MuxLab 500136-US, 500136-UK, 500136-Eur Installation Manual

P/N: 94-000668-A, SE-000669-A
Passive CCTV Power Integrator Hub, 24VAC
(500136-US, 500136-UK, 500136-Eur)
Installation Guide
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
2
Table of Contents
1. Overview .................................................................... 4
1.1. Description..................................................... 4
1.2. Features.......................................................... 5
2. Technical Specifications............................................. 6
3. Installation Procedure................................................ 8
3.1. Parts List........................................................ 8
3.2. Product Overview........................................... 9
3.3. Pre-Installation Checklist...............................10
3.4. Physical Installation.......................................11
3.5. Installation Procedure....................................13
4. Troubleshooting........................................................19
5. Distance Tables .........................................................21
6. Product Warranty Policy..........................................23
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
3
Copyright Notice :
Copyright © 2011 MuxLab Inc. All rights reserved.
Printed in Canada. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without prior written permission of the author.
Trademarks :
MuxLab is a registered trademark of MuxLab Inc.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit and related equipment to rain or moisture. Assure the peripherals like cameras, DVR’s, switches, etc., are of type SELV (Safe Extremely Low Voltage). Particularly the outdoor camera must be of type Integral Isolated Camera Power. The mentioned equipment must be manufactured and connected in respect to all local safety codes ensuring that the grounds of adjacent devices are connected to the same local ground net. This installation should be carried out by qualified service personnel and should conform to all local safety codes.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside. Refer servicing to qualified service personnel.
CAUTION: Passive CCTV Power Integrator Hub is intended to be used in
a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, for example, in a telecommunication center, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and the installation is provided by a SERVICE PERSON.
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
4
1.
Overview
1.1. Description
The Passive CCTV Power Integrator Hub (500136) allows video, remote power and PTZ control to be transmitted via one 4-pair Cat5e/6 cable, thus eliminating the need to install multiple cables for more efficient cabling in the security video environment.
The product features a built-in 16-channel 350VA CCTV power supply that supplies 24Vac or 28Vac power to each CCTV camera and works in conjunction with MuxLab’s 500000R, 500009, 500022, 500023, 500024, 500029, 500120, 500122 and 500130.
Each hub port features two slide-switches; one for remote power and one for Power-Thru or Pass-Thru mode according to the application.
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
5
1.2. Features
Power 350VA; 24Vac or 28 Vac individually
selected and protected, transmitted through each port.
Slide-switch to set each port to Pass-Thru Mode
(500022) or Power-Thru Mode (500024/500029).
Slide-switch to set each port to 24Vac, or 28 Vac or
“OFF”.
Auto-resettable fuses on each port. Seamless integration with 500000R, 500022, 500024
and 500130.
Pin configuration chart on unit. 2U rack height. Remote-power LED indicators. cUL, FCC, CE compliance. 5 year warranty
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
6
2.
Technical Specifications
Specifications
Environment Composite video; NTSC, PAL, SECAM Devices CCTV cameras, DVRs, monitors, switchers, multiplexers and other
CCTV equipment
Transmission Transparent to the user
Video
Bandwidth DC to 8 MHz Maximum Input 1.1Vp-p Insertion Loss Less than 2 dB per pair over the frequency range Return Loss Greater than 15 dB over the frequency range from 20 Hz to
8 MHz
Common Mode Rejection Greater than 40 dB @ 8 MHz Ground Loop Isolation Not applicable Max. Distance - Color Cat 3 –1,200 ft (365m); Cat5e/6 – 2,200 ft. (670m)*
*Shorter distances will result with DVR equipment. Typically 1,000 to 1,500 ft
Max. Distance - B&W Cat 3 –1,500 ft (457m); Cat5e/6 – 2,500 ft (762m)
Remote Power
Switch Mode Pass-Thru Mode (500022)
Power-Thru Mode (500024/500029)
Number of twisted pairs Two (2) Three (3) Max. Distance @ 24VAC*
*Based on 10% voltage drop at camera. Longer distances may be achieved @ 28 VAC.
5 VA: 350 ft (107m) 10 VA: 175 ft (53m) 20 VA: 90 ft (30m) 30 VA: 60 ft (20m)
5 VA: 518 ft (170m) 10 VA: 259 ft (85 m) 20 VA: 130 ft (43 m) 30 VA: 86 ft (28 m)
Maximum Power Rating 350 VA, 60 Hz Voltage Selector Switch Sets port to 24 Vac or 28 Vac or “OFF”. Factory default: “OFF” Maximum Input Voltage & Current rating
500136-US: 120 Volts ac, 3.5 Amps, 60 Hz 500136-UK or 500136-Eur: 240 Volts ac, 1.75 Amps, 50Hz
Max Output Voltage per port
28 Vac or 24 Vac @ full load; 31 Vac or 27 Vac @ no load
Max Output Power per port
22 VA @ 28 Vac or 16 VA @ 24 Vac
Max Output Current per port
0.78 A ac
Fuses Auto-Reset type, all ports individually protected, no service required LED Indicators Master Power ON, green;
16 Ports Power On, green
2-Wire PTZ Control (i.e. RS-422, Manchester/Bi-Phase, half duplex RS485) – Pass­Thru Mode (500022)
Wiring Remote 2-wire PTZ control supported via one (1) twisted pair.
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
7
Maximum Distance Up to 4,000 ft (1.2 km) depending on the PTZ camera vendor**
**Please consult your CCTV equipment vendor for more detailed
performance specifications.
Mechanical & Environmental
Cable – UTP 24 AWG or lower solid copper twisted pair wire impedance: 100 ohms at
1 MHz Maximum capacitance: 20 pf/foot Attenuation: 6.6 dB/1000 ft at 1 MHz
Cable – Coax Impedance: 75 Ω at 1 MHz. (RG59/U)
Max. 25 ft. of coax allowed end to end
Connectors Video (Model 500136): Sixteen (16) BNC-F jacks
Control: Sixteen (16) 2-pole screw terminals Combined signals: Sixteen (16) RJ45 jacks
Port Configuration Switch
Sets each port to Pass-Thru Mode (500022) or Power-Thru Mode (500024/500029)
RJ45 Pin Configuration*
Signal 500022 Mode
500024/500029 Mode
*Reverse polarity
Power A (+) 1, 3 1, 3, 5
sensitive
Power B (-) 2, 6 2, 4, 6 Control (+) 4 Not used Control (-) 5 Not used Video BNC Center (Tip) 7 [T] same as
500000R
7 [T] same as
500000R Video BNC Ground (Ring)
8 [R] same as 500000R
8 [R] same as
500000R
Temperature Operating: 0° to 40°C.
Storage:-20° to 85°C. Humidity: up to 95%
Enclosure Black, anodized aluminum Dimensions 19” (48.26 cm) W x 3.5” (8.8 cm) H x 9.0” ( 23 cm) D Weight 23 lbs. (11kgs) Regulatory cUL, FCC, CE Warranty 5 years Order Information 500136-US Passive CCTV Power Integrator Hub, US (120V)
500136-UK Passive CCTV Power Integrator Hub, UK (220V) 500136-Eur Passive CCTV Power Integrator Hub, Eur (220V)
© MuxLab Inc . Passive CCTV Power Integrator Hub Installation
Guide
8
3.
Installation Procedure
3.1. Parts List
The Passive CCTV Power Integrator Hub comes with the following parts. Please verify that all pieces are present before proceeding.
Base Unit (Factory configuration: Power-Thru Mode
(500022), Voltage Selector Switch: “OFF”)
Power cord for US, UK or Continental Europe Two (2) "L" brackets and four (4) Philips 4-40
screws