My Fireplace Blower BK3 Instructions Manual

Installation Videos:
CLICK
Installation Instructions:
CLICK
MY
FireplaceBlower
High Quality Aftermarket Fireplace Blowers & Fans
MyFireplaceBlower.com:
Instructions for Design Version - BK3 Fan Kit
1-800-466-4045
CLICK
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set; Preventing it from making contact with moving or hot objects.
Drywall dust or other fragments may be present in your replace’s vent space, clean this area before you install the blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
Blower Kit Parts Check the contents of the carton.
Make sure nothing was damaged in shipment. Do NOT install a damaged blower kit!
Description
Fan - 3 Motor System
Power Cord Harness
ON/OFF Rocker Switch
3-Prong to 2-Prong Adapter
Hardware
Installation Instructions
Step 1: Turn Off Fireplace and allow it to cool down. Disconnect from 120V Power. Shut off the Gas supply.
(Downloadable)
Qty.
1
1 1
1 1 1
GLASS DOOR REMOVAL
Remove Glass Doors. (If applicable: Figure: 1)
Step 2: Remove the front refractory access
panel by lifting up and angling out through the
replace opening. (Figure: 2)
Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2015
NOTE: Diagrams and Illustrations NOT to Scale
Figure: 1
Page 1 of 3
Burlington, Wisconsin
1-800-466-4045
Step 3: Remove the control cover panel.
Remove the lower louver panel (if installed) by gently pushing out the
panel from behind, down inside the mounting frame.
Remove the knockout plug from the lower louver panel. (Figure: 2)
Heated Air out Top
Exhaust Air to Outside
MyFireplaceBlower.com:
CLICK
ACCESSING THE LOWER COMPARTMENT
FANS
Room Air in Bottom
Figure: 7
Step 4: Place the fan assembly with the blades pointing towards the rear of the
replace and in between the two leg stands. (Figure: 3 & 7)
Using 2 of the screws provided, fasten the upper ange of the blower bracket to
the hearth pan.
Then fasten the end anges to the leg
stands with the remaining 4 screws.
(Figure: 3)
Figure: 2
NOTE: Keep wire assembly away from the fan blades.
Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2015
NOTE: Diagrams and Illustrations NOT to Scale
Page 2 of 3
Figure: 3
Burlington, Wisconsin
1-800-466-4045
Installation Videos:
CLICK
MY
FireplaceBlower
Step 5: Remove the 2 connectors
from the ON/OFF rocker switch located on the wiring harness.
(Figure: 4)
Insert the rocker switch into the
lower louver panel with the switch lever pointing outward.
Connect the previously removed
wire connectors onto rocker switch.
Insert the power plug into one of
the available power receptacles. (Figure: 5)
Installation Instructions:
MyFireplaceBlower.com:
Figure: 4
CLICK
CLICK
Step 6: Reinstall the louver panel (if
Power Receptacle
equipped) into the framed opening with the louvers pointing upward. Replace the cover back over the
compartment opening.
Reinstall the front refractory panel.
Blower Supply Plug
Figure: 5
Reinstall glass doors in reverse or­der shown in Figure 1.
BLACK
To operate, turn the rocker switch to the ON position.
Figure 6 show the wiring diagram
Ground
for this fan kit.
My Fireplace Blower LLC produces and sells aftermarket replace blower kits; which require consultation of an Owner’s Installation Manual from the Manufacturer of a particular replace model number for in­stallation. During Installation of a replace blower kit or replacement blower, refer to the Owner’s Instal­lation Manual for your particular replace model to obtain supplemental information. My Fireplace Blower LLC is not responsible for any damage incurred during installation or resulting from installation of a re-
place blower kit, which was directed and/or conducted from the information within this document.
WHITE
GREEN
Figure: 6
Installations in Canada must conform to the current CAN/CGAB-419.1 and .2 Gas Installation Code and local regula­tions. When installing the blower fan kit, it must be electrically grounded in accordance with CSA C22.1 Canadian
Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in absence of local codes or the National Fuel Gas Code, ANSI Z223.1-1988. When installing the blower fan kit, it must be grounded in accordance with local codes, or in
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987.
Installer is responsible to check local codes and read all instructions prior to installation. Layout designed in U.S.A. © 2015
NOTE: Diagrams and Illustrations NOT to Scale
Page 3 of 3
Burlington, Wisconsin
1-800-466-4045
Loading...