Marshall Electronics, Inc.
E-mail: Sales@mxlmics.com
Internet: www.MXLmics.com
MXL Cr-24
Vocal & Instrument
1910 East Maple Ave. El Segundo, CA 90245
Phone: (310) 333-0606 Fax: (310) 333-0688
Studio Condenser Microphone Kit
ank you for purchasing the MXL Cr-24 Vocal & Instrument Studio Condenser Microphone Kit. With proper care, this
microphone kit will provide many years of satisfaction. For best results, please take a few moments to review this literature.
General Characteristics
ese microphones have gold-sputtered diaphragms and a xed cardioid pickup pattern. Condenser microphones are very sensitive,
readily revealing very subtle sonic details. ey also tend to pick up sounds outside the pattern more than some designs, which can lead
to powerful feedback if you are not careful. We strongly advise experimentation with placement and isolation requirements with the
gain initially set low to avoid equipment (and hearing) damage. It is also strongly advised to use a mesh pop-lter to avoid moisture
from damaging the capsule.
Power Requirements
IMPORTANT: ese units require phantom power at 48 volts, +/- 4 volts. Each unit has been thoroughly checked before shipping, so
if you do not hear sound, check that the phantom power on your mixer or separate power supply is switched on!
-10dB Pad & Bass Roll-o Switch
Your Cr-24 Large Capsule Condenser Microphone includes a -10dB pad and bass roll-o switch. e -10dB pad allows this
microphone to be used in very loud sonic environments without signicant distortion. If you hear distortion from the microphone,
engage the “-10dB pad” on the back of the microphone to the -10dB position. You may also move the microphone farther away from
the sound source.
e Cr-24 also includes a bass roll-o switch to help reduce proximity eect. Proximity eect is distortion that often occurs when
a sound source is too close to the mic. Some microphone patterns boost bass as you get closer to the microphone; cardioid mics, for
instance, tend to boost bass. e bass roll-o switch reduces the low frequencies for a more full range sound.
Shockmount
e high isolation shockmounts may shift during shipping. Simply shift the elastic
bands to center the microphone in the assembly. Be sure that the wire clamp does
not rest on the chassis of the mount, as this impairs mechanical isolation. Slide the
mount all the way to the rim of the microphone grill for the most secure hold. To
attach the mics to the shockmounts, follow these instructions:
Microphone Cables
ese microphones connect to a mixer or preamp via XLR cable (not included).
e microphone cable can have a profound eect on the sound of any microphone.
Even the nest microphones will sound poor if the interconnect cable allows noise
to enter, or causes distortion and loss of information. Use only the best microphone
cable your budget will allow. We recommend Mogami cable for the best results.
Care
Dust and foreign material can degrade the performance of a microphone over time so always store the unit in its case. For vocals closer
than 3”, use a “popper stopper” or the included foam windscreens to avoid getting moisture on the diaphragm as this can substantially
degrade the microphones’ performance. Store the microphones in the ight case in a cool, dry place along with the included packet
of silica gel. When the mics are not in use or stored in the ight case, we recommend using the included leatherette pouches for extra
protection. We’ve even included handling gloves to avoid nger prints on your new Cr-24 microphones. ese steps will help keep the
mics in proper working order for many years to come.
Specications
MXL Cr-24 Large Capsule Condenser Microphone
Type:
Diaphragm:
Frequency Range:
Polar Patter
Sensitivity:
Impedance: 200 ohms
S/N Ratio:
Equivalent Noise Level:
Max SPL for 0.5% THD:
Power Requir
Curr
eight:
W
Size:
Metal Finish:
n:
ements:
ent Consumption:
Pr
essure gradient condenser mic
on gold sputtered
3-micr
20Hz - 20kHz
dioid
Car
-42.9 dB r
83 dB (Ref. 1Pa A-weighted)
11 dB (A-weighted IEC 651)
152dB SPL
48V phantom power (+/- 4V)
6.6mA
453.59g/1lb
50mm x 190mm/1.97 in. x 7.48 in.
Black chr
e 1 V/Pa
ome
Polar Pattern
0
Cr-24 Frequency Chart
MXL Cr-24p Instrument Microphone
Type:
Diaphragm:
Frequency Range:
Polar Patter
Sensitivity:
Impedance:
S/N Ratio:
Equivalent Noise:
Max SPL for 0.5% THD:
Power Requir
Curr
eight:
W
Size:
Metal Finish:
n:
200 ohms
18 dB (A weighted IEC 268-4)
ements:
ent Consumption:
Pr
essure gradient condenser mic
on gold sputtered
6-micr
30Hz-20kHz
dioid
Car
10mV/Pa
80 dB (Ref. 1Pa A-weighted)
134 dB SPL
48V phantom power (+/- 4V)
<3.0mA
130g/0.29lbs
22mm x 135mm/0.87 in. x 5.31 in.
Black chr
ome
Polar Pattern
2kHz
8kHz
180
180
V
O
90270
C
A
L
0
I
Cr-24p Frequency Chart
N
S
T
R
90270
U
M
E
N
T
Warranty
Marshall microphones are guaranteed against defects in material and workmanship for three years from date of purchase. Should you encounter any problem with this
unit, promptly contact the company you purchased it from for assistance. e original dated sales receipt will be necessary for any warranty claim. Do not send any unit
directly to us without prior authorization from our service department! Warranty coverage is limited to repair or replacement (at our option) of the microphone, and
does not cover incidental damages due to use of this unit, nor damage caused by accidental misuse of this product