MYERS MWH50, MW200, ME150, ME50 Installation And Service Manual

MWH50 - MW200 Series
ME50 - ME150 Series
Submersible Sump, Effluent & Sewage Pumps
Installation and Service Manual
Single and double seal. Single and three phase power.
Single Seal Pump
ME100S, ME150S,
MWH50, MW100,
MW150, MW200
©2012 23833A278 (03/15/12)
Double Seal Pump
ME50D, ME75D
ME100D, ME150D,
MWH50D, MW100D,
MW150D, MW200D
Typical Section Drawing For ME/MW50-200 Single Seal Pumps
1
2
3
4
5
OIL LEVEL
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
26
27
21
22
2” NPT
23
24
25
28
2
Single Seal Repair Parts List
Ref. Description Qty. Part Numbers
1 Nut, cord plug, solid 1 25341A002
2 Washer, 1/32” Thk. 1 05030A234
3 Gasket, Rubber 1 05014A193
4 Washer, 3/32” Thk. 1 05030A235
5 Plug, 1/4” pipe 1 05022A009
6 Cord, Power 1 See Chart
7 Screw, drive 2 05160A004
8 Name Plate 1 N/A
9 Housing, Motor 1 25327D000
10 Capacitor (1Ph only) 1 See Chart
11 Clip, capacitor (1 Ph only) 1 See Chart
12 Oil, Transformer .8-1 gal 11009A006
12A Connectors (3 Ph only) 3-6 15781A001
13 Washer, bearing 1 19331A005
14 Bearing, ball, upper 1 08565A013
15 Screw, st, #10 x 3/8 2 09822A032
Unit manufactured prior to Aug-2007 contact factory for repair parts.
Item Number 6 10 11 16 & 17 23
HP Volts PH
115 1 25338B004 208 1 230 1 25338B005 208 3
1/2
460 3 575 3 25484D103 115 1 25338B000 208 1 230 1 25338B001 208 3
3/4
460 3 575 3 25484D103 208 1 230 1 25338B001 25484D105 208 3
1
460 3 575 3 25484D107 208 1 230 1 25338B001 25484D105 208 3
1-1/2
230 3 460 3 575 3 208 1 230 1 26520A000 25484D109 208 3
2
230 3 460 3 575 3 25484D112
Power Cord
W/Plug
Power Cord
No Plug
25338B006
25338B002 23839A000 20333A006
25338B003
25338A002 23838A000 20333A004
25338B003
25338B002 23838A000 20333A004
25338B003 25484D106
25338B009
25338B008
25338B003
Capacitor
23839A000 20333A006
23839A000
Capacitor
Clip
20333A006
Ref. Description Qty. Part Number
16 & 17 Stator, Rotor shaft with shell 1 See Chart
18 Bearing, ball, lower 1 08565A022
19 Seal, shaft 1 25370A000
20 Plate, brg & seal 1 25367D000
21 Gasket, tetraseal, 7x6-3/4x1/8 1 05014A181
22 Screw, cap, 5/16 x 1-1/4 8 19100A012
23 Impeller 1 See Char t
Case, volute (ME50) 1 25357D000
24
Case, volute (ME75-150) 1 25331D000
Case, volute (MWH5-200) 1 26057D000
Cup, U, HUVA (ME50-150) 1 22835A005
25
Cup, U, HUVA (MWH50-200) 1 22835A009
26 Washer, Impeller Retainer 1 05030A242
27 Screw, Machine #10 x 3/8 1 06106A042
28 Sealant 1 14550A001
Stator Rotor
& Shaft
Ass’y
25484D100
25484D101
25484D102230 3
25484D100
25484D101
25484D102230 3
25484D104
25484D106230 3
25484D104
25484D108
25484D110
25484D111
ME
Impeller
Plastic
25333B025 25348B121 26029B013 26029B113
25348B020 25348B120
25348B010 25348B110 26029B012 26029B112
25348B000 25348B100 26029B011 26029B111
Impeller
ME
Brass
MWH
Impeller
DI
26029B000 26029B100
MWH
Impeller
Brass
3
Typical Section Drawing For ME/MW50-200 Double Seal Pumps
1
2
3
4
5
6
7
21
8
9
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
2” NPT
4
28
29
30
25
26
27
Double Seal Repair Parts List
Ref. Description Qty. Part Number
1 Cord, Sensor 1 25339B000
2 Cord, Power 1 See Chart
3 Screw, drive 2 05160A004
4 Name Plate 1 N/A
5 Housing, Motor 1 25327D000
6 Capacitor (1Ph only) 1 See Chart
7 Clip, capacitor (1 Ph only) 1 See Chart
8 Plug, 1/4” pipe 1 05022A009
9 Oil, Transformer 1.12 gal 11009A006
9A Connectors (3 Ph only) 3-6 15781A001
10 Screw, st, #10 x 3/8 2 09822A032
11 Washer, bearing 1 19331A005
12 Bearing, ball, upper 1 08565A013
13 & 14 Stator, Rotor shaft with shell 1 See Chart
15 Wire, electrode 2 21792A004
16 Screw, #6 x 1/4 2 05434A025
17 Seal Probe 2 25343A000
Unit manufactured prior to Aug-2007 contact factory for repair parts.
Item Number 2 6 7 13 & 14 25
HP Volts PH
115 1 25338B004 208 1 230 1 25338B005 208 3
1/2
460 3 575 3 25484D203 115 1 25338B002 208 1 230 1 25338B001 208 3
3/4
460 3 575 3 25484D203 208 1 230 1 25338B001 25484D205 208 3
1
460 3 575 3 25484D207 208 1 230 1 25338B001 25484D205
1-1/2
208 3
460 3 575 3 25484D207 208 1 230 1 26520A000 25484D209 208 3
2
230 3 460 3 575 3 25484D212
Power Cord
W/Plug
Power Cord
No Plug
25338B006 23839A000 20333A006
25338B003
25338B002 23839A000 20333A006
25338B003
25338B002 23838A000 20333A004
25338B003
25338B002 23838A000 20333A004
25338B003
25338B009
25338B008
25338B003
Capacitor
23839A000
Capacitor
Clip
20333A006
Ref. Description Qty. Part Number
18 Bearing, ball, lower 1 08565A022
19 Seal, shaft 1 25370A000
Ring, retaining 2 12558A021
20
Ring, retaining 1 12558A033
21 Gasket, tetraseal, 7x6-3/4x1/8 2 05014A181
22 Housing seal 1 25369D000
23 Plate, bottom 1 25368D000
24 Screw, cap 5/16 x 1-1/4 12 19100A012
25 Impeller 1 See Chart
Case, volute (ME50) 1 25357D000
26
Case, volute (ME75-150) 1 25331D000
Case, volute (MWH50-200) 1 26057D000
Cup, U, HUVA (ME50-150) 1 22835A005
27
Cup, U, HUVA (MWH50-200) 1 22835A009
28 Washer, Impeller Retainer 1 05030A242
29 Screw, Machine #10 x 3/8 1 06106A042
30 Sealant 1 14550A001
Stator Rotor
& Shaft
Ass’y
25484D200
25484D201
25484D202230 3
25484D200
25484D201
25484D202230 3
25484D204
25484D206230 3
25484D204
25484D206230 3
25484D208
25484D210
25484D211
ME
Impeller
Plastic
25333B025 25348B121 26029B013 26029B113
25348B020 25348B120
25348B010 25348B110 26029B012 26029B112
25348B000 25348B100 26029B011 26029B111
ME
Impeller
Brass
MWH
Impeller
DI
26029B000 26029B100
MWH
Impeller
Brass
5
I mportant Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this manual for future reference.
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury. NOTICE
personal injury.
seal are supplied with a grounding conductor and grounding-type attachment plug on the power cord. To reduce the risk of electric shock:
• Becertainthatitisconnectedonlytoaproperly
• DONOTcutoffgroundpinoruseanadapterfitting.
• DONOTuseanextensioncordwiththispump.
• Entireplugmaybecutoffifacontrolpanelisused.
• Alldoublesealpumps,allduplexinstallationsand
• Wh
All pumps have a GROUND WIRE that is connected to a screw in the metal motor housing. This wire goes to the receptacle or control box which must be connected to a good outside GROUND such as a metal water pipe or GROUND STAKE driven at least 8 feet into the ground.
When overload current protection is provided by installer:
USE WITH APPROVED MOTOR CONTROL
When motor has built-in overload protection:
USE WITH APPROVED MOTOR CONTROL
addresses practices not related to
Risk of electric shock. Pumps with a single
grounded, grounding-type receptacle.
all three phase pumps require a control box.
en wiring this pump follow all local electrical and safety codes and ordinances as well as the most recent National Electric Code (NEC-ANSI/NFPA 70).
THAT MATCHES MOTOR INPUT IN FULL LOAD AMPERES WITH OVERLOAD ELEMENT(S) SELECTED OR ADJUSTED IN ACCORDANCE WITH CONTROL INSTRUCTIONS.
THAT MATCHES MOTOR INPUT IN FULL LOAD AMPERES.
G eneral Description And
Application
Myers ME and MW series pumps are available in both a single seal design and double seal design with leak detector. The ME50-ME150 models are designed for Effluent dosing, Septic Tank Effluent Pumping (S.T.E.P.) or normal sump and general dewatering applications where higher pressure is required. These units are designed to handle ¾” spherical solids. The MWH50-MW200 models are designed for raw sewage applications and can pass 2” spherical solids. These units can also be used for sump and general dewatering applications where larger solids capabilities are required.
When used in Effluent dosing or S.T.E.P. applications, the pump must be installed in a separate tank or compartment at the discharger side of the septic tank.
Never install pump in tank where sludge collects.
These pumps are available in single phase and three phase, and either in single seal or double seal with seal leak detector. All three phase units, all double seal units and all duplex installations must be used with a control box. All power cords and seal leak detector cords are 20 feet long.
The ME model impellers are enclosed two vane type to handle ¾” spherical solids and are available made of engineered thermoplastic or cast brass. All pumps have a 2” NPT discharge tapping.
The MW model impellers are enclosed two vane non­clog style, designed to handle 2” spherical solids. The MW pumps are available with standard cast iron or optional cast brass impellers.
These pumps are NOT for use in swimming pools or fountains.
Air Locking
A sump pump is said to be air locked if water traps air in the pump and it cannot get out, thus preventing the pump from operating.
In installation of this type a 1/8” hole should be drilled in the discharge pipe just above the pump discharge. The check valve should be 12 to 18 inches above pump discharge. Do not put check valve directly into pump discharge opening. - follow local code.
Packaging
Each pump is packaged separately in a carton marked with a catalog number and Myers engineering number.
Level Controls
All pumps must use sealed level control switches for automatic operation. MLC and MFLC controls have sealed switches that are 1 HP rated at 230 volts. ALC and AWS-1 controls have sealed mechanical switches that are rated 2 HP at 230 volts.