8 Button IP PoE Control Panel Installation & Operation Manual
© MuxLab Inc. 2023 94-001000-A / SE-001000-A Page 11 / 21
Scene Settings
1. Set the name and click "Save" to Save the name.
2. Click "Back" to return to the scene page.
3. Click "Delete" to delete the scene.
4. Memory space used by the scene.
5. By selecting ON, the scene will not be displayed on the interface, but it can be
executed by invoking a command.
6. By selecting ON, when the scene is executed, it will repeat continuously.
7. Set the trigger mode for the scene, either every time the device is turned on
or a specific day and time.
(Note: Since the device does not have a battery and can only be used with a
constant power supply, it is necessary to synchronize the date and time every
time the power supply is interrupted by clicking the "Sync Time" button on
the System page).
Editing Commands in a Scene
1. Set the delay time, in milliseconds, before executing a command.
2. In this box the user can view, enter, or modify the programmed command.
3. Click "Tool" to enter the command generation page.
4. If “HEX” is selected, the command is displayed in hexadecimal format.
5. Click "Test" to test the command.
6. Click "Save" to save delay and command Settings.
7. Click "Delete" to delete the current command.
8. Click "Move Up" to move the command up in the execution sequence.
9. Click "Move Down" to move the command down in the execution sequence.
10. Click "Add Item" to add the command to the execution sequence.