Mylex FlashPoint BT-930 User Manual

FlashPoint™ LT
PCI to SCSI Host Adapter
BT-930
Installation Guide and
User Manual
Part Number 3000863 Rev. D
© Copyright 1997 Mylex Corporation.
All Rights Reserved.

Notice

This Manual describes the Mylex FlashPoint™ LT BT-930 PCI to SCSI Host A dapter. Although reasonable efforts have been made to as sure the accuracy of the information
contained herein, this publication could include technical inaccuracies or typographical errors. Mylex Corporation expressly disclaims liability for any error in this information, and for damages, whether direct, indirect, special, exemplary, consequential or otherwise, that may result from such error, including but not limited to loss of profits resulting from the use or misuse of the manual or information contained therein (even if Mylex Corporation has been advised of the possibility of such damages). Any questions or comments regarding this document or its contents should be addressed to Mylex Corporation at the address shown on the cover.
The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with local law:
MYLEX CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Some states do not allow disclaimer of express or implied warranties or the limitation or exclusion of liability for indi re ct, special, e xemplary, incidental or consequential damages in certain transactions; therefore, this statement may not apply to you. Also, you may have other rights which vary from jurisdiction to jurisdiction.
Information in this publication is subject to change without notice and does not represent a commitment on the part of Mylex Corporation. Changes may be made periodically to the information herei n; th ese changes will be incorporate d in new editions of the publication. Mylex Corporation rese rv es th e ri ght to mak e i mpro v emen ts and/ or cha nges a t an y time in the product(s) and/or program(s) described in this publication.
It is possible that this publication may contain reference to, or information about, Mylex Corporation prod uct s (machines and pro grams), programming or services that are not announced in your country. Such references or information must not be construed to mean that Mylex Corporation inte nds to an no unce, provide, or make av a ilable such Mylex products, programming, or services in your jurisdiction.
Requests for technical information about Myl ex Cor poration products should be made to your Mylex authorized reseller or Mylex marketing representative.
Mylex is a registered trademark of Mylex Corporation. FlashPoint and MultiMaster are trademarks of Mylex Corporation.
Microsoft and MS-D O S are registered trademarks of Microsoft Corporation. Windows, Windows 95, and Windows NT are trademarks of Microsoft Corporation.
SCO and UnixWare are registered trademarks of The Santa Cruz Operation, Ltd. Novell and NetWare are registered trademarks of Novell, Inc.
Unless otherwise noted, companies, names and data used in examples herein are fictitious.

Class B Compliance

THIS DEVICE COMPLIES WITH PART 15 OF THE F CC RULES . OP ERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are de signed to provide reasonable protection against harmful interference in re sidential installation s. This equipment generates, uses, and can r a diate radio frequen cy energy, and if not installed and used in accordance with the instruc tions, may cause harmful interfere nce to radio communications. However, there is not guarantee that interference will not occur in a particular installation.
If this equipme nt doe s cau se interference to rad i o or te lev i s io n equipment recept ion , which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Move the equipment away from the receiver
3. Plug the equipment into anm outlet on a circuit different from that to which the receiver is powered.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional sugge st ion s.
All external connections should be made using shielded cables..
m Caution
Only equipment certified to comply with Class B (computer input/output devices, terminals, printers, etc.) should be attached to this equipment.
Any changes or modif ications to the equip ment by the user not expressly approved by the grantee or manufacturer could void the user’s authority to operate such equipment.

Declaration of Conformi ty

Manufacturer’s Name: Mylex Corporation Manufacturer’s Address: 34551 Ardenwood Blvd.
Fremont, CA94555-3607 USA
Declares that the product: Mylex FlashPoint Product Name: PCI to SCSI Host Bus Adapter
Model Number(s): FlashPoint LT BT-930 Year of Manufacture: 1997
Conforms to the following Product Specification(s): EMC: EN 50081-1:1992/EN 55022:1992 Class B
EN 50082-1:1992 - Generic Immunity EN 61000-4-2:1995,4kV CD, 8kV AD
EN 50140:1995, 3 V/m, 80 - 1000 MHz, 80% EN 61000-4-4:1995, 0.5kV I/O, 1kV Power
Supplementary Information:
The product herewith complies with the requirements to the EMC Directive 89/336/EEC
Declaration that the equipment specified above conforms to the above directive(s) and standard(s) is on file and available for inspection at the manufacturer’s address cited above.

Community of Europe

CE mark is rated for the FlashPoint LT BT-930 PCI to SCSI Host Adapter as follows: CISPR 22 Radiated Emission EN55022, EN5082 -1 Generic immunity standard for the following:
IEC 801-2 ESD, IEC 801-3 Radiated, and IEC 801-4 EFT/Burst Warning! This is a Class B product. In a residential environment this product may cause radio
interference, in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgren zwertklasse B. In Wohnbereichen können bei
Betrieb dieses Gerätes Rundfunkstöru ngen aufreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Avertissement! Cet appareil est un appareil de Classe B. Dans un environnement résidentiel cet
appareil peut provoquer des brouilla ges radioélectriques. Dans ce cas, il peut être demandé à l’utilisateur de prendre des mésures appropriées.

About This Manual

This installation guide covers information necessary to install and configure the Mylex FlashPoint LT PCI to SCSI Host Bus Adapter.

Conventions

Throughout the manual, the following conventions are used to describe user interaction with the product:
bold The user must enter the bold text exactly as shown Press the Enter key
Enter Press the key labeled “Enter” (or “Delete”, etc.) File, Run Select the Run option from the pull-down menu
activated when the File menu pad is selected
Note
Supplementary information that can ha ve an effect on system performance
m Caution
Notification that a proscribed action has the potential to adversely affect equipment operation, system performance, or data integrity
,
WARNING
Notification that a proscribed action will result i n equipment damage, data loss, or personal injury
definitely
Contents
Chapter 1
Introduction
Configuration ..................................................................................... 1-2
Features ............................................................................................ 1-2
Hardware Requirements ....................................................................1-3
Software Requirements .....................................................................1-4
Device Driver Needs ..................................................................1-4
Supported Operating System/Driver Support .............................1-4
Reference Documents .......................................................................1-6
Specifications ....................................................................................1-6
Chapter 2
Installation
What’s Covered in This Section ........................................... .............2-1
Unpacking .........................................................................................2-1
Warranty Information .................................... ..... ...... ...... .............2-2
Installation Tools ...............................................................................2-2
Setting the SCSI Device ID ...............................................................2-2
SCAM Support ...........................................................................2-3
Terminating SCSI Devices ................................................................2-3
Installing Your FlashPoint ..................................................................2-4
Step 1: Prepare the host system and the adapter ......................2-4
Step 2: Install the adapter ..........................................................2-5
Step 3: Install internal devices and cables .................................2-5
Install the LED Cable (Optional) .................................................2-6
Step 4: Install external devices and cables ................................2-7
A Note about SCSI BUS Termination ................................ ...... ..2-8
Maximum SCSI BUS Lengths ..................................................2-10
Step 5: Power up the System ...................................................2-11
Step 6: Verify devices ..............................................................2-11
Step 7: Set up hard drives ........................................................2-11
Step 8: Install device drivers ....................................................2-11
Chapter 3
Adapter and Device Configuration
Bringing Up AutoSCSI .......................................................................3-1
Adapter Configuration .......................................................................3-2
Adapter Configuration Fields ......................................................3-4
Manual No. 3000863 vii
Modifying Adapter Configuration ................................................3-5
Locating an Adapter ...................................................................3-8
Resetting Factory Defaults ......................................................... 3-9
SCSI Device Configuration ............................. ...... ...... .....................3-10
Scanning the SCSI Bus ............................................................3-15
Viewing SCSI Device Handshake ............................................3-16
Modifying Device Configuration ................................................3-17
Locating a Device .....................................................................3-20
Verifying a Device ....................................................................3-20
Performing a Low-Level Format of a Device ............................3-21
Chapter 4
Troubleshooting
Troubleshooting Guidelines ...............................................................4-1
Check the Installation Procedures ..............................................4-1
Verify Host Adapter Configuration Settings ................................4-1
Check Device Driver Compatibility .............................................4-2
Verify SCSI Device Configuration and Connectivity ...................4-2
Troubleshooting Startup ....................................................................4-3
Questions & Answers
Appendix A
Small Computer System Interface (SCSI)
What is a host adapter? .....................................................................A-1
What does SCSI stand for? ...............................................................A-1
What is the SCSI bus? ......................................................................A-2
What are the SCSI bus length limitations? ........................................A-2
What is a Daisy Chain Configuration? ...............................................A-3
What is a SCSI ID? ............................................................................A-3
What is termination? ..........................................................................A-3
What kinds of terminators are there? .........................................A-3
What are SCSI Cables and Connectors? ..........................................A-4
Appendix B
Mylex Customer Support
Technical Support...............................................................................B-1
Product Support Record ....................................................................B-2
viii FlashPoint™ LT BT-930 User’s Manual
Chapter 1
Introduction
The Mylex FlashPoint™ LT PCI Host Adapter is a single channel host adapter offering device driver support for major industry standard desktop operating systems. It is based on Mylex-designed ASIC technology. It provides high-performance interconnection between the Peripheral Component Interconnect (PCI) bus and up t o seven Small C omp ut er Sys t em Interface (SCSI) peripheral devices.
Green LED
Red LED
External SCSI Connector (SCSI 2)
Figure 1-1. The FlashPoint LT Host Adapter
Internal SCSI Connector
Mylex SCSI
ASIC
BIOS
LED
Connector
The FlashPoint adapter complies with PCI Specification Rev. 2.1, operating at the maximum PCI local bus rate of 133 MBytes/sec in 32-bit data burst mode. Mylex host adapters offer exceptionally high product reliability due to reduced component count and lower power consumption. Minimized command overhead results in faster command execution. The adapter BIOS supports disk drives, even those with greater than 8 GBytes capacity.
Manual No. 3000863 1-1

Configuration

Configuration
Plug and Play Operation. FlashPoint adapter configuration is handled by the PCI motherboard. Operating parameters can be adjusted using AutoSCSI, a menu-driven utility residing in the adapter’s Read Only Memory (ROM).

Features

The FlashPoint PCI host adapter has the following features:
• Fast data transfer rates
The FlashPoint supports standard data transfer rates including Fast SCSI-2 at 10 megabytes per second and Ultra SCSI rates at 20 megabytes per second.
• SCAM Support
The FlashPoint supports the SCSI-3 SCAM (SCSI Configured Automatically) ConLevels 1 and 2 protocols for SCSI ID assignment. SCAM devices do not require manual SCSI ID assignment. The FlashPoint adapter assigns a SCSI ID to the de vice as requir ed. See the owner’s manual for your peripheral devices to determine whether or not they support SCAM.
• SmartTerm
The FlashPoint has no onboard jumpers. With SmartTerm, the FlashPoint adapter determines the configuration of the daisy chained devices, and self-terminates as required. See the owner’s manual for your SCSI devices to determine how they support termination.
•SeqEngine
SeqEngine provides automated SCSI command processing which reduces SCSI command overhead by minimizing the need to interface with the host processor. This results in improved performance.
1-2 FlashPoint™ LT BT-930 User’s Manual
Introduction

Hardware Requirements

Your PCI computer needs:
• One available PCI b us master e xpansion slot for each FlashPoint being
installed
• A 3.5" floppy drive
• DC power for internal SCSI drives or AC power for external subsystems
You need the following cables:
• A 50-pin cable with a high-density connector to connect the FlashPoint adapter to external devices
• A 50-pin, flat ribbon cable to connect internal SCSI devices to the FlashPoint adapter (included with adapter kit)
• An optional cable to connect the drive activity LED on the host front panel to the FlashPoint adapter
Note
The device activity LED cable is usually supplied with the host system.
The peripherals you are attaching to the FlashPoint adapter should be SCSI-2 or SCSI-3 Common Command Set (CCS) compatible.
Manual No. 3000863 1-3

Software Requirements

Software Requirements
You may need the following software:
• Software for hard drive setup to perform partitioning and high-level formatting
• Operating system software for hard drives being installed
• Device drivers

Device Driver Needs

You may also find the drivers that you need in the Mylex SCSI Host Adapter Software Kit. This kit contains device drivers that support:
• Multiple FlashPoint host adapters
• Up to seven SCSI peripheral devices (hard drives, etc.) per adapter
• Connectivity to SCSI tape drives, magneto optical (MO) disk drives and CD-ROM drives and other devices
See the FlashPoint Software User’s Guide if you are installing Mylex drivers.

Supported Operating System/Driver Support

Mylex SCSI adapter driver support are available for the following operating systems:
• PC/MS DOS 5.0 and above
• IBM OS/2 2.1x and Warp
•Windows 95
•Windows 3.x
• Windows NT 3.5x
• NetWare 3.1x, NetWare 4.x and 4.1x
•Solaris
• SCO UNIX
• UNIXWare
• Banyan Vines
1-4 FlashPoint™ LT BT-930 User’s Manual
Introduction
PC-DOS, MS-DOS and Windows. Your host adapter’s onboard BIOS allows you to attach up to seven SCSI disk drives without additional software under PC or MS-DOS 5.0 and above. Earlier versions of DOS only allow support for up to two hard disk drives.
Mylex offers device drivers that support ASPI (Advanced SCSI Program Interface) for configurations where more hard drives are needed than your version of DOS can support. Mylex also offer s CDROM dri ver s for DOS and Windows.
If you are installi ng other types of d e vices un der DOS and W in do ws, s uch as a tape backup device or a scanner, you will need to install additional drivers that support the ASPI interface to operate those devices. Those drivers are usually available packaged with the device or from third party sources.
Note
You can obtain the latest Mylex driver updates from the Mylex Bulletin Board System (BBS) for host adapter products, via modem at 510-7 93-3491. (Up to
14.4K, N, 8, 1)
See the FlashPoint Software User’s Guide if you are installing Mylex drivers.
Manual No. 3000863 1-5

Reference Documents

Reference Documents
You should have the following documents on hand during installation:
• The installation and set-up guide for your computer
• The installation guide for your SCSI peripherals (e.g., hard drive, CD-ROM or tape drive)
• Operating system installation and user’s guide
FlashPoint Software User’s Guide or third-party device drivers (if applicable)

Specifications

Dimensions:
Electrical:
Operating Voltage 5±0.25V Operating Current .6A Max. Max. Ripple/Noise 100 mV and 100 mV
Environmental:
Temperature 0°C to 60°C (32°F to 128°F) Relative Humidity 10% to 95% non-condensing Altitude 0 to 10,000 ft. operating
Interface Connections:
SCSI Internal 50-pin double-row connector SCSI External 50-pin shielded SCSI connector To/From System PCI standard edge connector
MTBF:
5" x 3.2"
0 to 15,000 ft. nonoperating
90,000 hours
1-6 FlashPoint™ LT BT-930 User’s Manual
Chapter 2
Installation
This section details hardware installation. See Chapter 3 for information on using AutoSCSI to configure adapter operati ng parameters.

What’s Covered in This Section

1. Unpacking the adapter and preparing for installation
2. Installing your FlashP oint
3. Configuring and cabling internal SCSI devices
4. Configuring and cabling external SCSI devices
5. Powering up the system
6. Hard drive set up

Unpacking

Before handling the FlashPoint, take precautions to avoid damage from electrostatic discharge: either use a grounding strap, or, touch your a metal
part of your computer chassis to discharge static electricity before handling the board. Always hold the board b y the edg es, even after static electricity is
discharged.
1. Check that your shipment is complet e w ith cables, documentation and diskette.
2. Remove the board from its protective envelope.
3. Verify that no physical damage occurred during shipping by inspecting the board for bent pins, loose parts, broken traces, and chipped or broken connectors.
Manual No. 3000863 2-1

Installation Tools

Warran ty Information

If damage to the board has occurred, return it in the protective envelope and original packaging with this manu al to your Mylex board supplier. The shipping agent should also be notified if the unit has been damaged during shipment. The Mylex warranty conditions are given in the back of this manual.
Installation Tools
The following items may be needed to assist with installing the adapter into your system:
• Small screwdriver
• Host system hardware manuals and manuals for the peripherals being installed.

Setting the SCSI Device ID

Each SCSI device is assigned a unique SCSI ID ranging from 0 through 7. Most SCSI peripheral devices are shipped with a preassigned SCSI ID number. Your FlashPoint is , by default, SCSI ID 7.
If you need to change the SCSI ID for a peripheral device, refer to the instructions in its owner’s manual. A SCSI ID jumper or switch is usually located on the peripheral’s back panel.
T o change you r adapter SCSI ID use the V iew/Modify Adapter Configuration option on the AutoSCSI’s Adapter Configuration Menu (Chapter 3, “Adapter and Device Configuration”).
Note
FlashPoint LT allows the user the option of selecting the boot drive and specifying its SCSI ID through AutoSCSI. If the SCSI ID of the boot drive is set to zero then BIOS looks for the boot drive by scanning devices according to their SCSI ID, starting at SCSI ID 0. In this case, mak e sure that your bo ot device has the lowest SCSI ID.
2-2 FlashPoint™ LT BT-930 User’s Manual
Installation

SCAM Support

The FlashPoint adapter supports SCAM Levels 1 and 2. If your peripheral device supports SCAM, the FlashPoint adapter will determine an available SCSI ID and assign it to the device.
SCSI peripheral devices that do not support SCAM (legacy) are shipped with a preassigned SCSI ID number . You can change this ID if necessary . A SCSI ID switch is usually located on the back panel of such devices. It may be in the form of a jumper or a switch whose setting indicates the SCSI ID. If you need to change the SCSI ID for the other peripheral devices, refer to the instructions in the owners manual for the device.

Terminating SCSI Devices

The SCSI devices connected on the ends of the cable of a SCSI bus must have terminators installed or enabled. Terminators, which can be connected to either SCSI devices or SCSI cables, are required for reliable operation of the SCSI bus.
Note
Pass through cable t erminat ors may not prop erl y terminate the device. For greater reliability, Myle x recommends the use of active terminators for all devices.
If more than two SCSI devices are connected in a SCSI daisy chain, disable the termination on the middle device(s).
The FlashPoint is equipped with SmartTerm™ and does not require any physical configuration for termination. SmartTerm requires no user interaction and automatically enables or disables the FlashPoint termination depending on the configuration of the SCSI bus in the system.
Note
There are devices on the market, such as some pass through terminators and de v i ces with 26-pin DB connectors, that do not conform to SCSI specifications. With such devices on the cable, the SmartT er m log ic on th e FlashPoint LT board does not
Manual No. 3000863 2-3

Installing Your FlashPoint

work properly. To overcome this problem, the FlashPoint adapters provide an AutoSCSI option to disable onboard termination.
Installing Your FlashPoint

Step 1: Prepare the host system and the adapter

When you are ready to begin, power down the host system. Referring to your host system owner’s manual, remove the covers to open
the case to gain access to the motherboard and expansion slots as shown in Figure 2-1.
If the computer has been on, wait a few minutes until the power supply case has cooled down inside the computer. If the power supply case is cold, touch it to discharge any static electr icity t hat may be on your clothes or body.
Figure 2-1. Remove the Cover and Bracket
To install the adapter card, remove the mounting screw and the existing bracket from the rear panel behind the selected PCI slot.
2-4 FlashPoint™ LT BT-930 User’s Manual
Installation
Note
The FlashPoint adapter can only be installed in a busmaster slot. Refer to your syst em docum en tatio n to determine the correct slot for installation.

Step 2: Install the adapter

Press the FlashPoint adapter into the selected PCI slot (see Figure 2-2). Align the mounting bracket, and reinstall the mounting screw.
Figure 2-2. FlashPoint adapter Installation
m Caution
Make sure that the board is properly seated in the slot.

Step 3: Install internal devices and cables

Internal devices require a 50-pin flat ribbon cable. Use the ribbon cable included with the FlashPoint to install o ne or two internal devices. Install one end of the ribbon cable to the 50-pin double-row SCSI connector on the FlashPoint host adapter (see Figure 2-3).
Before plugging in the cable, check that the “” mark molded on the connector or the colored stripe on the cable (indicating the location of Pin 1) matches Pin 1 of the connector on the board.
Manual No. 3000863 2-5
Installing Your FlashPoint
Figure 2-3. Installing Internal Devices and Cables
When installing one internal device, connect it to the end of the cable and terminate the device. Consult the owners manual for information on how to terminate the device.
If a second internal device is to be included in the internal installation, terminate only the device at the end of the cable. If the default config uration for the device in the middle of the cable is terminated, consult the owner’s manual to find out how to disable termination.
Be sure each device has a unique SCSI ID assigned. See “Setting the SCSI Device ID” on page 2-2 in t his chapt er for mor e in formati on about assign ing SCSI IDs.

Install the LED Cable (Optional)

Insert the connector from the drive activity LED on the front panel of the host to the connector on the FlashPoint as shown in Figure 2-4. This connector is reversible and may be plugged into the connector in either direction. If your system has a two-pin LED drive acti vity connector, use the first two or the last two pins. The following diagram shows the connector pin-outs.
2-6 FlashPoint™ LT BT-930 User’s Manual
Pin 1 Pin 4
+5V Gnd Gnd +5V
Figure 2-4. Installing the Optional LED Cable

Step 4: Install external devices and cables

Installation
Figure 2-5. Installing External Devices and Cables
External devices are connected using a 50-pin cable with a high-density SCSI-2 connector.
Manual No. 3000863 2-7
Installing Your FlashPoint
Connect one end of the SCSI cable to the adapter’s SCSI connector and the other end to the SCSI device as shown in Figure 2-5. Devices are attached in a daisy chain configuration until a maximum is reached. The last device in the daisy chain must be terminated. All intermediate devices should not be terminated or should have termination disabled.
Be sure each SCSI device has a unique SCSI ID assigned. Refer to “Setting the SCSI Device ID” on page 2-2 below for more information about assigning SCSI IDs.

A Note about SCSI BUS T ermination

The FlashPoint adapter supports both internal and external devices. If more than two SCSI devices are connected in a SCSI daisy chain (the FlashPoint adapter card is considered one device in the chain), remove or disable the terminator resistor pack on the middle devices.
• When attaching internal devices only, the last device in the chain must be terminated. The FlashPoint adapter automatically terminates the other end of th e SCSI bus.
• When attaching external devices only, the last device in the chain must be terminated. The FlashPoint adapter automatically terminates the other end of th e SCSI bus.
• Both internal and external devices can be attached to the same FlashPoint adapter. The last device at each end of the SCSI bus (one internal end and one external end) must be terminated. (See Figure 2-
6.) The FlashPoint automatically disables its termination to ensure SCSI bus integrity.
2-8 FlashPoint™ LT BT-930 User’s Manual
Installation
Internal End of SCSI Bus
External End of SCSI Bus
SCSI Bus
Figure 2-6. SCSI Bus Ends
• Illegal Configuration (see Figure 2-7) Illegal configuration involves connecting the FlashPoint adapter in the
middle of a SCSI ribbon cable. The FlashPoint adapter must be connected at one end of the ribbon cable.
Figure 2-7. Illegal Cabling Configuration
Manual No. 3000863 2-9
Installing Your FlashPoint

Maximum SCSI BUS Lengths

The SCSI bus may not exceed the maximum lengths listed in Table 2-1. The limitations listed in this table are for 8-bit data path SCSI d evices. Wide SCSI (16-bit data path) is not supported by the FlashPoint LT host adapter. The total length of the SCSI bus is made up of all the cables that interconnect the FlashPoint to all the devices in the daisy chain configuration including the length of the internal ribbon cable, if it is used (see Figure 2-8). If the SCSI bus exceeds the recommended length, the SCSI devices may display unpredictable behavior.
Table 2-1. Maximum SCSI (8-bit) Bus Configuration Limits
SCSI Type Data Transfer Rate
(MB per second)
SCSI-2 5 or less 8 6 meters (19.7 feet) SCSI-2 10 8 3 meters (9.8 feet) Ultra SCSI 20 4 3 meters (9.8 feet) Ultra SCSI 20 8 1.5 meters (4.9 feet)
Maximum
Number of
Devices
Maximum
Cable Length
End
Measure SCSI Bus
Start
SCSI Bus
Figure 2-8. SCSI Bus Length Limitations
2-10 FlashPoint™ LT BT-930 User’s Manual
Installation

Step 5: Power up the System

Once the adapter is installed, power up the system. As the system powers on, the BIOS performs a self test. Any error conditions that arise from the self test are displayed on the start-up screen. Should you encounter any conditions that you can not resolve, contact Mylex Customer Service at the numbers and/or addresses listed in Appendix B of th is manual.

Step 6: Ver if y devices

The FlashPoint adapter comes with an o nboard configuration utility, AutoSCSI, which resides in Read Only Memory (ROM). AutoSCSI is a menu-driven utility for configuring Mylex SCSI host adapters. You can use AutoSCSI to set or change SCSI and BIOS-related configuration parameters. In addition to simplified configuration, AutoSCSI offers diagnostics. See Chapter 3, “Adapter and Device Configuration,” for information about how to use this program to verify the connected devices.

Step 7: Set up hard drives

Most off-the-shelf hard drives are preformatted. If this is not the case, or your drive requires a low-level format as indicated by error conditions, use the low-level format utility included with the onboard AutoSCSI utility described in “Performing a Low-Level Format of a Device” in Chapter 3 of this manual.
Once the hard drive is low-level formatted, you will need to create a partition (or multiple partitions) and high-level format the partition(s) to prepare your drive for operating system installation. Your operating system may incorporate these partitioning and high-level format functions as part of its installation or may offer them as separate utilities. For example, DOS provides FDISK and FORMAT in its utilities suite.

Step 8: Install device driver s

In addition, you may need to install device driver software if your operating system does not include the required drivers for your installation as discussed in Chapter 1.
Driver installation usually takes place as part of operating system installation. Refer to your operating system installation instructions and the FlashPoint Software User’s Guide for details.
Manual No. 3000863 2-11
Installing Your FlashPoint
2-12 FlashPoint™ LT BT-930 User’s Manual
Chapter 3
Adapter and Device
Configuration
Note
Host adapter configuration is optional. Under normal operating conditions, you probably won’t need to perform any adapter configuration. However, if you need to adjust the adapter’s configuration, the AutoSCSI utility provides fast and easy configuration capabilities.
The BIOS on the PCI motherboard automatically configures the following parameters at power-up:
• Adapter I/O Port Address (Base Address Registers)
• BIOS Address (ROM Base Address)
• Interrupt Channel (IRQ)
Use AutoSCSI to further configure the FlashPoint adapter to suit your operating environment.

Bringing Up AutoSCSI

AutoSCSI resides in Read Only Memory (ROM). AutoSCSI is a menu­driven utility for configuring FlashPoint adapters. In addition to this utilities simplified configuration, AutoSCSI offers disk utilities.
AutoSCSI is available when the system is first powered up and at every system reset. Press
When invoked, the AutoSCSI window appears showing a selection dialog box listing the FlashPoint host adapters that are installed in the system (see Figure 3-1).
Manual No. 3000863 3-1
Ctrl+B
at the prompt that follows the BIOS banner.

Adapter Configuration

Figure 3-1. AutoSCSI Adapter Selection
Note
When you exit AutoSCSI after making configuration changes, the system prompts yo u to reset your sys tem. The reboot allows changes to the configuration to become operational.
The Legend at the bottom of the screen show you what keys are enabled for the window.
Adapter Configuration
1. Highlight the adapter you want to configure. Use the arrow keys to move up and down the selection list when more than one adapter is installed in the system.
2. Press <Enter>. The configuration selection dialog box opens on the display.
3. Select Adapter Configuration and press <Enter>.
3-2 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Figure 3-2. Adapter Configuratio n Op tion s
The functions menu appears on the display. You can select from the following options:
View/Modify Configuration
option allows you to view or change
FlashPoint configuration settings.
Locate Adapter
option helps you locate a host adapter in a multiple adapter configuration. Selecting this options causes the LED on the selected adapter to blink.
Load Factory Defaul ts
resets the current host adapter configuration to
the factory default settings. (See Table 3-3 for a list of default settings.)
4. To view or change the host adapter configuration, highlight View/ Modify Configuration and press <Enter>.
The View/Modify Adapter Configuration Window (see Figure 3-3) allows you to examine and modify the configuration of your host adapter(s).
Manual No. 3000863 3-3
Adapter Configuration
Figure 3-3. View or Modify Device Configuration Window

Adapter Configuration Fields

The left side of the window contains a list of the adapter characteristics that cannot be modified. These information fields are described in Table 3-1.
Table 3-1. Configuration Field Descriptions
Option Description Model BIOS Version
BIOS Address
3-4 FlashPoint™ LT BT-930 User’s Manual
This field identifies the model of the Mylex host adapter. This field identifies the version of the FlashPoint BIOS. If this
field contains a “-” character, the current host adapter is under the control of another adapters BIOS.
This field displays the SCSI adapter BIOS starting address in host memory. In a PCI system, the BIOS is automatically sized and placed in the memory map. When multiple FlashPoint adapters are present, only one BIOS is active.
Adapter and Device Configuration
Table 3-1. Configuration Field Descriptions (Continu ed)
Option Description
Port Address
PCI Bus # PCI Device # SCSI Channel IRQ
Channel
Termination
This field shows the base address of the registers the host uses to communicate with the host adapter. Each board and each channel within the same host system must have a unique I/O port address to prevent hardware conflicts. On PCI adapters, the host system’s BIOS assigns the I/O port address during the boot sequence.
This field shows the PCI bus number. This field shows the PCI device number The channel on the FlashPoint LT that is being configured. This field shows the hardware interrupt line (IRQ) number that
the adapter uses to generate interrupts to the host. The adapter issues an interrupt whenever it requests attention from the host. On PCI adapters, the host system’s BIOS assigns the IRQ value.
This field indicates whether the adapter’s automatic SCSI termination, SmartTerm is turned on or not. SCSI devices are daisy-chained together and a terminator is required at each end of the chain. Should the selected adapter be at t he beginning or the end of the SCSI chain, this value must be set to AUTO. Termination is enabled/disabled automatically by the FlashPoint host adapter.
When there are multiple adapters, the adapter with the highest BIOS address controls the process of reading data from other adapters for configuration information.

Modifying Adapter Configuration

The list of options on the right side of the screen may be m odified To change a value for an option, do the following:
1. Highlight the desired parameter using the arrow keys and press the <Spacebar>.
2. For example, when you select the SCSI ID parameter and press the <Spacebar>, a popup menu listing possible values for this parameter appears. Use the arrow keys to choose a new value from the popup list
Manual No. 3000863 3-5
Adapter Configuration
(see Figure 3-4) and press the <Enter> key to accept the selected value.
3. For example, when you select the Parity Detection parameter, use the <Spacebar> to toggle the setting On or Off.
Figure 3-4. SCSI ID Selection Popup Menu
T a ble 3-2 lists the configurable fields and possible values for those fields. Values shown in
BOLD ITALIC TYPEFACE
indicate the default factory
setting.
3-6 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Table 3-2. Adapter Configur ati on Opti on Descrip tio ns
Option Value Description
Adapter SCSI ID 0-
0
Boot Hard Disk SCSI ID
CD-ROM Boot Supports ON
-7 The SCSI ID of the Boot Drive. If the value
OFF
Map Removal as Fixed ON
OFF
Floptical Support ON
OFF
BIOS Support for 2+ HDD
ON
OFF
7
Use this option if you need to change the adapter’s SCSI ID on the SCSI bus. This ID should remain unchanged, even where there are multiple SCSI adapters, unless the adapters are attached to a common SCSI bus cable.
is set to 0, then BIOS will boot from the first SCSI ID starting from 0, that is included in the BIOS scan.
This setting indicates whether a CD-ROM drive is supported as a boot drive.
If the setting for this parameter is set to (the default), removable drives (SyQuest or Bernoulli for example) will not be attached by the BIOS to a DOS drive at Boot time. If the parameter is set to drives will be attached to a DOS drive letter if media is present at Boot time.
When this option is set to ON, the BIOS registers and controls floptical devices. Turn this option software to control floptical devices.
When enabled, DOS 5.x or later supports two to eight devices without drivers.
ON
OFF
if you have application
OFF
, removable
INT 13h Extension
Manual No. 3000863 3-7
ON
OFF
For Windows 95 this parameter supports devices with capacities greater than 8 Gigabytes.
Adapter Configuration
Table 3-2. Adapter Configuration Option Descriptions (Continued)
Parity Detection
Power Saving Mode
SCAM Mode
Termination (LO)
ON
OFF
ON
OFF
OFF
Level 1 Level 2
AUTO
OFF
This setting allows you to enable or disable parity checking by the adapter on the SCSI bus. Disable parity checking if it is not supported by the SCSI device. Refer to the device manual for more information. Select ON to enable or OFF to disable parity checking. Press <Spacebar> to toggle between selections. There are 8 bits or 16 bits of data plus one or two bits of parity on a standard SCSI bus.
This setting allows you to enable the power saving mode feature.
This setting lets you turn off the SCAM mode feature or lets you set it to Level 1 or Level 2.
This setting allows you to enable/disable terminators automatically by FlashPoint’s SmartTerm logic or force them to OFF.
Press the <Esc> key to exit the display. If you make any configuration changes, AutoSCSI prompts you to confirm your changes.
4. When you select Yes to save your changes, these changes are stored in Electrically Erasable Programmable Read Only Memory (EEPROM) and are recalled upon system reset.
If you enter No, your changes are cancelled.

Locating an Adapter

You can use the Adapter Configuration menu to help you find a specific adapter in a multiple adapter configuration.
1. To locate an adapter within the computer enclosure, highlight Locate Adapter and press <Enter>. The locating message is displayed on the screen (see Figure 3-5) while the LED on the adapter blinks.
3-8 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Figure 3-5. Locating the Adapter
NO
2. When you have found the adapter, press any key to return to the Adapter Configuration menu.

Resetting Factory Defaults

You can reset the adapter parameters to the factory default settings.
1. Highlight Load Factory Default and press <Enter>. For a list of the settings see Table 3-3. Default values are shown in
TYPEFACE
.
BOLD ITALIC
Figure 3-6. Load Factory Default
2. Respond to the warn ing mess age sho wn in Fi gure 3-7. W hen you select Yes the default settings are loaded and the system reboots. The factory default settings take effect after the system reboot.
Manual No. 3000863 3-9

SCSI Device Configuration

Figure 3-7. Factory Defaults Warning Message
SCSI Device Configuration
To perform device configuration, do the following:
1. Start AutoSCSI, choose an adapter and press <Enter>.
Figure 3-8. SCSI Device Configu ration
2. Use the arrow keys to highlight SCSI Device Configuration and press <Enter>.
The Device Window opens on the display (see Figure 3-9). The SCSI Device window provides two major menu options:
3-10 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Scan SCSI Bus causes AutoSCSI to perform a SCSI inquiry scan of
the bus. When the scan completes, the device configuration window displays the name of the device found at each SCSI ID.
View SCSI Device Handshake displays the host adapter’s
handshake protocol to each device on the bus. The protocol can be changed in the SCSI device View/Modify Configuration window.
Figure 3-9. SCSI Device Window
The initial device window shows all the devices as unscanned. Select View SCSI Device Handshake before the devices are scanned to see a window like that shown in Figure 3-10.
Manual No. 3000863 3-11
SCSI Device Configuration
Figure 3-10. Unscanned Devices Display
3. Press <Esc> to return to the device list.
4. To view a table of switch settings for an unscanned device ID, use the arrow keys to highlight an unscanned d evice ID and press <E nter>. A list of switch settings for the selected device ID is displayed (see Figure 3-11).
3-12 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Wide Negotiation
: -
Figure 3-11. Switch Settings Window
See Table 3-3 for a list of the switch settings and their values. Default values are shown in
Option Value Description
SCSI ID 0-
Negotiated Rate
BOLD ITALIC TYPEFACE
.
Table 3-3. SCSI Device Configuration Parameter Settings
7
Async Sync 5 MB/s
Sync 10 MB/s
Sync 20 MB/s
Use this option if you need to change a SCAM device’s SCSI ID on the SCSI bus. The FlashPoint host adapter’s ID is set to 7 by default.
This is the transfer data rate that the host adapter will attempt to establish with the target device.
: If you experience a system hang
Note
condition or data corruption, lower the negotiated rate to attempt to remedy the problem. If you are connecting an Ultra SCSI device be sure to change the negotiated rate to 20 MB/s.
Manual No. 3000863 3-13
SCSI Device Configuration
Table 3-3. SCSI Device Configuration Parameter Settings (Continued)
Option Value Description
Disconnection
Wide Negotiation
Motor Spin-up ON
ON
OFF
ON
OFF
OFF
BIOS Scan
ON
OFF
Use this option to enable or disable SCSI disconnection for each target device. This option allows a SCSI device to disconnect itself when it is not ready for data transfer. When multiple devices are connected to the same SCSI bus, SCSI disconnection allows SCSI devices to perform seek operations in parallel and improves overall SCSI bus performance.
The FlashPoint LT does not support wide negotiation. (Displayed with grey highlight.)
This option allows you to identify the drives whose motor spin-up is sequentially controlled by BIOS at power-up. When the disk drive has a spin-up jumper enabled that selects Spin-up at Power­On or Spin-up with Start Unit command, this
ON
parameter must be set to Setting this parameter to sequentially issue a Start Unit command at power-up. this command.
OFF
prevents BIOS from issuing
.
ON
, allows BIOS to
Note: If the jumper on the device is enabled and this parameter is set to OFF, although the drive letter will be recognized the device will not spin up.
This feature is also useful when you want to exclude a removable device from BIOS INT 13h support. You must install the DOS ASPI driver to support any device that is selected to be ignored by the BIOS scan. When will identify and register the device at the specified SCSI ID.
ON
, BIOS
Note: If this device is the boot device, then this option should be set to on.
3-14 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
To change the configuration parameters, do the following:
1. Use the arrow ke ys to high light a conf igur ation parame ter and press th e <Spacebar>. Configuration parameters with multiple value choices display a selection dialog box. Co nfi guration paramet ers with ON/OFF vales toggle.
2. For example, use the arrow keys to highlight Ne gotiated Rate and press the <Spacebar> to display the selection dialog box. Use the arrow keys to highlight the desired selection and press <Enter> to accept the selection.
3. For example, use the arrow keys to select the Disconnection parameter and press the <Spacebar> to toggle the value. Press <Enter> to accept the value.
4. When you have comp lete d changi ng the configuration parameter settings, press <Esc> to return to the SCSI Device window.

Scanning the SCSI Bus

Selecting the Scan SCSI Bus option causes AutoSCSI to perform a SCSI inquiry scan of the bus. To perform this scan operation, do the following:
1. Use the arrow keys to highlight Scan S CSI Bus and press <Enter>. The Scanning message appears on the display (see Figure 3-12).
Figure 3-12. SCSI Bus Scanning Display
2. When the scan is complete, the SCSI Device window updates to show the result of the SCSI bus scan (see Figure 3-13).
Manual No. 3000863 3-15
SCSI Device Configuration
Figure 3-13. Scanned Bus Display

Viewing SCSI Device Handshake

To view the SCSI device handshake settings, do the followin g:
1. Use the arrow keys to highlight Vi ew SCSI Device Handshak e and press <Enter>.
2. The SCSI Device Handshake window opens (see Figure 3-14). The transfer rate initially requested for the device and the actual transfer rate of the scanned device are listed in this window. Notice that the requested and the actual transfer rates may be different. If during the transfer rate negotiation, the device is found to be incompatible with the requested transfer rate, an acceptable rate is negotiated for the device.
3-16 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
Figure 3-14. SCSI Device Handshake Window
3. Press <Esc> to exit the window and return to the SCSI Device window.

Modifying Device Configuration

To make adjustments to the device configuration, do the following:
1. Use the arrow keys to highlight the device you wish to modify and press the <Spacebar>. The Device Configuration menu appear as shown in Figure 3-15.
Manual No. 3000863 3-17
SCSI Device Configuration
Figure 3-15. Device Configuration Men u
2. Highlight View/Modify Configuration and press <Enter>. The View/ Modify Device Configuration window appears (see Figure 3-16).
Wide Negotiation
: -
Figure 3-16. View/Modify Device Configuration Window
3-18 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
The left side of the screen shows the static characteristics of the selected device. These characteristics can not be modified. See Table 3-4 for a brief description of these parameters. Refer to the owner’s manual of your device for further information about the contents of this display.
Table 3-4. SCSI Device Static Parameters
Parameters Description
Vendor ID The name of the device manufacturer. Product ID The device’s model name. Firmware Version The device’s firmware version number. ANSI Version The SCSI level of the device. Synchronous Mode Indicates if synchronous mode is supported by the device. Wide Negotiation Indicates if wide negotiation is supported by the device. Command Queue Indicates if command queue is supported by the device. Device Type The type of device. Capacity (MB) The number of megabytes of storage in the device. Sector Sz (Bytes) The sector size of the device in bytes. SCAM Indicated if SCAM is supported by the device. Transfer Rate The data transfer rate of the device shown in MB/sec.
3. Use the <Page up> and <P age do wn > k e ys to change the display to the other SCSI devices on the SCSI bus.
The right side of the screen sho ws the de vices confi guration paramet ers that can be modified. See Table 3-3 for a list of the parameters and their values. Default values are shown in
BOLD ITALIC TYPEFACE
.
To change the configuration parameters, do the following:
1. Use the arrow keys to highlight a parameter and press the <Spacebar>. Parameters that can be toggled ON and OFF change when selected.
2. SCSI ID and Negotiated Rates have selectable values. Highlight the
Manual No. 3000863 3-19
SCSI Device Configuration
desired entry and press the <Spacebar>. A popup menu appears listing the selectable values. Use the arrow keys to highlight the desired value and press <Enter> to accept the highlighted value.
3. When you have completed changing the parameters, press <Esc> to return to the SCSI Device window.
4. When you have comp lete d viewing and modifying dev ice configuration, press <Esc> to return to the Device Co nfiguration menu.

Locating a Device

You can use the Device Configuration Menu to help you find a specific device within your configuration.
1. To locate a device, highlight Locate Device and press <Enter>. The locating message is displayed (see Figure 3-17) while the LED o n the device blinks.
Figure 3-17. Locating the Device
2. When you have fou nd t he device, press any key t o return to the De vice Configuration menu.

Verifying a Device

The Verify option scans the media of a selected device. Use this option to verify that your hard drive is operable. To verify the format of a SCSI disk device, do the following:
1. Highlight Verify and press <Enter>. The verification confirmation dialog box (Figure 3-18) appears.
Figure 3-18. Verif yin g the De vice
3-20 FlashPoint™ LT BT-930 User’s Manual
Adapter and Device Configuration
2. Select Continue to perform the device verification operation. Select Cancel to cancel the operation and return to the Device Configuration
menu.

Performing a Low-Level Format of a Device

You can perform a low-level f ormat of a de vice usin g the For mat option from the Device Configuration Menu.
1. Highlight Format and press <Enter>. The format confirmation dialog box appears (Figure 3-19).
Figure 3-19. Device Formatting Confirmation
2. Select Continue to perform the formatting operation. Select Cancel to cancel the operation and return to the Device Configuration menu.
WARNING
,
The device formatting operation erases any information that may be stored on the disk drive. Do not confirm this operation if there is any data on the device that you do not wish to erase. Before formatting, make sure that all necessary data is backed up.
If you make any configuration changes before you leave the Device Configuration window, AutoSCSI prompts you to confirm your changes.
When you select Yes, any configuration changes you may have made are stored in the serial EEPROM. If you enter No, your changes are cancelled.
Manual No. 3000863 3-21
SCSI Device Configuration
3-22 FlashPoint™ LT BT-930 User’s Manual
Chapter 4
Troubleshooting

Troubleshooting Guidelines

If you experience a problem with adapter operation when all the installation steps are completed, refer to the following guidelines.

Check the Installation Procedures

• Be sure all connectors are firmly seated.
• Check the orientation of the SCSI cable. Be sure that Pin 1 o n the cable matches Pin 1 on the adapter/SCSI device connector.
• Check that the adapter and attached devices have unique SCSI IDs.
• Be sure that the SCSI ID for the boot hard drive is the same as the ones in the AutoSCSI option. If the ID 0 (zero) is specified in that option, BIOS determines the boot drive by scanning SCSI devices starting from ID 0. If the boot drive number is higher than the other drive, change it to a lower value.
• Be sure that you’ve followed SCSI termination rules.
• Check that you have correctly set the CMOS hard drive option to not installed in your system SETUP file.

Verify Host Adapter Configuration Settings

Note
Although IRQ and BIOS Addresses are autom atically configured in a PCI system, differences in PCI bus implementation may result in conflicts among adapters from more than one manufacturer.
Check the adapter’s IRQ setting. Verify that each installed card has a unique IRQ value. There may be a conflict with ISA (non-PCI) adapters. If this occurs, you must change the non-PCI adapter’s IRQ setting.
Manual No. 3000863 4-1
Troubleshooting Guidelines
For example, you have installed the ASPI DOS driver in the CONFIG.SYS file and are attempting to boot from a SCSI disk drive. The system begins the boot sequence, the b anner is displayed , attached SCSI devices are recognized and posted on the display. A message is then displayed indicating that th e SCSI DOS driver is being installed, however, the system appears to suspend operation with no further boot activity. In this sequence of operation, BIOS does not require IRQ support, so it proceeds without problem. The DOS driver requires the IRQ and quickly stops operation after being installed because of a possible IRQ conflict.
Verify AutoSCSI configuration. If you have changed adapter SCSI-
or BIOS-related parameters via AutoSCSI, use the Load Factory Default option on the AutoSCSI Adapter Configur atio n Menu to return the board to factory-set defaults. Check that you have selected operating parameters that do not conflict with those of other installed adapters before re-entering your changes.

Check Device Driver Compatibi lity

• Check that you have installed no more devices than your operating system or driver can handle. For example, pre-DOS 5.0 versions of DOS can handle only two hard drives. To handle more devices, you must install additional drivers.
• Under DOS, be sure that you ha ve installed dri v ers appropr iate for each installed device. For example, you cannot operate a CDROM device without installing a CDROM driver for it. Mylex provides a DOS CDROM driver. Refer to driver installation for further details.
• Be sure you have compatible device driver software installed.

Verify SCSI Device Configuration and Connectivity

Verify that the SCSI cabling is correctly attached and that the adapter can communicate with a selected device by performing the following:
Check the adapter’s ability to communicate with attached devices. Invoke AutoSCSI, and select the SCAN SCSI Bus option on the SCSI Device list. This option will scan the SCSI bus displaying the message shown in Figure 4-1. When the scan operation is complete, it registers all the SCSI devices and displays the device information. If the device
4-2 FlashPoint™ LT BT-930 User’s Manual
Troubleshooting
information is displayed without error, then the adapter is properly communicating with the SCSI devices.
Figure 4-1. Device Scanning Dialog Box
If an attached SCSI device is not recognized, verify that each device has a unique SCSI ID. The host adapter is set to SCSI ID 7 by default.
Disable Fast Transfer Rate. Some SCSI de vi ces may not be capable of negotiating a data transfer rate of 20 /10 MBytes/sec. If a d evice cannot support the higher rate, it is supposed to reject that value and propose a lesser value it can support. Some older SCSI devices when requested to negotiate at 20/10 MBytes/sec will halt operation. Try selecting a lower negotiating data transfer rate or set the requested transfer rate to Async in the View/Modify Device Configuration menu.
Motor Spin -U p. Some SCSI disk devices may not be configured to spin-up on power-on or upon reset. This will cause an error if the operating system attempts to access this device. When this occurs, enable the Motor Spin-Up option in the AutoSCSI View/Modify Device Configuration menu. If this option is enabled and the selected device does not require this option to be enabled, the device will probably ignore it.
Power. Be sure that all external SCSI devices a re secur ely co nn ected to a power source.

Troubleshooting Startup

At system startup, the FlashPoint adapter performs a self-test, runs tests on the SCSI bus, and performs SCAM on the SCSI bus devices. As these operations are executing, screen messages appear briefly. When all the operations are complete, a BIOS installation completion message is displayed and your system should continue to boot. If the startup operations do not complete successfully, an error message may be displayed. There are also conditions under which an operation will not complete successfully and the system will hang before an error message can be displayed. System hang instances and error messages are shown below. Where possible, problem resolution procedures are included.
Manual No. 3000863 4-3
Troubleshooting Startup
NO BIOS BANNER IS DISPLAYED
The system does not find the adapter. Make sure the adapter is properly installed in a busmaster slot.
SCANNING BUS...CARD XXX, SLOT X, BUS:XXX PORT XXXXX
If the system hangs with this message, the bus scanning operation did not complete successfully. Check the following:
• Verify all the cables and connectors are firmly seated and properly installed.
• Verify there are no reversed cable connections.
• Verify the FlashPoint adapter is installed in a busmaster slot.
• Verify all the devices, including the FlashPoint adapter, have unique SCSI IDs.
BIOS NOT INITIALIZED. NO SCSI TARGETS RESPONDED.
This message indicates that no SCSI devices have been detected:
• Verify the SCSI devices are properly cabled and connected.
• Verify all external devices are powered on.
• Verify all internal devices are connected to the power supply.
ENTERING CARD DIAGS/INIT, CARD:00 ERROR: ADAPTER CONFIGURATION FAILURE. DIAGS: SCSI BUS FAILURE, CHECK CABLES!
This message indicates that the SCSI bus has failed the diagnostic test. Test failure is often due to improper connections or bad cables. Do the following:
• Turn the system off and then on again. This action retries the diagnostic test.
• Verify all cables and connectors are properly installed.
• Verify there are no reversed cable connections.
ENTERING CARD DIAGS/INIT, CARD:00 ENTERING SCSI BUS RESET PROTOCOL. ENTERING SCSI BUS INTEGRITY TEST. ENTERING SCAM SELECTION.
If the system hangs at this point in the diagnosti c tests, ch eck the following:
• There may be a SCSI ID conflict, verify that each SCSI device has a
4-4 FlashPoint™ LT BT-930 User’s Manual
Troubleshooting
unique SCSI ID.
• The SCSI bus may be improperly terminated. Verify that the bus is terminated properly.
BIOS INITIALIZATION SUCCESSFUL SCSI 0, XXXXX SCSI 1, XXXXX
If the system hangs with this message on the display, there may be a SCSI bus termination problem.
• Verify that the SCSI bus is terminated properly.
ENTERING CARD DIAGS/INIT CARD=OO DIAGS ERROR IN DIAGNOSTIC TESTING. DIAGS:S/G RAM FAILURE LOW->ADDRESS=XXXX
ACTUAL=XXXX EXPECTED=XXXX S/G RAM FAILURE HI->ADDRESS=XXXX ACTUAL=XXXX EXPECTED=XXXX
This message indicates a RAM diagnostic failure. Problems may include the following:
• The adapter card is bad. Stop and restart the system to retry the
operation.
• The adapter card is not compatible with the system. Ch eck to see if
your system uses the VIA Chipset. If it does, revision CF or earlier is not compatible with the adapter. CG or later is compatible with the adapter.
• The BIOS is not PCI compliant.
ERROR: NON-PCI COMPLIANT SYSTEM BIOS, PLEASE UPGRADE.
This is not an adapter-related problem. Call the motherboard manufacturer for information on upgrading your system BIOS.
Manual No. 3000863 4-5
Troubleshooting Startup
4-6 FlashPoint™ LT BT-930 User’s Manual

Questions & Answers

Q. Why does the “NO ROM BASIC” message appear when booting up?
A. The DOS partition may not be activated, run the MS DOS FDISK utility and set the partition active. Refer to your MS DOS reference manual for specific instructions on activating a DOS partition using the FDISK command.
Q. Why is the message “Missing Operating System” displayed during boot, but the hard drive is still seen by the controller?
A. Check for the active partition. High level format the partition with the “format C:/s” option. Note, this will erase any data currently on yo ur hard drive. If the drive was previously used on another controller, you may need to perform a low-level format and then prepare the drive with DOS Fdisk and Format utilities. If the mapping mode has been changed since the last hard disk partitioning, perform another Fdisk an d Format.
Q. My system displays a “Har d Disk F ailure” messa ge during boot up, what can I do to correct it?
A. Check all cables and drive jumpers. Make sure the drive for the C: drive is “Type 0" or “Not Installed” in System CMOS if no IDE is installed.
Q. When my system boots up, the banner shows 6 drives, but I only have 1 drive. What is wrong?
A. Check that the drive is not the same SCSI ID as the SCSI controller, which defaults to ID 7. Make sure your drive is set to SCSI ID 0.
Manual No. 3000863 Q&A-1
Q. How can I use a CDROM drive wi th Mylex contr oller card in MS-DOS?
A. In DOS, make sure the SCSI ID for the CD-ROM is higher than the disk SCSI ID. Connect the CD-ROM in the SCSI chain so that it is properly terminated. Then add these two lines to your CONFIG.SYS.
device=c:\path\flashpt.sys /d device=c:\path\btcd-rom.sys /d:mscd001
Add this line in your AUTOEXEC.BAT:
c:\dos\mscdex.exe /d:mscd001
Q. When I load the FLASHPT.SYS driver in the DOS CONFIG.SYS, the system hangs.
A. Do followings:
1. Make sure the IRQ settings are configured properly. In the system CMOS under PCI option, there is an IRQ setting. Make sure an IRQ is being assigned to the Mylex slot.
2. Try a different IRQ. For example, i f you are using IRQ 12, try IRQ 11. Make note of the first requirement above, make sure it applies when you try a different IRQ.
3. Get another copy of the latest versio n of FLASHPT.SYS and try it. The original file may be corrupted. Copies of this file can be obtained in our BBS, FTP site, or WWW page.
Q. Why I am getting slow transfer times with my new FAST SCSI-2 hard drives .
A. Make sure the drive is jumpered FAST SCSI-2 and active termination. Also check that the controller has both Synchronous Negotiation and Fast Data Transfer enabled.
Q&A-2 FlashPoint™ LT BT-930 User’s Manual
Q. I am connecting a removable drive to the Mylex adapter in DOS. What device drivers do I need to load?
A. In DOS, you need to load DOS Manager drivers in CONFIG.SYS as follows:
device=c:\path\flashpt.sys /d device=c:\path\btmdisk.sys
After that run BTFDISK program to create the partition on the drive connected to second card and use the DOS FORMAT command to format the drive.
Q. I am connec ting a SCSI tape drive to the Mylex adapter. What device driver do I need to load?
A. You need to load DOS Manager driver in CONFIG.SYS as follows:
device=c:\path\flashpt.sys /d
You also need tape backup software.
Q. I have a large capacity (more than 1GB) drive. When I run FDISK, it recognizes only 1 GB capacity. What is the problem?
A. Make sure you enable the DOS > 1 GB switch on the adapter. If you plan to run NetWare, leave this option off and create your DOS partition in the first 1G.
Q. I have a floppy tape backup and it runs very slowly with the Mylex SCSI adapter. What should I do?
A. When you load DOS manager, use the “/n04” switch to reduce bus on time from default 11us to 4us.
Manual No. 3000863 Q&A-3
Q. Why does my system lock up on bootup after connecting to an external SCSI device?
A. Double check for proper SCSI bus termination and check connections and cabling.
Q. I added a new SCSI device to one of the Model C SCSI host adapter s. Either it is not seen or the system hangs when the host adapter BIOS tries to scan it. Do I have the proper SCSI bus termination?
A. This problem occurs mainly because the new device is not SCSI II FAST. You need to change the Enable Fast Transfer option to No in the AutoSCSI Configuration Menu. Disable the Enable Synchronous Negotiation option too, if it is not supported by the device.
Q&A-4 FlashPoint™ LT BT-930 User’s Manual
Appendix A
Small Computer System
Interface (SCSI)
This appendix describes the Small Computer System Interface terms. It is provided to help you understand the concepts related to SCSI.

What is a host adapter?

A SCSI host adapter is a printed circuit card that provides a SCSI bus interface to the SCSI devices installed in a computer system. The FlashPoint host adapter has both internal and external SCSI connectors supporting both internal and external SCSI peripheral devices.

What does SCSI stand for?

SCSI stands for Small Computer System Interface. SCSI is a computer bus interface standard that allows a variety of computer peripheral devices such as disk drives, CD-ROM drives and tape drives to interface to a host computer. SCSI-1, SCSI-2 and SCSI-3 are different version of the SCSI protocol standard.
• SCSI-1 is the original standard that defines the SCSI interface. This standard includes the definition of a command set, the electrical characteristics of the SCSI bus, and a 5 megabytes per second data transfer rate.
• SCSI-2 adds features to the standard including, SCSI linking, command queueing, and support for additional SCSI peripheral devices. The SCSI-2 standard also includes the following:
• Fast SCSI is a SCSI data transfer standard that allows up to 10
megabytes per second data transfer on the SCSI bus.
• Wide SCSI provides data transfer at 16-bits for faster data
throughput. Up to 20 megabytes per seco nd is suppo rted on F as t and Wide SCSI host adapters.
Manual No. 3000863 A-1

What is the SCSI bus?

• SCSI-3 adds more features including Ultra SCSI, SCAM, optional P­cable, the Wide SCSI bus specification that defines an extended number of devices, support for fiber channel hardware, and a serial channel interface. It also allows transfer rates of 20 megabytes per second.
What is the SCSI bus?
A SCSI bus is one or more SCSI peripheral devices and a host adapter connected together by cables in a daisy chain configuration. The SCSI bus may include both internal and external devices on one bus.
• A Narrow SCSI bus may have up to eight devices. The host adapter counts as one device.
• Wide SCSI supports up to 16 devices. Note, however, that Wide SCSI is not supported by the FlashPoint LT host adapter.

What are the SCSI bus length limitations?

The SCSI bus maximum length is determined by the data transfer rate and the number of devices in the configuration. Table A-1 lists the data transfer rates, the maximum number of devices and the maximum allowable cable lengths for each.
Table A-1. Maximum SCSI Bus Configuration Limits (Narrow Only)
SCSI Type Data Transfer Rate
(in megabytes per
second)
SCSI-2 5 or less 8 6 meters (19.7 feet) SCSI-2 10 8 3 meters (9.8 feet) Ultra SCSI 20 4 3 meters (9.8 feet) Ultra SCSI 20 8 1.5 meters (4.9 feet)
Maximum
Number of
Devices
Maximum
Cable Length
Remember when measuring the length of the SCSI bus, you must include all the connecting cables including the internal cable if it is used to connect internal devices.
A-2 FlashPoint™ LT BT-930 User’s Manual
Small Computer System Interface (SCSI)

What is a Daisy Chain Configuration?

A daisy chain is where the bus is created by attaching the first device in the chain to the second device and the second device to the third device and so on until all the devices are chained together.

What is a SCSI ID?

A SCSI ID is a unique identifying number ranging from 0 to 7. (0-15 for Wide SCSI) This number is assigned to a SCSI device on the SCSI bus. The SCSI ID identifies the device and determ ines the priority of the de vice on the SCSI bus. The priority of the de v i ce on th e bus is important when more than one device attempts to access the bus at the same time. The higher the SCSI ID number the higher the priority of the device during bus access. The FlashPoint adapter is preassigned SCSI ID 7, giving it the highest SCSI bus priority.

What is termination?

T ermination is an electrical characteristic of a SCSI bus. In order for devices to transmit and receive data and signals reliably over the SCSI bus, the bus must be properly terminated at both ends.
Devices can be terminated in a variety of way:
• The FlashPoint adapter supports SmartTerm. This means that the FlashPoint adapter determines where it is located in the daisy chain and either enables or disables its own termination as required.
• Peripheral devices can be terminated using a sev eral dif feren t methods. Some require termination plugs, thumb wheel setting, and/or DIP switches. Refer to the documentation that accompanies the device to determine what the termination method is. If the device occupies either end of the daisy chain, it must be terminated properly in order for the SCSI bus to function properly.

What kinds of terminators are there?

For external de vices there are SCSI-1 and SCSI-2 type terminators. Standard SCSI-1 terminators fit into Standard SCSI-1 connector receptacles. SCSI-2 terminators fit into SCSI-2 receptacles.
Manual No. 3000863 A-3

What are SCSI Cables and Connectors?

Internal devices may be terminated using cable terminators, however it is more likely that an internal device will use some sort of other method of termination like a resistor pack or a jumper.
When determining how to terminate a de v i ce, e xam ine the device and check on the manufacturers suggested termination method as described in the product documentation.
The last device in the chain must be terminated. The terminator may be a SCSI-2 type terminator or Standard SCSI-1 (Centronics).
The cable to the device may need a SCSI-2 type plug or a Standard SCSI (Centronics) type plug.
It is recommended that you use active terminators rather than passive termination.
What are SCSI Cables and Connectors?
There are several types of SCSI cables and connectors. Cables are used between the devices in a SCSI bus to create the electrical
pathway that connects the devices to the host adapter. The FlashPoint LT adapter provides for both internal and external device attachment.
Internal Connections. The FlashPoint LT adapter’s internal connector is a standard 50-pin internal SCSI connector that provides attachment for the 24­inch ribbon cable with two additional de vice connectors. T his ribbon cable is provided with the adapter. You can connect two internal devices to the adapter using this cable. Remember when using this cable to connect internal devices to the FlashPoint adapter, the last device on the cable must be terminated.
External Connections. The FlashPoint LT adapter’s external connector is a SCSI-2 50-pin connector. In order to correctly cable devices, you must examine each device to determine what type of connectors need to be accommodated.
For example, if the peripheral device you want to attach to the FlashPoint adapter has standard SCSI 50-pin (Centronics) connectors, you will need to purchase an adapter cable that has a SCSI-2 connector on one end (to attach to the FlashPoint adapter external connector) and a SCSI 50-pin (Centronics) connector on the other end to attach to the adapter.
A-4 FlashPoint™ LT BT-930 User’s Manual
Small Computer System Interface (SCSI)
Each device needs to be examined to determine what type of connector is required. SCSI cables come in a variety of connector combinations so that the SCSI bus may be made up of a combination of device types with cable adapting for the differences between devices.
Manual No. 3000863 A-5
What are SCSI Cables and Connectors?
A-6 FlashPoint™ LT BT-930 User’s Manual
Appendix B
Mylex Customer Support
Mylex provides a number of services for customer convenience. These services include the following:
• You can reach Mylex’s Technical Support at 510-608-2400, Monday through Friday, from 6:00 a.m. to 6:00 p.m. Pacific Time. Before you call, please complete the Product Support Record on the back of this page.
• Mylex’s Technical Support Bulletin Board System (BBS) is available 24 hours a day, seven days a week. It provides information on software updates and new releases, technical bulletins, and other information.
You can reach the BBS at 510-793-3491. For access, all you need is a modem and communicati o ns s oftware of your choi ce. S et you r modem to 14.4 k baud, 8 data bits, 1 s top bit and no parity. Once connected, log on with your name and a password of your choosing.
FAX requests will be answered within 24 hours upon receipt at Mylex. Send your FAX requests to 510-745-7715. Please include a completed Product Support Record (on the back of this page).
E-Mail Addresses:
Internet: support@mylex.com FTP Site: ftp.mylex.com WWW Home Page: http://www.mylex.com
US Mail: Mylex Corporation 34551 Ardenwood Blvd. Fremont, CA 94555-3607
• To order Mylex software or additional manuals, call 510-608-240 0.
Manual No. 3000863 B-1

Product Support Record

Product Support Record
The information on this page should be compiled and provided to your supplier in writing to obtain technical support assistance. This will enable your supplier to respond more rapidly and more appropriately to your problem.

Mylex Product:

Mylex Product No: _______________________________________________ Serial Number: _________________ ___________________________ ______ Date of Purchase: _____________ _____________ ______________________ Firmware Version Number:__________ ___________________________ ____ BIOS Version Number: ___________ _____________ ____________________

Purchased From:

Company: ______________________________________________________ Address:________________________________________________________

Purchased By:

Name/Title: _____________________________________________________ Company: ______________________________________________________ Address: _______________________________________________________
_______________________________________________________________ Telephone #: ____________________________________________________ Fax #: _________________________________________________________

About System Hardware Configuration:

System Manufactur er:_____________________________________________ System Model and Speed:__________________________________________
_______________________________________________________________ System BIOS Manufacturer: _________ ___________________________ ____ Memory in System:_______________________________________________ Hard Drives on System: ________________________________ ___________

About System Software Configuration:

Operating System/Version: _________________________________________ Application Pr ogram/Version:_______________________________________

Detailed Description of Problem:

_____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________
B-2 FlashPoint™ LT BT-930 User’s Manual

Mylex Warranty - Customer Policy

Thank you for pu rchasing this Mylex product fo r your comput er system. I n addition to this high-qu ality produc t, your purchase entitles you to the warranty coverage set forth herein. In order to provide this warranty coverage, and to indicate yo ur ac cept ance of thi s warr an ty, we must have the att ache d Warranty Registrat ion Ca rd comp le ted and returned to us within 15 days of your pu rch ase. Also, in ord er for us to pr ovide you t he high est level of service, we must know where you purchased your MYLEX product.
Three Y ear Limited Warranty
If at any time dur in g the th irt y six mon th pe ri od imme di atel y f ollowing the date of ori gi nal pu rch as e of the MYLEX product enclosed herewith (the “PRODUCT”) you discover one or mo re defects in the material or workma nship, MYLEX will repair, or at MYLEX’s sole option, replace the PRODUCT. If the PRODUCT fails to operate at any time within seven days after the date of its original purchase, it will be replaced by MYLEX. Such repair or replace­ment will be your sole remedy against MYLEX, and MYLEX ’s only liabi li ty to you, for any failure or malfunction of the PRODUCT. The warranty set forth in this paragraph will be void if:
1. The PRODUCT has been installed in an improper manner or in an improper operating environment.
2. The PRODUCT has been modified or repaired by any party other than MYLEX or a MY LE X fact ory authorized service center.
3. The PRODUCT has been damaged.
Some MYLEX products will have a Warranty Expiration Date lab el affixed to the product itsel f. When pre sen t, the warranty period will extend through the last day of the month indicated.
This warranty will not appl y to, and MYLEX provides no warran ty for, any BIOS, software, ROM-based firmware, or any other PRODUCT developed or manufactured by any third party, whether included with this PRODUCT or not. Such warranty or warranties as are provided by t hird parties, to the exten t permitted thereby, shall be made available, and are hereby assigned, by MYLEX to the purchaser of this PRODUCT.
If MYLEX issues a revision to the BIOS, firmware or software included with this PRODUCT within 30 days of your purchase, MYLEX will replace such firmware at no charge except handling fees.
Out of Warranty Service
Mylex products which are inelig ible for warran ty service may be servi ced by MYLEX according t o our standard price list, as modified f rom time to ti me. A current copy of the standa rd price list i s available from the Technical Support Department.
Limitation of MYLEX Liability
MYLEX’s liability arising from the sale, use and disposition of this PRODUCT shall in no event exceed the amount paid to MYLEX for this PRODUCT. MYLEX assumes no liability for damages arising from the use or failure of any MYLEX product. The WARRANY DESCRIBED ABOVE CONSTITUTES THE ONLY WARRANY MADE BY MYLEX. MYLEX EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND WHATSOEVER, WHETHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANT­ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY EXCLUDED. IN NO EVENT WILL MYLEX BE LIABLE FOR INCIDENTAL, SPECIAL OR CONSEQUEN­TIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOSS OF DATA, USE, OR INCOME), EVEN IF ADVISED OF SUCH DAMAGES IN ADVANCE. Your sole remedies shall be as provided herein.
P/N: 772058-03 6-98 Printed in U.S.A.
Returned Merchandise Procedures
If you suspect that there is a defect in the ma terial or workmanship o f this PRODUCT, you should contact the per­son or company from which you purc hased it. That person or company may be able to solve the problem and if not, will be able to contact us for t ec hni c al assist ance or repair.
If it is determined that the PRODUCT must be returned to MYLEX for repair or re placement, contact MYLEX’s Technical Support Department at 510-608-2 400 before it is returned. Each retur ned item must have a separate Return Merchandise Authorization (RMA) number, provided by MYLEX.
The following rules apply to all returned items:
1. The PRODUCT must be returned either in its origin al packagin g or in othe r packagi ng which is appropria te for the PRODUCT and the manner of shipment, and the RMA number must be displayed prominently on the outside of each such package.
2. If a PRODUCT is determined to be i neligi ble for warra nty service, t he c ustomer will b e no tified before any fur ­ther action is taken with the PRODUCT.
3. MYLEX will not be responsible for any loss or damage to property shipped with the RMA PRODUCT not origi­nally sold by MYLEX (e.g., co processor chips, periphera l b oa rds, memory modules, enclosures, power supplies, or any other accessories or atta ched items).
4. Any item returned to MYLEX wit hout a valid RMA number will be returne d to t he shipper. Products shipped to MYLE X must be shipped or mailed at the shipper’s risk, freight prepaid, to the address bel ow.
Mylex Corporation 34551 Ardenwood Blvd.
Fremont, California U.S.A.
94555-3607
Mylex will pay for return freight via suc h ca rrier as MYLEX shall deem approp ria te .
Technical Support
Technical support, to assist you in re solvin g probl ems with M YLE X prod ucts, is now available throu gh M YLEX’s Technical Support Department. In the U.S.A. , the Technical Support Department can be reac hed by telephone at (510) 608-2400 or by FAX at (510) 745-7715. Current hours of opera tion, which are subject to change, are from 6:00 a.m. to 6:00 p.m. Pacific Time, Mondays through Fridays, excluding U.S.A. national holidays.
Included with the shipment of mo st MYLEX products is a System Prob lem Repo rt (SPR) form . When conta cting the Technical Support Department for assistance with an installation or compatibility problem, we recommend that this form be complet ed and sent by facsimile or mail to MYLEX. Completion of t his form will allow our Technical Support Department to solve most te chnical problems expeditiously.
Mylex will make reasonable e fforts to address compa tibility proble ms which ma y arise with respe ct to third pa rty products, but shall not be responsible for the compa tibility of its products with the products of any third p ar ty. Cus­tomers are advised to verify each products compatibility with their installation before committing to any particular procurement plan.
Loading...