Specifications
Environment
Application
Capacity
Compatible baluns
Orientation
Snap-in mechanism
Rack height
Enclosure
Mounting holes
Mounting hardware
Slot Id
Dimensions
Weight
Standards
Warranty
Order Information
Custom audio-video systems in a structured cabling environment.
Head-end installations, audio-video rooms, telecom rooms.
Sixteen (16) positions.
MuxLab baluns measuring: 2.4” x 2.25” x 1” (6.1 x 5.7 x 2.5 cm).
Baluns may be installed front or rear facing.
Baluns lock into position via spring latch mechanism.
2U (3.5”).
Black painted steel.
Four (4) rackmounting holes
Four (4) rackmounting 10-32 screws and washers are included.
Silkscreen on front and rear. Slots numbered “1” to “16”.
19” (W) x 3.5” (H) x 3.0” (D) (48 cm x 8.9 cm x 7.6 cm).
1.9 lbs (.86 kg).
EIA/TIA.
Lifetime.
500900 Rackmount Balun Chassis 16
8114 Trans Canada Hwy, St. Laurent, Quebec, Canada, H4S 1M5
Tel.: (+1) 514-905-0588 Fax: (+1) 514-905-0589
Toll Free (North America): (877) 689-5228
E-mail: videoease@muxlab.com URL: www.muxlab.com
94-000615-A SE-000598-A
Rackmount Balun Chassis 16 (500900)
Installation Guide
Introduction
The Rackmount Balun Chassis 16 is designed as a head-end cable management
solution, allowing any combination of up to sixteen (16) MuxLab square baluns to be
installed in a standard 19” telecom relay rack. Head-end AV equipment such as DVD
players, video servers and cable boxes may be installed in a local wiring closet and
connected to the Cat5 structured cabling system via a wide array of MuxLab balun
solutions.
The baluns may be installed in either front or rear- facing orientation depending on the
application. At the display end, the appropriate MuxLab baluns are installed at the
receivers to support a fully Cat5 cabling solution. Each balun snaps into place and is
held firmly by a spring latching mechanism. The product features a rugged one-piece
design for ease of installation and maintenance.
Installation
In order to install the Rackmount Balun Chassis 16 (500900), perform the following steps:
1. Identify the final location of the Rackmount Balun Chassis.
2. Install the Rackmount Balun Chassis in the 19” relay rack using the 10-32 rack
screws and nylon washers included with the product.
Rackmount Balun Chassis 16
© MuxLab Inc. 2007
3. Install each balun in its appropriate slot. In order to install each balun, push the balun
into the desired slot from the rear of the Balun Chassis. The slots are numbered “1”
to “16”. Each balun snaps into place and is retained by a spring-steel retaining clip.
4. The baluns may be installed either front or rear facing. In order to remove each
balun, lift the spring retaining clip at the rear of the chassis and pull out the balun in a
horizontal direction.
Balun
5. The following diagram shows a typical application.
© MuxLab Inc. 2007