myAVR Board MK3 3.10 User guide

myAVR
technical description
myAVR
myAVRmyAVR
myAVR Board MK3
Technische Beschreibung
myAVR Board MK3 3.10
Version 3.10
Inhalt Contents
Allgemeine Beschreibung...............................................3
Eigenschaften.............................................................3
Das myAVR Board MK3.............................................4
Prinzipschaltbild myAVR Board MK3..........................4
Tochterplatine mySmartUSB MK3..............................5
Tochterplatine myAVR Stamp ....................................6
Technische Daten ..........................................................7
Betriebsdaten .............................................................7
Schnittstellendaten .....................................................7
Mechanische Daten .......................................................7
myAVR Board MK3.....................................................7
mySmartUSB MK3......................................................7
myAVR Stamp............................................................7
Schaltplan ......................................................................8
Schaltplan gesamt......................................................8
Schaltplan Auszug Programmierschnittstelle..............9
Schaltplan Auszug Taster und Joy-Stick ....................9
Schaltplan Auszug DIP-Schalter...............................10
Schaltplan Auszug LEDs..........................................10
Schaltplan Auszug 7-Segment-Anzeige ...................11
Schaltplan Auszug Grafik-LCD.................................11
Bestückungsplan..........................................................12
Programmereinstellungen............................................13
Programmereinstellungen SiSy AVR (ab 2.18b).......13
Programmereinstellungen in myAVR Workpad (1.5) 14
Programmereinstellungen in AVRDUDE (5.5)..........15
Programmereinstellungen in BASCOM (1.11.9.1)....16
Programmereinstellungen in Codevision (2.04.2).....17
Programmereinstellungen AVR Studio (4.15.623)....18
Boardtest......................................................................19
Spezielle Verbindungen ...............................................20
Quick Connect Option...............................................20
Spannungsversorgung auf dem myAVR Board MK320
Baugruppen mit Quick Connect................................21
Baugruppen mit fester Anbindung ............................21
Anwendungsbeispiel ....................................................22
Allgemeine Sicherheitshinweise...................................22
General description........................................................3
Properties................................................................... 3
The myAVR Board MK3 ............................................ 4
Principle circuit diagram myAVR Board MK3..............4
Daughterboard mySmartUSB MK3.............................5
Daughterboard myAVR Stamp...................................6
Technical Data............................................................... 7
Operating Data,.......................................................... 7
Interface Data.............................................................7
Mechanical Data ............................................................7
myAVR Board MK3 ....................................................7
mySmartUSB MK3 .....................................................7
myAVR Stamp............................................................7
circuit diagram................................................................8
complete.....................................................................8
circuit diagram extract programming interface............9
circuit diagram extract button and joy-stick.................9
circuit diagram extract DIP-switches.........................10
circuit diagram extract LEDs..................................... 10
circuit diagram extract 7-segment-display ................11
circuit diagram extract graphical lc display ...............11
layout diagram.............................................................. 12
Programmer settings....................................................13
changing setting in SiSy AVR (ex 2.18b).................. 13
changing setting in myAVR WorkPad (1.5) ..............14
changing setting in AVRDUDE (5.5)......................... 15
changing setting in BASCOM (1.11.9.1)................... 16
changing setting in Codevision (2.04.2)....................17
changing setting in AVR Studio (4.15.623)............... 18
Test of the board..........................................................19
special connections......................................................20
Quick connect option................................................20
Powering the myAVR Board MK3............................20
Assemblies with Quick Connect ............................... 21
Assemblies with mould gating .................................. 21
Example of use ............................................................22
Safety Guidelines.........................................................22
www.myAVR.de
Seite: 2/22
technische Beschreibung / technical description myAVR Board MK3 3.10
Die Informationen in diesem Produkt werden ohne Rück­sicht auf einen eventuellen Patentschutz veröffentlicht. Warennamen werden ohne Gewährleistung der freien Verwendbarkeit benutzt. Bei der Zusammenstellung von Texten und Abbildungen wurde mit größter Sorgfalt vorgegangen. Trotzdem können Fehler nicht vollständig ausgeschlos­sen werden. Die Autoren können für fehlerhafte Angaben und deren Folgen weder eine juristische Verantwortung noch ir­gendeine Haftung übernehmen. Für Verbesserungsvorschläge und Hinweise auf Fehler sind die Autoren dankbar.
Alle Rechte vorbehalten, auch die der fotomechanischen
All rights reserved. Unless otherwise specified, no part of Wiedergabe und der Speicherung in elektronischen Me­dien. Die gewerbliche Nutzung der in diesem Produkt gezeig­ten Modelle und Arbeiten ist nicht zulässig.
Fast alle Hardware- und Softwarebezeichnungen, die in
All trademarks and registered trademarks appearing in diesem Dokument erwähnt werden, sind gleichzeitig auch eingetragene Warenzeichen und sollten als solche be­trachtet werden.
© Laser & Co. Solutions GmbH
© Laser & Co. Solutions GmbH Promenadenring 8 02708 Löbau Deutschland
www.myAVR.de
Tel: ++49 (0) 358 470 222 Fax: ++49 (0) 358 470 233
In spite of the great care taken while writing this docu­ment the author is not responsible for the topicality, cor­rectness, completeness or quality of the information pro­vided. Liability claims regarding damage caused by the use of any information provided, including any kind of information which is incomplete or incorrect,will therefore be rejected.
this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher.
this document are the property of their respective owners.
Promenadenring 8 02708 Löbau Germany
www.myAVR.com
Tel: ++49 (0) 358 470 222 Fax: ++49 (0) 358 470 233
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
/ technical description myAVR Board MK3 3.10
Seite: 3/22
Allgemeine Beschreibung
Das myAVR Board MK3 ist ein leistungsfähiges Ent­wicklungsboard für Atmel Mikrocontroller. Auf diesem Entwicklungsboard sind die Komponenten myAVR Stamp und der Programmer mySmartUSB MK3 sowie ein Grafik­display bereits integriert. Es hat zahlreiche Hardware­Komponenten und Anschlussmöglichkeiten für die Ent­wicklung und das Testen von eingebetteten Systemen. Das Board ist in SMD-Bauweise ausgeführt. Alle SMD­Bauteile sind bestückt. Das myAVR Board MK3 besitzt für alle Komponenten eine "quick connect option"; d. h. alle Geräte können per Jum­per sofort zugeschalten oder bei Bedarf frei verdrahtet werden. Des Weiteren können alle Pins einzeln miteinan­der verbunden werden. Es gibt 4 Erweiterungsports sowie eine Anschlussoption für ein myAVR Board MK1 LPT/ MK2 USB oder einen mySmartControl. Ebenso besteht die Möglichkeit zur externen Spannungsversorgung, an der ein Netzteil angeschlossen werden kann. Das Board arbeitet mit 5 V und ist kompatibel zu den bis­herigen myAVR-Produkten. Es ist mit dem leistungsstar­ken 100-PIN-ATmega (64 bis 256 KByte Programmspei­cher) mit 16 MHz, einem Mini-USB-Anschluss mit unserem bewährten CP2102 und einem microSD-Kartenhalter aus­gestattet.
General description
The myAVR Board MK3 is an efficient development board for Atmel microcontrollers. On this board, the components myAVR Stamp, the programmer mySmartUSB Mk3 and a graphical display are already integrated. The board has many hardware components and also junctions to de­velop and test embedded systems. Furthermore, it is completely built in SMD and all the SMDs are already populated.
For all of the pre-installed components, there are “quick connect options” to switch the specific device on or if required to wire them. In addition all of the pins can be wired among themselves. There are 4 extension ports and a connection alternative for a myAVR Board MK1 LPT / MK2 USB or rather a mySmartControl. Also there exists the way to supply the voltage with an external AC/DC adapter.
The board operates with a voltage of 5 V and is compati­ble to all myAVR products up to now. It is equipped with a powerful ATmega microcontroller with 100 pins and a memory of 64 to 256 KByte at a clock frequency of 16 MHz. Further, there is a mini USB port, realized by a CP2102 multi chip and a microSD-card slot already pre­installed.
Eigenschaften
einfache Kommunikation mit dem PC oder Notebook über die USB-Schnittstelle
Kommunikation über UART, TWI, SPI möglich
Spannungsversorgung wahlweise über USB-
Anschluss oder externe Spannungsversorgung (9­12V)
16 MHz Prozessor mit bis zu 256 K Byte Speicher
Industriestandard-Controller (CP2102) USB zu seriell
Konverter (mySmartUSB und myAVR Stamp PLUS)
MicroSD-Kartenhalter (myAVR Stamp PLUS)
Mini-USB-Anschluss (myAVR Stamp PLUS)
in SMD-Bauweise
Eingabegeräte: 3 Analog-Geräte, 3 Taster*, Joy-
stick*, Lichtsensor, 8 DIP-Schalter*
Ausgabegeräte: grafisches LC-Display* 64 x 128, LED-Zeile* mit 8 LEDs, Speaker, 3 LEDs, 7-Segment-Anzeige*
updatefähig über Bootloader
Highspeed-Programmer (mySmartUSB); separat
nutzbar
Qualitätsleiterplatte FR4 gebohrt, verzinnt, Industrie­fertigung, robust, bedruckt
(* = mit "quick connect")
Properties
Communication between the board and the pc/notebook by USB interface
Following protocols supported: UART, TWI, SPI
Power supply optional via USB interface or external
power supply (9-12V)
16 MHz processor up to 256 K Byte memory
Industry standard controller (CP2102) USB to seriell
converter (mySmartUSB and myAVR Stamp PLUS)
microSD-Slot (myAVR Stamp PLUS)
Mini-USB-connection (myAVR Stamp PLUS)
In SMD designed
Input devices: 3 analog devices, 3 buttons*, joy-
stick*, photosensor, 8 DIP- switches*
Output devices: graphical liquid crystal display* 64 x 128, LED-strip* with 8 LED, Speaker, 3 LED, seven­segment display *
Renewable by bootloader
High speed programming (mySmartUSB), sepa-
rately useable
Quality printed circuit board FR4 pre-drilled, tin­plated, industrial production, solid, printed
(* = with “quick connect”)
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 4/22
8 LEDs
(digital)
myAVR Stamp
graphical lc display
+3,3V
VCC
Extern
speaker
technische Beschreibung / technical description myAVR Board MK3 3.10
Das myAVR Board MK3
mySmartUSB MK3
mySmartUSB MK3
Taster/Schalter (digital)
button/switch (digital)
Joy-Stick
Potentiometer (analog)
potentiometer (analog)
The myAVR Board MK3
myAVR Stamp mit RISC Mikrocontroller
myAVR Stamp with RISC µController
Grafik-LCD
graphical lc display
Schallwandler
speaker
LEDs
(digital)
7-Segment-Anzeige
7-segment-display
Prinzipschaltbild myAVR Board MK3
PC
USB
mySmartUSB Mk3
8 DIP-Schalter
8 DIP-switches
Joystick
Potentio­meter
potentio­meter
Licht­sensor
photo­sensor
+5V
+5V
Principle circuit diagram myAVR Board MK3
externe Spannungs­versorgung
external power supply
C0...7
A0...7 H0...7 K0...7
L0...7
B0...7
9-12V
+3,3V
Grafik-LCD
Daten / Steuerung /datas
controling
7 Segment Anzeige
7 Segment Display
Legende /
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
caption
Patchkabelbuchse /
patch cable socket
Technische Beschreibung
USB 2.0
Power
Zielsystem
target system
A
V
R
?
?
?
?
?2?
HV-Serial
?1?
?
High-Voltage-Parallel
serial HV
Power
UART Kommunikation
USB to SPI Bridge
/ technical description myAVR Board MK3 3.10
Tochterplatine mySmartUSB MK3
USB: Programmierung
und Kommunikation
USB: programming
and communikation
Seite: 5/22
Daughterboard mySmartUSB MK3
ISP Schnittstelle
ISP interface
JTAG Schnittstelle
JTAG interface
Das Board mySmartUSB MK3 ist ein kompakter Highspeed-USB-Programmer für Atmel Mikrocontroller. Es ist als Tochterplatine auf dem myAVR Board MK3 integ­riert; es kann auch separat auf eigenen Boards eingesetzt werden. Mit Hilfe des Boards mySmartUSB MK3 können Sie eine Vielzahl von AVR-Systemen einfach über die USB­Schnittstelle programmieren. Des weiteren verfügt das Board über eine JTAG-Schnittstelle und ISP-Anschluss. Das Kommunikationsinterface fungiert als UART, TWI/I²C oder SPI-Bridge. Die Kommunikation mit dem PC läuft völlig transparent über einen virtuellen COM-Port. Das Board wird per USB­Schnittstelle mit dem PC verbunden und mit Spannung versorgt. Es wird kein Parallel- oder Serial-Port benötigt, was speziell für Notebook-Besitzer von Vorteil ist. Der mySmartUSB MK3 arbeitet optional mit 3 V bzw. 5 V. Weitere Informationen finden Sie in der technischen Be­schreibung zu mySmartUSB MK3
virtual COM
Mode:
myMode
AVR109,911,910
STK 500
Data
mySmartUSB MK3
protocol-
communication
? ?
programming
?
direct-
communication
Quite
The mySmartUSB MK3 is a compact high-speed USB programmer for Atmel microcontroller. It is integrated as a daughter's board on myAVR Board MK3; it can be also used separately on own Boards.
You can program different AVR-systems via the USB interface with his board. Furthermore the board contains a JTAG and ISP connection. The communication interface works as an UART, TWI/I²C or SPI-bridge.
The communication with the PC is completely transparent and realized by the help of a virtual COM-port. The power supply is assured by the connection of the board to the PC. A parallel port is not necessary, what is particularly an advantage for notebook users. The mySmartUSB MK3 works optional with 3 V and 5 V. You find other information in the technical description to mySmartUSB MK3
SPI, TWI (I²C) ISP HV-Parallel
JTAG UART
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Power
on on
offLED Status:
USB 2.0
on or off 1x blink 2x blink
? 1 2
ISP6
JTAG10
Abbildung / picture:
Programmierung / programming
A
V
R
Auswahl durch Tastendruck: kurz=Mode, lang=Programmier-Mode
Choice by button: short=mode, long=program-mode
USB 2.0
USB to TWI Bridge
Power (VCC)
Abbildung / picture:
Kommunikation / communication
Seite: 6/22
Mini-USB
RxD
microSD
VCC=5V
3,3V
(CP2102)
RESET
ISP
JTAG
MISO
MOSI
RESET
RESET
F4...F7
mini USB
-
port (PLUS
-
version)
Tochterplatine myAVR Stamp
technische Beschreibung / technical description myAVR Board MK3 3.10
Daughterboard myAVR Stamp
ISP Schnittstelle
ISP interface
MicroSD-Kartenhalter (PLUS-Version)
microSD-slot (PLUS-version)
JTAG Schnittstelle
Mini-USB-Anschluss (PLUS-Version)
JTAG interface
Pinbelegung myAVR Stamp
Pin description myAVR Stamp
Prinzipschaltbild myAVR Stamp
ATmega
Quarz 16MHz
RXD3=J0
TXD3=J1
/SS=B0
SCK=B1 MOSI=B2 MISO=B3
F4...F7
Principle circuit diagram myAVR Stamp
TxD
SS SCK MOSI MISO
SCK SS
Ausführliche Informationen finden Sie in der technischen Beschreibung zu myAVR Stamp
You find detailed information in the technical description to mySmartUSB MK3
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
/ technical description myAVR Board MK3 3.10
Seite: 7/22
Technische Daten
Betriebsdaten
Versorgungsspannung ext. 9 – 12 V oder USB Betriebsstrom typ. 130 mA Betriebsspannung 5 V; max. 5,5 V Taktfrequenz 16 MHz Speicher FLASH 64-256 K Byte
Betriebstemperatur 0 – 30 °C
Schnittstellendaten
Programmierung und Kommunikation über USB 2: USB-Buchse für Anschluss an PC mit Standard-USB-Kabel A-B
SRAM 8 K Byte EEPROM 4 K Byte
Mechanische Daten
myAVR Board MK3
Abmessungen Platine (L x B x H) in mm Gewicht in g 155 Rastermaß in mm 2,54
180 x 118 x 19
Technical Data
Operating Data,
Supply Voltage ext. 9 – 12 V or USB Operating Current typ. 130 mA Operating Voltage 5 V; max. 5,5 V Clock frequency 16 MHz Memory FLASH 64-256 K Byte
Operating Temperature 0 – 30 °C
Interface Data
Programming and communication via USB 2: USB-pin for connection with PC via Standard-USB-cable A-B
SRAM 8 K Byte EEPROM 4 K Byte
Mechanical Data
myAVR Board MK3
Dimensions of the board (W x H x D) in mm Weight in g 155 Grid dimensions in mm 2.54
180 x 118 x 19
mySmartUSB MK3
Abmaße (L x B x H) in mm Gewicht in g 14 Rastermaß in mm 2,54
myAVR Stamp
Standard Plus Abmaße
(L x B x H) in mm Gewicht in g 10 12 Rastermaß in mm 1,27
65 x 31 x 15
38 x 45 x 7 38 x 45 x 10
mySmartUSB MK3
Dimensions (W x H x D) in mm Weight in g 14 Grid dimensions in mm 2.54
myAVR Stamp
Regular Plus Dimensions
(W x H x D) in mm Weight in g 10 12 Grid dimensions in mm 1,27
65 x 31 x 15
38 x 45 x 7 38 x 45 x 10
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 8/22
Schaltplan
g r
ü
n
g
r
ü
n
g
r
ü
n
g r
ü
n
g r
ü
n
g
r
ü
n
g r
ü
n
g r
ü
n
1
0 0
k
1
0 0
k
4
7
50k
1 K 2
1 K 2
1 K 2
1 K 2
1 K 2
1 K 2
1 K 2
1 K 2
F /
E E 1
7 P
7 4
V H C T 2
4 5
A
STROMSTECKE
R
2 4
5
A
HCT245A
HCT245A
5
V
+ 5
V
0 V
0
V
+ 3
,
3
V
+ 3
,
3
V
+ 5
V
+ 5
V
+
3 ,
3 V
0
V
0
V
+ 5
V
0
V
0
V
+
5
V
+ 5
V
0
V
+
5 V
+ 5
V
0
V
0
V
+ 5
V
0
V
+ 5
V
0
V
0
V
0
V
+
5 V
C14
C15
C16
C17
C18
C19
C 2
0
C 2
1
C 2
2
C 2
3
C 2
4
C25
C26
C27
C 2
8
2
4
R 1
0
R 1
3
R 1
8
1 2
S G 3
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
1
2
3
4
5
6
7
8
9
1
0
A0A1A2A3A4A5A6A 7
B0B1B2B3B4B5B6B 7
G N D
O E T /
R
V C C
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
123
4
123
4
/RD=E
/RS
T
/WR=R/W
A
A
A0=RS
C1+
C1-
C2+
C2-
C3+
C86=M
I
CS1
DB0
DB1
DB2
DB3
DB4
DB5
DB6,SCL
K
DB7,SID
K
K
P/S=P
S
V-OUT
V
0
V
1
V
2
V
3
V
4
VDD
VSS=GND
1
G
2S3
D
0
1
2
3
4
5
6
7
/
O E
A
0
A
1
A
2
A
3
A
4
A
5
A
6
A
7
B
0
B
1
B
2
B
3
B
4
B
5
B
6
B
7
G N D 1
G N D 2
G N D 3
T /
R
V C C
-
A
V C C
-
B
0
1
2
3
4
5
6
7
/
O E
A
0
A
1
A
2
A
3
A
4
A
5
A
6
A
7
B
0
B
1
B
2
B
3
B
4
B
5
B
6
B
7
G N D 1
G N D 2
G N D 3
T /
R
V C C
-
A
V C C
-
B
A10
B
9
C
7
COM13
COM28
D
5
DP6
E
4F2
G
1
1
2
3
4
A0A1A2A3A4A5A6A 7
B0B1B2B3B4B5B6B 7
G N D
O E
T /
R
V C C
1
2
3
4
A
0
A
1
A
2
A
3
A
4
A
5
A
6
A
7
B
0
B
1
B
2
B
3
B
4
B
5
B
6
B7GND
O
E
T/RVC
C
A
0
A
1
A
2
A
3
A
4
A
5
A
6
A
7
B
0
B
1
B
2
B
3
B
4
B
5
B
6
B7GND
O
E
T/RVC
C
123
4
123
4
0
1
2
3
4
5
6
7
1
2
0123456
7
0
1
2
3
4
5
6
7
0123456
7
1
2
0
1
2
3
4
5
6
7
123
1
2
12345612345612345
6
1
2
0
1
2
3
4
5
6
7
+
+
2
3
4
5
6
7
0
1
2
3
4
5
+
-
0
1
2
3
4
5
P O R T D
P O R T B
P O R T C
myAVRStam
p
D i
s
p l
a
y
T
e c
h 6
4 1
2 8 K (
3
V o
l
t
)
G r
a f
i
k
-
L C D
1 2 8
x 6 4 P i
x
e
l
7 4 L
V X C 3 2 4 5
7 4 L V X C 3 2 4 5
L C D
D A T
A
technische Beschreibung / technical description myAVR Board MK3 3.10
Schaltplan gesamt
B o
t
t
o
+
n
5
+
V
J
o
y o
n P o
0
r
V
t
K
I
I
R
R
L
L
M
M
L
L
6
6
4
4
0
0
2
2
0
V
P
P
P
P
P
P
P
P
P
P
2
1
1
1
1
1
1
1
1
1
1
0
9
8
7
6
5
4
3
2
12345
6
6
P20
6
P19
5
P18
4
P17
3
P16
2
P15
0
V
0
V
1 P14 P13 P12
6 P11
5
+
P10
4
5
V
P09
3 P08
2 P07
1 P06
6 P05
5 P04
4 P03
3 P02
2 P01
1
P20
6
P19
5
P18
4
P17
3
P16
2
P15
1 P14 P13 P12
6
+
P11
5
5
P10
4
V
P09
3 P08
2 P07
1 P06
6 P05
5 P04
4 P03
3 P02
2 P01
1
P
P
P
P
P
P
P
P
P
P
P
P
0
1
1
1
1
1
1
1
1
1
2
1
9
0
1
2
3
4
5
6
7
8
9
0
S V 9
0
V
0
V
0
V
10k
+ 5
V
123
123
4
122
1
1
PHOTO_R_VT93N1
2
3
-
W
1-N
6-S
4
5
-
-
0
E
G
2
V
-
N
C
D
E N T E R
12312
I
I
R
R
L
L
M
M
L
L
6
6
4
4
0
0
2
2
+
5 V
P
P
P
P
P
P
P
P
P
P
1
0
0
0
0
0
0
0
0
0
0
9
8
7
6
5
4
3
2
1
12345
12345
6
N C 1
N C 9
P
P
P
P
P
P
P
P
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
4
+ 5
V
0 V
+
1
1
2
2
0V
3
4
3
4
1
2
2
I
I
R
R
L
L
M
M
L
L
6
6
4
4
0
0
2
2
(
(
(
(
N
N
N
N
N
N
N
W
R
A
T
C
C
C
C
C
C
C
O
D
L
R
8
7
6
5
4
2
3
E
S
)
)
P
)
P
C
P
G
G
2
G
1
)
0
2
P G 3
N
N
N
N
N
N
N
N
N
C
C
C
C
C
C
C
C
C
1
1
1
1
1
1
1
1
1
8
4
6
7
3
5
2
1
0
ON
1 2 3 4 5 6 7 8
10k 10k 10k 10k
D I
P o
n P o r
t
-
H
1 2
3
4
S
S
S 8
(
(
O
T O
C
S
0 B
C
)
1
P
)
P
G
G
5
4
6
7
1
2
1
2
121
7
4 V H
B
B
B
6
5
7
C
G
T
N
A
A
2
D
6
7
4
5
A
0
V
I
I
R
R
L
L
M
M
L
L
6
6
4
4
0
0
2
2
(
(
(
(
(
(
X
O
R
O
O
T X
C
X
C
C
C
D
K
D
3
3
3
0
A
B
C
0
0
/
)
/
/
/
/
A
P
P
A
I
I
N
N
I
E
I
C
N
N
T
T
1
I
0
4
N
1
5
)
)
)
)
8
P
P
P
P
)
E
E
E
E
P
2
3
4
5
E 0
P J 2 (
X C
P
P
P
P
J
J
K
J
J
6
5
4
3
3
(
(
(
(
/
P
P
P
P
P
C
C
C
C
C
I
I
I
I
I
N
N
N
N
N
T
T
T
T
T
P
1
1
1
1
1
J
5
4
3
2
1
7
)
)
)
)
)
+
5
V
10k 10k 10k 10k
0
7
V
4
V H C T
1
1
1
1
R
R
R
R
R
,
,
,
,
4
4
4
4
4
8
8
8
8
8
9
5
6
7
k
k
k
k
(
(
(
(
(
(
(
(
(
(
A
A
A
A
A
A
A
C
A
T 3
D
D
D
D
D
D
D
L
D
/
K
C
C
C
C
C
C
C
C
I
N
O
0
1
2
3
5
4
6
7
T
)
)
)
)
/
/
/
/
/
T
T
T
T
P
P
P
P
I
6
C
M
C
D
D
F
F
F
F
)
P
P
0
1
2
3
K
O
I
S
)
E
3
P
)
)
)
P
/
6
P
P
I
F
N
F
F
F
7
T
4
5
6 7 )
P E 7
P
P
J
J
1
0
(
T
(
R
X
X
D
D
P
P
P
P
3 /
P C I
N T 1 0 )
P
P
P
3
H
H
H
H
H
H
H
/
5
3
4
6
0
P
2
1
P
(
(
(
(
(
(
(
C
H
O
O
O
O
R
X
T
I
7
C
X
C
X
C
C
C
N
(
D
D
4
K
4
4
2
T
T
C
A
B
B
2
2
2
4
9
)
)
)
)
)
)
)
)
)
P o r
t
-
H
circuit diagram
complete
0
V
+ 5
V
B
B
B
B
O
B
V
0
1
2
3
4
C
E
C
T
A
A
A
A
A
A
/
R
0
1
2
3
4
5
0
V
1
R
,
4
1
1
1
R
R
8
2
,
,
,
k
4
4
8
8
8
3
4
k
k
k
7 6 5
P o
4
r
t
3
-
K
2 1 0
P
P
P
K
K
K
2
1
0
(
(
(
A
A
A
D
D
D
C
C
C
1
9
8
0
/
/
P
P
/
P
C
C
C
I
I
N
N
I
N
T
T
T
1
1
1
7
6
8
)
)
)
P L 5 (
O C
P
P
5
L
L
C
7
6
)
P o r
t
-
L
0
V
(
(
(
(
(
(
P
P
P
P
P
K
K
3
4
(
(
A
A
D
D
C
C
1
1
1
2
/
/
P
P
C
C
I
I
N
N
T
T
1
2
9
0
)
)
P L 4 (
O C 5 B )
X
T
I
R
S
S
C
K
K
K
X
C
X
C
D
P
7
6
5
D
K
D
L
A
(
(
(
1
A
A
A
/
1
1
/
1
)
I
I
N
)
/
P
N
D
D
D
/
I
P
I
N
D
N
T
C
C
C
T
D
T
0
4
T
1
1
1
1
5
)
3
)
2
5
4
3
P
P
)
)
/
/
/
P
D
P
P
P
P
D
D
D
0
C
C
C
1
3
I
I
I
2
N
N
N
T
T
T
2
2
2
3
2
1
)
)
)
P
P
P
L
(
(
(
(
(
A
A
A
A
L
L
A
3
P
0
1
1
1
1
1
(
1
O
L
(
(
5
4
3
2
1
I
I
2
)
)
)
)
)
C
C
C
P
P
P
P
P
(
5
P
P
T
C
C
C
C
C
A
5
4
5
7
6
5
4
3
)
)
)
)
1
K 2
r
o t
0
V
L
E D
o
n P o
r
t
-
L
1
2
B 2
+ 5
V
L
B
B
D
D
D
D
X
X
X
R
S
S
A
A
T
A
A
A
A
E
m
A
T
T
T
T
2
1
0
1
A
A
A
A
A
L
D
y
1
7
6
5
4
S
Y
m a
r
D
D
t
U
D
A
A
A
T
T
S
T
A
A
W
O
B
A
2
3
R
P
R
D
E
1
\
\
A
E
M
M
M
\
A
\
\
G
R
V
S
G
T
S
T
O
I
K
X
N
S
C
C
X
E
A
E
S
O
D
D
D
C
K
V C C
AREF
RESET
RXD1
P o
r
t
-
C
3
T
I
0
V
+ 5
V
V C C
TCK TMS TDO
TDI
CLK
MISO MOSI
SCK
TXD1
G
G
N
N
D
D
0
V
+
5 V
74V
A R E F
R
3
4
E S E
1
2
T
0
V
P o r
t
-
A
+
5 V
P
L
C
O
D
R T
o
0
n
A
V
+ C
R
0
V
1
2
C S
L
C D C o n
t
r
o
l
0
L
(
(
(
(
(
(
(
(
(
(
O
O
M
O
M
O
T
T
S
S
1
0
S
C
C
C
C
C
O
I
S
)
)
/
K
0
2
1
1
P
P
S
P
O
A
A
B
A
/
D
D
I
C
P
/
/
/
/
/
/
P
P
6
7
O
P
P
P
I
C
N
C
C
C
C
C
I
C
T
N
I
I
I
I
I
1
N
N
0
N
N
N
T
C
)
T
T
1
T
T
T
P
/
2
3
)
P
4
6
5
B
P
)
)
)
)
)
C
P
P
P
P
P
0
B
B
B
I
B
B
B
1
N
2
3
4
6
5
T 7 )
P B 7
(
(
(
(
(
(
(
(
A
(
A
1 0
9
)
)
P
P
C
C
2
1
1
K 2
g
e
l
b
(
A
A
A
A
A
A
A
A
(
A
D
D
D
D
D
D
D
D
8
7
6
5
4
3
2
1
0
)
)
)
)
)
)
)
)
)
P
P
P
P
P
P
P
P
P
C
A
A
A
A
A
A
A
A
7
6
5
4
3
2
1
0
0
1
K 2
g
r
ü
n
F 5
I
N
0
G
/
N
O
7
D
8
U
0
T
5
P o
w e
r U S B \
E x
t
.
+ 5
0
V
V
D 2
l
o
w d
r
o
+
p
5
U
V
S
1
A
p
7
a
I
8
n
N
0
V
+ 5
V
R 1
1
M
n
O
u
3
U
n
3
T
g
C
+
s
3
D
v
3
,
C
e
3
r
V
Y
s
R
o
r
g
u
n g
+ 5
V
1
K 2
g
r
ü
n
0
V
+ 5
V 0 V
0
V
0
V
0
V
74V
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
/ technical description myAVR Board MK3 3.10
Seite: 9/22
Schaltplan Auszug Programmierschnittstelle
circuit diagram extract programming interface
Schaltplan Auszug Taster und Joy-Stick
circuit diagram extract button and joy-stick
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 10/22
technische Beschreibung / technical description myAVR Board MK3 3.10
Schaltplan Auszug DIP-Schalter
circuit diagram extract DIP-switches
Schaltplan Auszug LEDs
circuit diagram extract LEDs
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
/ technical description myAVR Board MK3 3.10
Seite: 11/22
Schaltplan Auszug 7-Segment-Anzeige
circuit diagram extract 7-segment-display
Schaltplan Auszug Grafik-LCD
circuit diagram extract graphical lc display
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 12/22
technische Beschreibung / technical description myAVR Board MK3 3.10
Bestückungsplan
layout diagram
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
Mode-Taster
mode-button
Taster kurz tippen
press button short
/ technical description myAVR Board MK3 3.10
Seite: 13/22
Programmereinstellungen
Programmereinstellungen SiSy AVR (ab 2.18b)
Versetzen Sie den USB-Programmer mySmartUSB MK3 in den Modus myMode (näheres dazu, finden Sie im Ab­schnitt zur Tochterplatine mySmartUSB MK3, sowie der Technischen Beschreibung zum mySmartUSB MK3). Starten Sie SiSy und legen Sie ein neues Projekt an. Im Programmfenster von SiSy klicken Sie das Symbol „klei­nes Programm“ mit der rechten Maustaste an und wählen „Definieren...“. Im sich öffnenden Fenster entfernen Sie das Häkchen „Vorgabe benutzen“ und klicken auf Hard- ware einstellen. Im myAVR ProgTool wählen Sie den USB Programmer mySmartUSB MK3 und klicken auf Test. SiSy übernimmt die Taktfrequenz, den verwendeten Controller und den COM-Port. Klicken Sie auf den erkann­ten Controller und anschließend auf Speichern. In diesem Beispiel wurde ein myAVR Board MK3 mit einer myAVR Stamp256 verwendet.
Status-LEDs
status-LEDs
Mode: myMode
Programmer settings
changing setting in SiSy AVR (ex 2.18b)
Put the mySmartUSB MK3 into the myMode compatibility modus (you find more informations to that, in the section of the mySmartUSB MK3 and in the technical description of the mySmartUSB MK3). Open an project or create a new one. To adjust the hard­ware, choosing right click on the project and "Definieren ...". Remove the checkmark "Vorgabe benutzen" and click on Hardware einstellen.
Adjusts via myAVR ProgTool the mySmartUSB MK3 Pro­grammer and click on Test button. SiSy get, the used controller, the COM port and the frequency. Now you click on the recognized controller and after that, on the Speichern button. In the example was used the myAVR Board MK3 with a myAVR Stamp256.
?
Prog-Mode: abhängig vom Zielsystem
prog-mode: depending on target system
Auswahl:
Choise:
Nach dem Speichern öffnet sich ein Informationsfenster welches anzeigt, dass die Einstellungen übernommen wurden.
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
An information window opens, after you haved used the Speichern button and confirm, that the attitudes were taken on.
Seite: 14/22
Mode-Taster
mode-button
Taster kurz tippen
press button short
technische Beschreibung / technical description myAVR Board MK3 3.10
Programmereinstellungen in myAVR Workpad (1.5) Versetzen Sie den USB-Programmer mySmartUSB MK3
in den Modus myMode (näheres dazu, finden Sie im Ab­schnitt zur Tochterplatine mySmartUSB MK3, sowie der Technischen Beschreibung zum mySmartUSB MK3). Starten Sie myAVR Workpad und wählen Sie im Menü­punkt Extras/Einstellungen den mySmartUSB MK3 Pro­grammer aus, klicken Sie auf Test. Den gefunden Control­ler übernehmen Sie, indem Sie diesen anklicken. Schlie­ßen Sie die Einstellungen mit der Schaltfläche Speichern ab. In diesem Beispiel wurde ein myAVR Board MK3 mit einer myAVR Stamp256 verwendet.
Status-LEDs
status-LEDs
Mode: myMode
?
changing setting in myAVR WorkPad (1.5)
Put the mySmartUSB MK3 into the myMode compatibility modus (you find more informations to that, in the section of the mySmartUSB MK3 and in the technical description of the mySmartUSB MK3). Choose in the menue under Extras/Einstellungen the myS­martUSB MK3 programmer and click on the Test Button. Click on the controller to take this. In the example was used the myAVR Stamp 256 PLUS with an ATmega2650. To complete the attitudes, use the Speichern button.
In the example was used the myAVR Board MK3 with a myAVR Stamp256.
Prog-Mode: abhängig vom Zielsystem
prog-mode: depending on target system
Auswahl:
Choise:
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
Mode-Taster
mode-button
Taster kurz tippen
press button short
/ technical description myAVR Board MK3 3.10
Seite: 15/22
Programmereinstellungen in AVRDUDE (5.5) Versetzen Sie den mySmartUSB MK3 Programmer in den
Mode AVR 109,911,910 (näheres dazu, finden Sie im Abschnitt zur Tochterplatine mySmartUSB MK3, sowie der Technischen Beschreibung zum mySmartUSB MK3). Starten Sie AVRDUDE über die Kommandozeile. Es wer­den Ihnen alle verfügbaren Befehle angezeigt. Hier ein Ausschnitt.
Status-LEDs
status-LEDs
Mode: AVR 109,911,910
?
Prog-Mode: abhängig vom Zielsystem
prog-mode: depending on target system
Hier sehen Sie einen Beispielbefehl zum Brennen eines Beispielprogramms.
changing setting in AVRDUDE (5.5)
Put the mySmartUSB MK3 into the AVR 109,911,910 compatibility modus (you find more informations to that, in the section of the mySmartUSB MK3 and in the technical description of the mySmartUSB MK3). After that start the AVRDUDE with the command line. That will show you all instructions, which are available. Here a clipping..
Auswahl:
Choise:
Here you see a command example to burn a program.
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 16/22
Mode-Taster
mode-button
Taster kurz tippen
press button short
technische Beschreibung / technical description myAVR Board MK3 3.10
Programmereinstellungen in BASCOM (1.11.9.1) Versetzen Sie den mySmartUSB MK3 Programmer in den
STK500 Mode (näheres dazu, finden Sie im Abschnitt zur Tochterplatine mySmartUSB MK3, sowie der Technischen Beschreibung zum mySmartUSB MK3). Unter dem Menüpunkt Options/Programmer können Sie die Einstellungen für den Programmer vornehmen. Hierzu wählen Sie, wie auf den Bildern ersichtlich, den Modus STK500 extended, sowie den COM-Port aus. Abschlie­ßend klicken Sie auf Ok und Ihre Einstellungen werden übernommen.
Status-LEDs
status-LEDs
Mode: STK500
?
Prog-Mode: abhängig vom Zielsystem
prog-mode: depending on target system
changing setting in BASCOM (1.11.9.1)
Put the mySmartUSB MK3 into the STK 500 compatibility modus (you find more informations to that, in the section of the mySmartUSB MK3 and in the technical description of the mySmartUSB MK3). You can carry out the attitudes for the Programmer under the menu item Options/Programmer. Then you will select the STK500 extended mode and as well as the respective COM port. In conclusion click on Ok and her attitudes were taken on.
Auswahl:
Choise:
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
Mode-Taster
mode-button
Taster kurz tippen
press button short
/ technical description myAVR Board MK3 3.10
Seite: 17/22
Programmereinstellungen in Codevision (2.04.2) Versetzen Sie den mySmartUSB MK3 Programmer in den
STK500 Mode. (näheres dazu, finden Sie im Abschnitt zur Tochterplatine mySmartUSB MK3, sowie der Technischen Beschreibung zum mySmartUSB MK3). Im Menüpunkt Settings/Programmer nehmen Sie als ers­tes die Einstellungen für den mySmartUSB MK3 Pro­grammer vor. Hierzu wählen Sie den Mode STK500, so­wie den Port. Bestätigen Sie die Einstellungen. Danach wählen Sie unter dem Menüpunkt Tools/Chip Programmer den passenden Prozessor aus, entsprechend dem Pro­zessor auf der myAVR Stamp und bestätigen ebenfalls. In diesem Beispiel wurde ein myAVR Board MK3 mit einer myAVR Stamp256 verwendet.
Status-LEDs
status-LEDs
Mode: STK500
?
Prog-Mode: abhängig vom Zielsystem
prog-mode: depending on target system
changing setting in Codevision (2.04.2)
Put the mySmartUSB MK3 into the STK 500 compatibility
modus. (you find more informations to that, in the section of the mySmartUSB MK3 and in the technical description of the mySmartUSB MK3). After that, you select in the menu Settings/ Programmer and you carry out the attitudes for the mySmartUSB MK3 Programmer. For that you choose the STK500 modus as well as the port. Confirm at the end. After that you configurate the Programmer under the menu item Tools/Chip Programmer, according to the processor on the myAVR Stamp and confirm. In the example was used the myAVR Board MK3 with a myAVR Stamp256.
Auswahl:
Choise:
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 18/22
Mode-Taster
mode-button
Taster kurz tippen
press button short
technische Beschreibung / technical description myAVR Board MK3 3.10
Programmereinstellungen AVR Studio (4.15.623) Schließen Sie das myAVR Board MK3 an das Rechner-
system an und versetzen den mySmartUSB MK3 Pro­grammer in den Mode STK500 (näheres dazu, finden Sie im Abschnitt zur Tochterplatine mySmartUSB MK3, sowie der Technischen Beschreibung zum mySmartUSB MK3). Starten Sie AVR Studio und wählen Sie den Menüpunkt Tools/Programm AVR/Connect... Wählen Sie hier, unter „Platform“ STK500, sowie den Port. Mithilfe der Schaltflä­che Connect wird nun die Hardware konfiguriert. Abhängig von der myAVR Stamp können Sie den Controller aus­wählen. Im Beispiel wurde die myAVR Stamp 256 PLUS mit einem ATmega2650 verwendet. Anschließend ändern Sie „Programming Mode“ und speichern die Einstellungen über die Schaltfläche Read Signatur. Als Ergebnis sehen Sie die Signatur der Hardware (vgl. Bild). Programme können Sie nun in der Registerkarte „Pro­gram“ mit Hex-Files laden.
Status-LEDs
status-LEDs
Mode: STK500
?
changing setting in AVR Studio (4.15.623)
At first you attach the myAVR Board MK3 to the computer system and put the mySmartUSB MK3 into the STK500 modus (you find more informations to that, in the section of the mySmart USB MK3 and in the technical description of the mySmartUSB MK3). Start the AVR Studio an choose in the menu Tool/Programm AVR/Connect… Now you select in the platform list “STK500”, your port and press on the “Con­nect” Button. The Software search the myAVR Board MK3. Addicted from the myAVR Stamp you can select the processor. In the example the myAVR Stamp 256 was used plus with an ATmega2650. After that, you must be changed the “programmer mode” and press the Read Signature button, to safe the settings. The results of that, you see the signature of the hardware (cf. picture). Your programms can be load with hex-files in the pro­gramm tab.
Prog-Mode: abhängig vom Zielsystem
prog-mode: depending on target system
Auswahl:
Choise:
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Technische Beschreibung
/ technical description myAVR Board MK3 3.10
Seite: 19/22
Boardtest
Voraussetzung für jedes Beispiel ist eine geeignete Spannungsver­sorgung, z.B. das myAVR Netzteil
Das Testprogramm erscheint beim Start. Zum Start gelangen Sie aber auch, wenn Sie Taster 1 drücken
Zum nächsten Testschritt gelan­gen Sie mit Drücken von Taster 3
Testverkabelung entsprechend Bild im Abschnitt „Allgemeine Be­schreibung“
Testprogramm muss auf Con­troller sein (Auslieferstandard)
Start:
Hauptmenü wird im Grafik LCD erzeugt
7-Segment-Anzeige gibt Zahlen aus
LEDs leuchten alle nacheinander
Weiter:
Ihnen erscheint das erste Font­beispiel, verschiedene Texttypen sind zu erkennen
Drücken Sie den Joystick, um sich ein weiteres Fontbeispiel anzuse­hen
Menüsystem / Menucontrol
Start
Zurück
Weiter
Home
Back
Next
Test of the board
A
suitable
necessary for all
Power supply is
examples, e.g.
the myAVR power supply unit
The test program starts if you connect the board. You can reach also the display if you press button 1
You always reach the next test step if you press button 3
Test cable system like the im-
age in the section “
scription”
Checkprogramm at the con­troller is needed
Home:
The main menu is shown on the graphic LCD
7-segment display shows num­bers
All LEDs are glown
press button 3 to continue
Next:
The first Fontexample occurs, dif­ferent texttypes are shown
press the joystick, to get another Fontexample
General de-
Weiter:
In der nächsten Anzeige, die Ih­nen erscheint, können Sie mit Hil­fe des Joysticks den Cursor belie­big bewegen
Weiter:
Zur Änderung des Kurvenverlaufs im Analogmenü drehen Sie am untersten Potentiometer bzw. vari­ieren den Lichteinfall auf den Lichtsensor
Weiter:
Schalten Sie nacheinander die DIP-Schalter ein
Im Grafik LCD kontrollieren Sie die Anzeige der eingeschalteten DIP-Schalter
Weiter:
Viele verschiedene Grafiken er­zeugen sich selbstständig
Hinweis: Die Beispiele stellen eine Auswahl aus dem gesamten Test­programm dar. Für einen Test mit der SD-CARD benötigen Sie eine FAT16-formatierte SD-Card mit Dateien in der Wurzel; z. B. myAVR Stamp PLUS.
Next:
you can move the cursor optional in the next display by the help of the joystick
Next:
If you want to change the curve shape at the analog menu you have to rotate the potentiometer or modify the flash at the light sensor
Please note:
These examples are a choise from the whole check­program. For a check with the SD-card you need an FAT16­formated SD-card with data at the radix; for example myAVR Stamp PLUS
Next:
Activate successive the DIP but­tons
At the subsequent menu on the graphic LCD you can notice, which DIP button you are acti­vated
Next:
Any number of graphics create themselves
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 20/22
technische Beschreibung / technical description myAVR Board MK3 3.10
Spezielle Verbindungen
Quick Connect Option
Die Quick Connect Optionen werden durch Jumper (blau) auf dem Board realisiert. Diese Jumper sind Schalteinheiten zwischen den verschiedenen Komponenten des Boards und bestimmten Ports des Prozessors. Bei der Quick Connect Option ist keine Verdrahtung notwendig, wodurch auch das Fehlerrisiko gesenkt wird. Das Ein – bzw. Ausschalten der Funktionen erfolgt durch Umstecken des Jumpers auf den Pins (siehe Bild).
Die Verbindung ist hergestellt, wenn der Jumper auf den rechten und mittleren Pin gesteckt ist. Diese Pins sind auf dem Board durch eine gelbe Linie markiert.
special connections
Quick connect option
The quick connect options will be realized via jumper (blue) which are on the board. The jumper are switch units between the different components of the board and specific ports of the processor. No cabling is nec­essary by the quick connect option. Thereby the error risk will be reduced. The switching-on or switching-off of the function hap­pens through the changing of the jumper on the pins (look to the picture). The connection is made when the jumper is inserted on the right and middle pin. These pins are marked on the board by a yellow line.
Verbindung geschalten
Durch Umstecken des Jumpers auf den mittleren und den linken Pin ist die Verbindung wieder getrennt (siehe Bild). Der linke Pin ist auf dem Bord nicht markiert.
Verbindung getrennt
Folgende Quick Connect Optionen können auf dem Board mittels Jumper geschalten werden:
Port K 0, K 1, K 2 Verbindung zu den Taster 1-3
Port K 3, K 4, K 5, K 6, K 7 Verbindung zum Joy-
stick
Port H Verbindung mit dem Schalter
Port A und Port C Verbindung zu dem Grafik LC-
Display
Port B Verbindung zu der 7- Segment Anzeige
Port L Verbindung zu den LEDs des Boards
Wenn eine dieser Funktionen nicht genutzt wird, sollte sie mit der Quick Connect Option getrennt werden.
Spannungsversorgung auf dem myAVR Board MK3
Die Spannungsversorgung über den USB Anschluss ist hergestellt, wenn der Jumper auf den linken und mittleren Pin gesteckt ist.
Connection is connected
The connection is disconnected by inserting the jumper on the middle and left pin (look to the picture). The left pin isn’t marked on the board.
Connection is disconnected
You can switch the following quick connect options on the board via jumper:
Port K 0, K 1, K 2 Connection to button 1-3
Port K 3, K 4, K 5, K 6, K 7 Connection to the
joystick
Port H Connection with the switch pushbutton
Port A und Port C Connection to the graphic
LC-display
Port B Connection to the 7 segment display
Port L Connection to the LEDs of the board
When you don’t use one of these functions than it should be disconnected by the quick connect option.
Powering the myAVR Board MK3
The power suplly via USB is connected if the jumper is inserted on the left and middle pin
Spannungsversorgung über USB Anschluss aktiv
Die externe Spannungsversorgung ist hergestellt, wenn der Jumper auf den rechten und mittleren Pin gesteckt ist.
Externe Spannungsversorgung aktiv
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
The external power suplly is connected if the jumper is inserted on the right and middle pin
Power supply via USB is connected
External Power supply is connected
Technische Beschreibung
Port
PortBPort
+5V
+5V
GND
GND
Port
Port
Port
/ technical description myAVR Board MK3 3.10
Seite: 21/22
Baugruppen mit Quick Connect
Port
myAVR
H
Stamp
Port
K
Assemblies with Quick Connect
Port
C
A
L
Baugruppen mit fester Anbindung
mySmartUSB
MK3
myAVR
Stamp
Assemblies with mould gating
+5V GND
www.myAVR.de © Laser & Co. Solutions GmbH - 02/2010 www.myAVR.com
Seite: 22/22
technische Beschreibung / technical description myAVR Board MK3 3.10
Beachte: Die konkreten Porteinstellungen sind von der Rechner­konfiguration abhängig. Besonders der USB Programmer mySmartUSB kann auf unterschiedlichen virtuellen COM Ports angemeldet werden. Es ist zu empfehlen, die COM Einstellung des mySmartUSB auf COM 3 oder COM4 zu legen, da manche Werkzeuge wie das AVR Studio maxi­mal COM4 zulässt. Die Zuweisung des COM Port erfolgt über den Gerätemanager
Anwendungsbeispiel
Notice:
The precise port settings depend on the configuration of your PC. Especially the USB programmer mySmartUSB might be assigned to different virtual com ports. We rec­ommend to use mySMartUSB with com 3 or com 4, as some tools (like AVR Studio) only support a com port up to com 4. You can change the com port settings in win­dows devia manager.
Example of use
myAVR Board MK3 mit myEthernet und myTWI Echtzeituhr /
myAVR Board MK3 with myEthernet and myTWI real time clock
Allgemeine Sicherheitshinweise
Grundsätzlich ist myAVR Board MK3 nur zum Einsatz unter Lern- und Laborbedingungen konzipiert. Er ist nicht vorge­sehen und nicht dimensioniert zur Steuerung realer Anla­gen. Bei vorschriftsmäßigem Anschluss und Betrieb treten keine lebensgefährlichen Spannungen auf. Beachten Sie trotzdem die Vorschriften, die beim Betrieb elektrischer Geräte und Anlagen Gültigkeit haben. Wir versichern, dass die Leiterplatte durch den Hersteller getestet wurde. Für fehlerhaften und/oder vorschriftswidrigen Einsatz des Boards übernehmen wir keine Garantie.
Die aktuellsten Dokumente zum myAVR Board MK3 finden Sie unter
The latest documents for the myAVR Board MK3 you can find at our homepage www.myAVR.com under „Download“.
Abbildungen können vom Inhalt abweichen. Änderungen im Sinne des technischen Fortschrittes behält sich der Hersteller vor.
Images may vary from the content. The manufacturers retains changes in terms of technical advances.
Safety Guidelines
The myAVR Board MK3 is designed for educational and experimental use only. It is not intended and not dimen­sioned to control real industrial facilities. At correct use there will not occur extremely dangerous voltages. Never­theless, be aware of general guidelines for using electronic devices. We assure that the PCB has been tested by the producer. For incorrect use and/or application contrary to technical regulations we are not liable.
.
www.myAVR.de im Downloadbereich.
www.myAVR.de © Laser & Co. Solutions GmbH – 02/2010 www.myAVR.com
Loading...