. Up to 20 megabytes per seco nd is suppo rted on F as t and
Wide SCSI host adapters.
Manual No. 3000863A-1
What is the SCSI bus?
• SCSI-3 adds more features including Ultra SCSI, SCAM, optional Pcable, the Wide SCSI bus specification that defines an extended
number of devices, support for fiber channel hardware, and a serial
channel interface. It also allows transfer rates of 20 megabytes per
second.
What is the SCSI bus?
A SCSI bus is one or more SCSI peripheral devices and a host adapter
connected together by cables in a daisy chain configuration. The SCSI bus
may include both internal and external devices on one bus.
• A Narrow SCSI bus may have up to eight devices. The host adapter
counts as one device.
• Wide SCSI supports up to 16 devices. Note, however, that Wide SCSI
is not supported by the FlashPoint LT host adapter.
What are the SCSI bus length limitations?
The SCSI bus maximum length is determined by the data transfer rate and
the number of devices in the configuration. Table A-1 lists the data transfer
rates, the maximum number of devices and the maximum allowable cable
lengths for each.
Table A-1. Maximum SCSI Bus Configuration Limits (Narrow Only)
Remember when measuring the length of the SCSI bus, you must include all
the connecting cables including the internal cable if it is used to connect
internal devices.
A-2FlashPoint™ LT BT-930 User’s Manual
Small Computer System Interface (SCSI)
What is a Daisy Chain Configuration?
A daisy chain is where the bus is created by attaching the first device in the
chain to the second device and the second device to the third device and so
on until all the devices are chained together.
What is a SCSI ID?
A SCSI ID is a unique identifying number ranging from 0 to 7. (0-15 for
Wide SCSI) This number is assigned to a SCSI device on the SCSI bus. The
SCSI ID identifies the device and determ ines the priority of the de vice on the
SCSI bus. The priority of the de v i ce on th e bus is important when more than
one device attempts to access the bus at the same time. The higher the SCSI
ID number the higher the priority of the device during bus access. The
FlashPoint adapter is preassigned SCSI ID 7, giving it the highest SCSI bus
priority.
What is termination?
T ermination is an electrical characteristic of a SCSI bus. In order for devices
to transmit and receive data and signals reliably over the SCSI bus, the bus
must be properly terminated at both ends.
Devices can be terminated in a variety of way:
• The FlashPoint adapter supports SmartTerm. This means that the
FlashPoint adapter determines where it is located in the daisy chain and
either enables or disables its own termination as required.
• Peripheral devices can be terminated using a sev eral dif feren t methods.
Some require termination plugs, thumb wheel setting, and/or DIP
switches. Refer to the documentation that accompanies the device to
determine what the termination method is. If the device occupies either
end of the daisy chain, it must be terminated properly in order for the
SCSI bus to function properly.
What kinds of terminators are there?
For external de vices there are SCSI-1 and SCSI-2 type terminators. Standard
SCSI-1 terminators fit into Standard SCSI-1 connector receptacles. SCSI-2
terminators fit into SCSI-2 receptacles.
Manual No. 3000863A-3
What are SCSI Cables and Connectors?
Internal devices may be terminated using cable terminators, however it is
more likely that an internal device will use some sort of other method of
termination like a resistor pack or a jumper.
When determining how to terminate a de v i ce, e xam ine the device and check
on the manufacturers suggested termination method as described in the
product documentation.
The last device in the chain must be terminated. The terminator may be a
SCSI-2 type terminator or Standard SCSI-1 (Centronics).
The cable to the device may need a SCSI-2 type plug or a Standard SCSI
(Centronics) type plug.
It is recommended that you use active terminators rather than passive
termination.
What are SCSI Cables and Connectors?
There are several types of SCSI cables and connectors.
Cables are used between the devices in a SCSI bus to create the electrical
pathway that connects the devices to the host adapter. The FlashPoint LT
adapter provides for both internal and external device attachment.
Internal Connections. The FlashPoint LT adapter’s internal connector is a
standard 50-pin internal SCSI connector that provides attachment for the 24inch ribbon cable with two additional de vice connectors. T his ribbon cable is
provided with the adapter. You can connect two internal devices to the
adapter using this cable. Remember when using this cable to connect internal
devices to the FlashPoint adapter, the last device on the cable must be
terminated.
External Connections. The FlashPoint LT adapter’s external connector is a
SCSI-2 50-pin connector. In order to correctly cable devices, you must
examine each device to determine what type of connectors need to be
accommodated.
For example, if the peripheral device you want to attach to the FlashPoint
adapter has standard SCSI 50-pin (Centronics) connectors, you will need to
purchase an adapter cable that has a SCSI-2 connector on one end (to attach
to the FlashPoint adapter external connector) and a SCSI 50-pin (Centronics)
connector on the other end to attach to the adapter.
A-4FlashPoint™ LT BT-930 User’s Manual
Small Computer System Interface (SCSI)
Each device needs to be examined to determine what type of connector is
required. SCSI cables come in a variety of connector combinations so that
the SCSI bus may be made up of a combination of device types with cable
adapting for the differences between devices.
Manual No. 3000863A-5
What are SCSI Cables and Connectors?
A-6FlashPoint™ LT BT-930 User’s Manual
Appendix B
Mylex Customer Support
Mylex provides a number of services for customer convenience. These
services include the following:
• You can reach Mylex’s Technical Support at 510-608-2400, Monday
through Friday, from 6:00 a.m. to 6:00 p.m. Pacific Time. Before you
call, please complete the Product Support Record on the back of this
page.
• Mylex’s Technical Support Bulletin Board System (BBS) is available
24 hours a day, seven days a week. It provides information on software
updates and new releases, technical bulletins, and other information.
You can reach the BBS at 510-793-3491. For access, all you need is a
modem and communicati o ns s oftware of your choi ce. S et you r modem
to 14.4 k baud, 8 data bits, 1 s top bit and no parity. Once connected, log
on with your name and a password of your choosing.
• FAX requests will be answered within 24 hours upon receipt at Mylex.
Send your FAX requests to 510-745-7715. Please include a completed
Product Support Record (on the back of this page).
• E-Mail Addresses:
Internet: support@mylex.com
FTP Site: ftp.mylex.com
WWW Home Page: http://www.mylex.com
• US Mail:
Mylex Corporation
34551 Ardenwood Blvd.
Fremont, CA 94555-3607
• To order Mylex software or additional manuals, call 510-608-240 0.
Manual No. 3000863B-1
Product Support Record
Product Support Record
The information on this page should be compiled and provided to your
supplier in writing to obtain technical support assistance. This will enable
your supplier to respond more rapidly and more appropriately to your
problem.
Mylex Product:
Mylex Product No: _______________________________________________
Serial Number: _________________ ___________________________ ______
Date of Purchase: _____________ _____________ ______________________
Firmware Version Number:__________ ___________________________ ____
BIOS Version Number: ___________ _____________ ____________________
System Manufactur er:_____________________________________________
System Model and Speed:__________________________________________
_______________________________________________________________
System BIOS Manufacturer: _________ ___________________________ ____
Memory in System:_______________________________________________
Hard Drives on System: ________________________________ ___________
Thank you for pu rchasing this Mylex product fo r your comput er system. I n addition to this high-qu ality produc t,
your purchase entitles you to the warranty coverage set forth herein. In order to provide this warranty coverage, and
to indicate yo ur ac cept ance of thi s warr an ty, we must have the att ache d Warranty Registrat ion Ca rd comp le ted and
returned to us within 15 days of your pu rch ase. Also, in ord er for us to pr ovide you t he high est level of service, we
must know where you purchased your MYLEX product.
Three Y ear Limited Warranty
If at any time dur in g the th irt y six mon th pe ri od imme di atel y f ollowing the date of ori gi nal pu rch as e of the MYLEX
product enclosed herewith (the “PRODUCT”) you discover one or mo re defects in the material or workma nship,
MYLEX will repair, or at MYLEX’s sole option, replace the PRODUCT. If the PRODUCT fails to operate at any
time within seven days after the date of its original purchase, it will be replaced by MYLEX. Such repair or replacement will be your sole remedy against MYLEX, and MYLEX ’s only liabi li ty to you, for any failure or malfunction
of the PRODUCT. The warranty set forth in this paragraph will be void if:
1. The PRODUCT has been installed in an improper manner or in an improper operating environment.
2. The PRODUCT has been modified or repaired by any party other than MYLEX or a MY LE X fact ory authorized
service center.
3. The PRODUCT has been damaged.
Some MYLEX products will have a Warranty Expiration Date lab el affixed to the product itsel f. When pre sen t, the
warranty period will extend through the last day of the month indicated.
This warranty will not appl y to, and MYLEX provides no warran ty for, any BIOS, software, ROM-based firmware,
or any other PRODUCT developed or manufactured by any third party, whether included with this PRODUCT or
not. Such warranty or warranties as are provided by t hird parties, to the exten t permitted thereby, shall be made
available, and are hereby assigned, by MYLEX to the purchaser of this PRODUCT.
If MYLEX issues a revision to the BIOS, firmware or software included with this PRODUCT within 30 days of
your purchase, MYLEX will replace such firmware at no charge except handling fees.
Out of Warranty Service
Mylex products which are inelig ible for warran ty service may be servi ced by MYLEX according t o our standard
price list, as modified f rom time to ti me. A current copy of the standa rd price list i s available from the Technical
Support Department.
Limitation of MYLEX Liability
MYLEX’s liability arising from the sale, use and disposition of this PRODUCT shall in no event exceed the amount
paid to MYLEX for this PRODUCT. MYLEX assumes no liability for damages arising from the use or failure of
any MYLEX product. The WARRANY DESCRIBED ABOVE CONSTITUTES THE ONLY WARRANY MADE
BY MYLEX. MYLEX EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND
WHATSOEVER, WHETHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY
EXCLUDED. IN NO EVENT WILL MYLEX BE LIABLE FOR INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOSS OF DATA, USE, OR INCOME), EVEN IF
ADVISED OF SUCH DAMAGES IN ADVANCE. Your sole remedies shall be as provided herein.
P/N: 772058-036-98Printed in U.S.A.
Returned Merchandise Procedures
If you suspect that there is a defect in the ma terial or workmanship o f this PRODUCT, you should contact the person or company from which you purc hased it. That person or company may be able to solve the problem and if not,
will be able to contact us for t ec hni c al assist ance or repair.
If it is determined that the PRODUCT must be returned to MYLEX for repair or re placement, contact MYLEX’s
Technical Support Department at 510-608-2 400 before it is returned. Each retur ned item must have a separate
Return Merchandise Authorization (RMA) number, provided by MYLEX.
The following rules apply to all returned items:
1. The PRODUCT must be returned either in its origin al packagin g or in othe r packagi ng which is appropria te for
the PRODUCT and the manner of shipment, and the RMA number must be displayed prominently on the outside of
each such package.
2. If a PRODUCT is determined to be i neligi ble for warra nty service, t he c ustomer will b e no tified before any fur ther action is taken with the PRODUCT.
3. MYLEX will not be responsible for any loss or damage to property shipped with the RMA PRODUCT not originally sold by MYLEX (e.g., co processor chips, periphera l b oa rds, memory modules, enclosures, power supplies, or
any other accessories or atta ched items).
4. Any item returned to MYLEX wit hout a valid RMA number will be returne d to t he shipper.
Products shipped to MYLE X must be shipped or mailed at the shipper’s risk, freight prepaid, to the address bel ow.
Mylex Corporation
34551 Ardenwood Blvd.
Fremont, California U.S.A.
94555-3607
Mylex will pay for return freight via suc h ca rrier as MYLEX shall deem approp ria te .
Technical Support
Technical support, to assist you in re solvin g probl ems with M YLE X prod ucts, is now available throu gh M YLEX’s
Technical Support Department. In the U.S.A. , the Technical Support Department can be reac hed by telephone at
(510) 608-2400 or by FAX at (510) 745-7715. Current hours of opera tion, which are subject to change, are from
6:00 a.m. to 6:00 p.m. Pacific Time, Mondays through Fridays, excluding U.S.A. national holidays.
Included with the shipment of mo st MYLEX products is a System Prob lem Repo rt (SPR) form . When conta cting
the Technical Support Department for assistance with an installation or compatibility problem, we recommend that
this form be complet ed and sent by facsimile or mail to MYLEX. Completion of t his form will allow our Technical
Support Department to solve most te chnical problems expeditiously.
Mylex will make reasonable e fforts to address compa tibility proble ms which ma y arise with respe ct to third pa rty
products, but shall not be responsible for the compa tibility of its products with the products of any third p ar ty. Customers are advised to verify each products compatibility with their installation before committing to any particular
procurement plan.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.