MuxLab 500767-RX-MM Quick Start Guide

* MM F version shown
500767 3G-SDI/ST2110 over IP Uncompressed
Gateway Converter
Quick Installation Guide
The 3G-SDI/ST2110 over IP Uncompressed Gateway Converter allows HD-SDI and 3G-SDI equipment to be extended up to 100ft (30m) via UTP Cat 6a/7 cable or up to 1300ft (400m) via duplex multimode OM4 fiber with LC connectors, at up to 1080p resolution @ 60Hz uncompressed, in a point-to-point configuration. Point-to-multipoint and multipoint-to-multipoint configurations are also possible by connecting several units to a 10G Ethernet network. The unit provides a 1G Ethernet Switch port to connect additional network devices, and an RS232 port for remote control of end devices.
The 3G-SDI/ST2110 over IP Uncompressed Gateway Converter supports SMPTE ST-2110. It can be managed through its Web interface and RestAPI, please refer to the operation manual for further details about this.
Applications
Applications include commercial broadcast AV systems, news/sports/TV stations and movie networks/studios.
Installation
1. Identify the connectors on the Transmitter and Receiver as indicated on the product labels, see the above
front and rear product views for further details. Note that the MMF version is shown.
2. Install the SFP module, see below diagrams showing step by step instructions.
3. Verify that the distance between the 3G-SDI Transmitter and Receiver is within MuxLab
specifications (see Specifications table for further details).
4. To install the Transmitter:
a) Connect the Transmitter to the SDI video source with a COAX cable (Belden 1694A
recommended).
b) If the application is point-to-point, then connect one (1) length of Cat 6a/7 grade UTP cable to
the 10Gig port on the Transmitter. If transmitting over the network, use a 10 Gig Ethernet Switch between the TX & RX units.
5. To install the Receiver:
a) Connect the Receiver to the SDI display equipment with a COAX cable (Belden 1694A
recommended).
b) If the application is point-to-point, then connect one (1) Cat 6a/7 cable coming from the
© MuxLab Inc. 2019 94-000862-A SE-000862-A
Transmitter, to the 10Gig port on the Receiver. If transmitting over the network, use a 10Gig Ethernet Switch between the TX & RX units.
6. If the configuration is a point-to-multipoint or multipoint-to-multipoint:
a) You will need to use an Ethernet Switch with Gigabit ports and DHCP Server support. In addition
IGMP Protocol support is required for the multipoint-to-multipoint case. Verify that the
Ethernet Switch is configured correctly and that the DHCP Server is enabled and that the IGMP Protocol is enabled for multipoint-to-multipoint applications.
b) Connect all Transmitters and Receivers to the Ethernet Switch.
7. Connect the 12 VDC power supply to each Receiver and to an AC power outlet. Next connect each
Transmitter in the same manner. If power is present, the green power LED on each Transmitter and Receiver will illuminate.
Note: Power ‘ON’ the 3G-SDI / ST2110 over IP uncompressed gateway converter only after all
data connections have been made.
8. Power ‘ON’ the 3G-SDI equipment and verify the image quality.
9. The 500767 provides a 1GB Ethernet port to connect additional network devices (e.g. RestAPI control
software).
10. This product supports RS232 for remote control on end devices.
11. The following diagram illustrates a typical point-to-multipoint LAN configuration.
© MuxLab Inc. 2019 94-000862-A SE-000862-A