Mydtcstore MAXDTC2-BT, MAXDTC6-BT User Manual

MAXDTC-BTFamilyUserManual
Description
The MAXDTC-BT is a fully programmable industrial temperature controller. The controller is configurable and monitorable thru a Bluetooth connection from your Android bluetooth enabled smartphone or tablet. The MAXDTC6-BT can run 6 independent programmable temperature control rules. The MAXDTC2-BT can run 2 programmable temperature control rules. All controllers have FLASH memory for saving and restoring configuration after power loss.
The controllers have either 2 or 6 external temperature sensor inputs (-40F - 300F / -40C
- 150C) and 2 or 6 dry relay contact outputs (120/240VAC @ 3A, 0-30VDC @ 3A) for switching
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 1
both AC and DC loads depending on model. The controllers are din rail mounted and powered by 12VDC. They have gray ABS enclosures and screw terminal for all connections.
Applications
Differential Heating and Cooling (Solar hot water heating, root cellar cooling, attic cooling)
Industrial Heat and Cool Thermostat/Alarming (-40F - 300F / -40C - 150C setpoints)
Outdoor Reset Control for Wood Boilers, with programmable one shot restart timer
Multi Input/Output Industrial Temperature Alarming
Remote control of all outputs from smart phone with one shot timer capability.
Greenhouse / hydroponics temperature control and alarming
Device Capabilities
Number of Control Rules Supported
MAXDTC2-BT
MAXDTC6-BT
Differential Temperature Control (Solar Heating or Root Cellar / Attic Cooling) (2 Inputs / 1 Output)
1
3
Thermostat (Heat or Cool) (-40 - 300F range) (1 Input / 1 Output)
2
6
Outdoor Reset Control (wood stove boiler) (2 Inputs / 1 Output)
1
3
Periodic Timer (0 Inputs / 1 Output)
2
6
Manual On/Off
2
6
Time Controlled One-Shot Boiler Reset / Remote Control Timed Run
2
6
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 2
Controller Specifications
Specifications
Relay Outputs: 0-240VAC/ 0-30VDC, 3 amps
Temperature Inputs: -40F - 300F Range, NTC 10K thermistor 1%
Power Input Voltage: 12vdc nominal (10.8V - 14V)
Power Input Current: 40mA + 16.7ma per active relay
Mounting: DIN RAIL
Indicator: Green LED
Communication: Bluetooth 2.0, Range: ~50ft line of site (nominal)
Configuration Memory: Non-Volatile, power fail safe
Enclosure / Size:
MAXDTC2-BT:
ABS/PC Blend, Gray, 1.429" L x 3.551" W (36.30mm x 90.20mm) X 2.264" (57.51mm)
MAXDTC6-BT:
ABS/PC Blend, Gray, 2.795" L x 3.551" W (70.99mm x 90.20mm) X 2.264" (57.51mm)
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 3
Installing a Bluetooth Terminal Program
In order to communication with the MAXDTC-BT controllers, you will need to load a Bluetooth Terminal program on your android smartphone or tablet. The program is free and can be downloaded for the Google Play Store.
The program that works best is Bluetooth Terminal HC-05 from mightyIT.
You can search for it and download it from the Google Play Store. Here is a link for it as well:
https://play.google.com/store/apps/details?id=project. bluetoothterminal&hl=en
First Connect to Bluetooth with Android
Before you can connect to the controller via the Bluetooth Terminal HC-06 program, you need to connect to the controller via the Bluetooth settings on your phone. You can navigate to the Bluetooth settings screen by going to Settings then selecting
Bluetooth. Once here, have the phone or tablet check for available devices. You will want to have
the controller powered up for a minute before doing this. When you scan for available devices, you should be able to find the controllers onboard bluetooth device which shows up as HC-06 or BT04-A. Once you see this, go ahead and select it to connect to the device. Once your phone has found and connected to the controller in this way, you are ready to connect to the controller with the Bluetooth Terminal HC-05 application.
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 4
In the bluetooth settings go ahead and pair with the discovered HC-06 device. You will need to enter a password to do this. The password for the HC-06 and BT04A bluetooth is 1234.
After pairing with the controllers bluetooth, you are ready to connect to it with the terminal application program.
Assuming you have loaded the serial terminal program, go ahead and run the Bluetooth
Terminal HC-05 application..
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 5
Here is the Bluetooth terminal application on one of the startup screens on the phone. When you run it you should see a connection choice for HC-06 or BT04-A like below if your have connected with the phone’s bluetooth settings previously.
After running the app it will show you a list of paired devices. Select the HC-06/BT04-A device. Once selected, the smartphone will attempt to connect to the controller. It should flash a connecting / connected message and take you to the terminal screen like shown below.
Go ahead and tap the enter command tab and hit an ‘s’ and then the Send button. The controller should respond with a Status display and the main menu. At this point you can monitor and configure your controller thru the application.
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 6
Configuring the Controller
Differential Heating and Root Cellar Modes (DIFF / ROOT)
These modes are used for solar hot water and air heating and root cellar or attic cooling. DIFF mode is used for heating. ROOT mode is used for differential cooling applications like root cellars..
Configure Differential or Root Cellar Menu Descriptions
Value
Range
Select Output to Configure (1-6):
1-6
Select Control Mode: 0-OFF, 1-ON, 2-HEAT, 3-COOL, 4-DIFF 5-ROOT, 6-RESET, 7-CYCLIC
4-5
Select Collector Temp Sensor (1-6): (ROOT Mode) Select Outside Temp Sensor (1-6):
1-6
Select Storage Temp Sensor (1-6) or (Root Mode) Select Cellar Temp Sensor (1-6):
1-6
Enter DeltaT TurnOn Degrees (1-99):
1-99
Enter DeltaT TurnOff Degrees (1-99):
1-99
Enter Max Tank Temp (0-255) or (Root Mode) Enter Min Cellar Temp (0-255):
0-255
Enter Freeze Protection? (1-yes, 0-no) or (ROOT Mode: None)
0-1
MAXDTC-BT User Manual - Rev A www.mydtcstore.com 7
Loading...