RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set; Preventing it from making contact with moving or hot objects.
Drywall dust or other fragments may be present in your replace’s vent space, clean this area before you install the blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
Blower Kit Parts Check the contents of the carton.
Make sure nothing was damaged in shipment. Do NOT install a damaged blower kit!
Description
Blower - Magnetic Mount
Thermodisc / Heat Sensor
Variable Speed Control
Cord Set
3-Prong to 2-Prong Adapter
Installation Instructions
Step 1: Turn Off Fireplace and allow it to cool down. Disconnect from 120V Power. Shut off
the Gas supply. Remove the louver which cov­ers the lower vent space below the rebox.
(Downloadable)
Qty.
1 1 1 1 1
1
Step 2: Connect green wire from power cord to green wire of motor; connect black and white wires of power cord to either black wire attached to motor. Push dis-
connects together, one plastic insulator ts inside the
other.
Position blower with rectangle air exit ports facing up and motor facing left. Slide blower into lower vent
space all center against the rear wall. (Figures: 1&3)
Lay cord set out in a straight line, with the 3-Prong Power Plug furthest away from the
replace.
Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2013
NOTE: Diagrams and Illustrations NOT to Scale
Figure: 1
Pull blower forward 1/8” to 1/4” from back wall of re­place. (Figure: 2)
Page 1 of 3
Burlington, Wisconsin
1-800-466-4045
1/8” TO 1/4 DISTANCE
FIREBOX AREA
FIREPLACE BACK WALL
BLOWER
Figure: 2
Step 2: Place the thermodisc to the underside
of the rebox. Typically, a couple inches back
from the front and 4-6 inches right of center is a good place. If this location does not get hot enough, try toward the rear and 4-6 right of center (Figure: 3,4)
MyFireplaceBlower.com:
Figure: 3
CLICK
THERMODISC / HEAT SENSOR PLACEMENT
The silver disc of the Thermodisc must be touching metal side of the rebox to sense
heat. The magnets will simply hold itself to the metal.
Step 3: The Varibale Speed Control may be
mounted on the right side of the lower vent
space or on the front of the center control panel.
Wipe off the mounting location to ensure it
is clean. Remove the clear backing of velcro
attached to Variable Speed Control and apply to the mounting location.
Turn the dial to the left and it will click off, turn right to reduce speed.
Figure: 4
You may want to wait and run blower a few times to see where you would like to mount the variable
speed control. The speed control must be in the ON position in order for the blower to run. The blower
will not turn on until the Thermodisc reaches approximately 120 degrees and the variable speed control
is in the ON position.
Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2013
NOTE: Diagrams and Illustrations NOT to Scale
Page 2 of 3
Burlington, Wisconsin
1-800-466-4045
Installation Videos:
CLICK
MY
FireplaceBlower
The fan will not run until the Thermodisc / Heat Sensor reaches approximately 120°F and the Variable Speed Control is turn to the “ON” Position! This means the Heat Sensor must be in contact with a hot spot on the underside of the Firebox.
Step 4:
Plug Blower into power Receptacle. Figure:5
Installation Instructions:
MyFireplaceBlower.com:
CLICK
CLICK
Finishing Steps: If appliance is connected to a gas supply, turn it back on.
If Appliance is connected to 120 Volt Power, turn it back on.
Figure: 5
My Fireplace Blower LLC produces and sells aftermarket replace blower kits; which require consultation of an Owner’s Installation Manual from the Manufacturer of a particular replace model number for in­stallation. During Installation of a replace blower kit or replacement blower, refer to the Owner’s Instal­lation Manual for your particular replace model to obtain supplemental information. My Fireplace Blower LLC is not responsible for any damage incurred during installation or resulting from installation of a re-
place blower kit, which was directed and/or conducted from the information within this document.
Installations in Canada must conform to the current CAN/CGAB-419.1 and .2 Gas Installation Code and local regula­tions. When installing the blower fan kit, it must be electrically grounded in accordance with CSA C22.1 Canadian
Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in absence of local codes or the National Fuel Gas Code, ANSI Z223.1-1988. When installing the blower fan kit, it must be grounded in accordance with local codes, or in
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987.
Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2013
NOTE: Diagrams and Illustrations NOT to Scale