MyFan The Modn-4, FP6722AU, FP6728AU Owner's Manual

The Modn-4
Ceiling Fan
Model No. FP6722**AU
OWNER’S MANUAL
READ AND SAVE THESE INSTRUCTIONS
Net Weight 8.87 kg (19.54 lbs)
Important Safety Instructions
WARNING: To avoid fire, shock and serious personal injury, follow these instructions.
1. Read your owner’s manual and safety information before installing your new fan. Review the accompanying assembly diagrams.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not insert anything into the fan blades while the fan is operating.
5. Do not operate reversing switch until fan blades have come to a complete stop.
6. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
7. Contact your local government for information regarding the collection systems available.
8. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
9. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
10. Children should be supervised to ensure that they do not play with the appliance.
Additional Safety Instructions
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring and installation procedures must comply with AS/NZS 3000 Wiring Rules and any local regulations. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation must be made by a licensed electrician.
3. The fan base must be securely mounted and capable of reliably supporting at least 27kg. See page 4 of owner’s manual for support requirements.
4. The fan must be mounted with the fan blades at least 2.1 meter from the floor to prevent accidental contact with the fan blades.
5. Follow the recommended instructions for the proper method of wiring this ceiling fan.
6. This fan is not suitable for use with solid state controllers. WARNING: This product is designed to use only those parts supplied with this product and/or accessories designated specifically for
use with this product. Using parts and/or accessories not designated for use with this product will void your warranty and could result in personal injury or property damage. WARNING: To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING:
The contact distance in all poles must be 3mm minimum.
This fan MUST be installed with an easily accessible isolating
device to disconnect all poles of the fan from the main supply.
Energy Effi cient Use of Ceiling Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Electrical and Structural Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .4
How to Hang This Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
How to Wire This Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Installing the Canopy Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Assemble the Ceiling Fan Blades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Table of Contents
Final Fan Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . snoitcurtsnI gnikcapnU
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blade Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exploded-View Illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 8 8
9
11
This manual is designed to make it as easy as possible to assemble, install, operate, and maintain this ceiling fan
Tools Needed for Assembly Materials
• One Phillips head screwdriver
(supplied)
• One stepladder
WARNING
This fan must be installed by a licensed electrician.
• One small blade
screwdriver
• One wire stripper
Wiring and connectors must be of type required by local regulations. The minimum wire would be a 3­conductor (2-wire with ground).
Unpacking Instructions
For your convenience, check-off each step. As each step is completed, place a check mark. This will ensure that all steps have been completed and will be helpful in fi nding your place should you be interrupted.
WARNING
Do not install or use fan if any part is damaged or missing. This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product. Substitution of parts or accessories not designated
for use with this product could result in personal injury
or property damage. IF ANY PART IS DAMAGED OR MISSING, CALL: 1300 469 326
1. Check to see that you have received the following
parts:
• Fan Motor Assembly
• Hanger Bracket
• End Plate Assembly
Blade Set Wall Control • Speed Capacitor
• Hardware bags:
– 3/16˝-24 screws with lock washer & flat washers (blade to fan motor flywheel)
– Phillips Screwdriver, 10 cm – Hex Washer Phillips Head Tapping Screws Ø4.8 – #8-32 Pan Head Screws
– Flat Washers
– External Tooth Washer – Spring Washer
NOTE: If you are uncertain of part description, refer to exploded view illustration. (Figure 1, page 10)
Hanger Bracket
Fan Motor Assembly
End Plate Assembly
Hardware Bags
Wall ControlSpeed Capacitor
Blade Set
3
snaF gnilieC fo esU tneic iffE ygrenE
Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan. Here are a few tips to ensure efficient product performance.
Choosing the Appropriate Mounting Location
Ceiling fans should be installed, or mounted, in the middle of the room and at least 2.1 m above the floor and 50 cm
from the walls. If ceiling height allows, install the fan
2.4-2.7 m above the floor for optimal airflow.
Turn Off When Not in the Room
Ceiling fans cool people, not rooms. If the room is unoccupied, turn off the ceiling fan to save energy.
Electrical and Structural Requirements
This new ceiling fan will require a grounded electrical supply line of 220-240 volts AC, 50 Hz circuit. The hanger bracket must be securely anchored and capable of supporting a load of least 27kg. If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture. Figure 1 depicts a typical structural configuration that may be used for securely mounting the fan.
WARNING
This fan must be installed by a licensed electrician.
Using the Ceiling Fan Year Round Summer Season: Use the ceiling fan in the counter-
clockwise direction. The airflow produced by the ceiling fan creates a wind-chill effect, making you “feel” cooler. Select a fan speed that provides a comfortable breeze, lower speeds consume less energy. Winter Season: Reverse the motor and operate the ceiling fan at low speed in the clockwise direction. This produces a gentle updraft, which forces warm air near the ceiling down into the occupied space. Remember to adjust your air conditioner when using your ceiling fan-additional energy and dollar savings could be realized with this simple step!
Ceiling
Ceiling
Ceiling
Joists
Joists
WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with AS/NZS 3000 “The Wiring Rules” and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
50 X 100 mm Timber Batten Between Joists
Figure 1
4
Loading...