Mutable Instruments Ripples Quick Start

Installation
Ripples requires a -12V/+12V power supply (2x5 pin connector). The red stripe of the ribbon cable (-12V side) must be oriented on the same side as the “Red stripe” marking on the module and on your power distribu­tion board.
Calibration
If necessary, adjust the trimmer on the left side of the module so that the tone emitted by the fi lter (when it self-oscillates) tracks a CV sent to the
V/OCT CV input.
Ripples
Online manual and help
The full manual can be found online at
mutable-instruments.net/modules/ ripples/manual
For help and discussions, head to
mutable-instruments.net/forum/
Please refer to the online manual for detailed information regarding compliance with EMC directives
Liquid fi lter
A
D E
1
Controls
A. Cutoff frequency.
B. Filter slope. The lower
position corresponds to a 12dB/octave slope (2-pole),
B
C
the upper position to a rounder 24dB/octave (4-pole). The BP and LP outputs are affected.
C. Resonance. Goes up to
self-oscillation.
D. Input 1 level, with a tasty
analog soft-clipping.
E. FM Attenuverter. Adjusts
the amount and polarity of frequency modulation from the
1
corresponding CV input.
Inputs and Outputs
2
3
4
1. Audio inputs. Input 1 goes
through a soft-clipping circuit, while input 2 is always clean.
2. CV inputs for cutoff modula-
tion, resonance, cutoff modula­tion with V/Oct tracking.
3. Voltage controlled gain for
the LP output.
4. HP, BP and LP filter out-
puts. The slope of the HP out-
put varies with the resonance.
Loading...