Ba si c Sy st em A rc hi te ct ur e ....... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. ... ..2
Prod uc t Ov er vi ew . ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ... .. . .3
Un pa ck in g an d In sp ec ti on .... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. . .4
Mo un ti ng t he U ni t ......... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ..........4
Ba tt er y Co nn ec ti on ...... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ..... ... .5
AC Inp ut / Ou tp ut C on ne ct ion ..... .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. ... ..6
Fi na l As se mb ly .......... .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ....... . ... 10
Co mm un ic at io n Co nn ection .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. ... . . ... 10
Tabl e 1 Li ne M od e Sp ecification s .. .. .. .. ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ....23
Tabl e 2 In ve rt er M od e Sp ec if ications .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. ............. .. .. .....24
Tabl e 3 Ch ar ge M od e Sp ecification s .. .. .. ............. .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. 25
Tabl e 4 Ge ne ra l Sp ec if ic ations .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .. ........... .. .. .. .. .. .. .. ............. .. .. .. .. .. .. .2 6
This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual
carefully before installations and operations. Keep this manual for future reference.
Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
The following cases are not within the scope of warranty
1. Out of warranty.
2. Series number was changed or lost.
3. Battery capacity was declined or external damaged.
4. Inverter was damaged caused of transport shift, remissness, ect external factor
5. Inverter was damaged caused of irresistible natural disasters.
6. Not in accordance with the electrical power supply conditions or operate environment caused damage.
SAFETY INSTRUCTIONS
WARNING: This chapter contains important safety and operating instructions. Read and keep
this manual for future reference.
1. Before using the unit, read all instructions and cautionary markings on the unit the batteries and all appropriate
sections of this manual.
2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types
of batteries may burst, causing personal injury and damage.
3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect
re-assembly may result in a risk of electric shock or fire.
4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning
off the unit will not reduce this risk.
5. CAUTION --Only qualified personnel can install this device with battery.
6. NEVER charge a frozen battery.
7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It' s
very important to correctly operate this inverter/charger.
8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to
spark or short circuit batteries or other electrical parts and could cause an explosion.
9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to
INSTALLATION section of this manual for the details.
10. GROUNDING INSTRUCTIONS- This inverter/charger should be connected to a permanent grounded wiring
system. Be sure to comply with local requirements and regulation to install this inverter.
11. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following
troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
1
INTRODUCTION
This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer
uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and
easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input
voltage based on different applications.
Features
Pure sine wave inverter
Configurable input voltage range for home appliances and personal computers via LCD setting
Configurable battery charging current based on applications via LCD setting
Configurable AC/Solar Charger priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload/ Over temperature/ short circuit protection
Smart battery charger design for optimized battery performance
Cold start function
Basic System Architecture
The following illustration shows basic application for this inverter/charger. It also includes following devices to have
a complete running system:
Generator or Utility.
Battery
PV modules
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such
as tube light, fan, refrigerator and air conditioner.
PC
TV
Air-
conditioning
Fridge
Washingmachine
Load
INVERTER
Figure 1 Hybrid Power System
2
PV INPUT
AC INPUT
BAT INPUT
BAT CHARGER
PV
-
+ -
+
Power Grid
Generator
Battery
Product Overview
INVERTER
Solar Inverter
7 8
10
9
15 1 6
13
11 12
USB
AGS
BTS
14
WIFI
20
18 19 20
17
1
4KW-12KW single model
NOTE: For parallel model installation and operation,
please check separate parallel installation guide for
the details.
2
Solar Inverter
3 456
1.Power saver on/off switch
2.LCD display
3.Status indicator
4.Discharging/Charging indicator
5.Fault indicator
6.Function buttons
7.Remote control port
8.BAT -
9.FAN
10.BAT +
11.WI-FI port
12.USB communication port
13.AC input /bypass breaker
14.AC output breaker
15.AGS(Auto Generator Start)
16.BTS
17.AC input
18.AC output
19.PV input
20.Ground
3
INSTALLATION
Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have
received the following items inside of package:
The unit x 1
User manual x 1
USB cable x 1
Software CD x 1
BTS Line x 1(Option)
WIFI Key x 1(Option)
Remote Line x 1(Option)
Preparation
Before connecting all wirings, please take off bottom cover by removing six screws as shown below.
IN
VE
R
TER
Mounting the Unit
Consider the following points before selecting where to install:
Do not mount the inverter on flammable construction materials.
Mount on a solid surface.
Install this inverter at eye level in order to allow the LCD display
to be read at all times.
For proper air circulation to dissipate heat, allow a clearance of
approx. 50cm to the side and 80 cm above and below the unit.
The ambient temperature should be between 0 c and 40 c to
ensure optimal operation.
The recommended installation position is to be adhered to the
wall vertically.
Be sure to keep other objects and surfaces as shown in the
diagram to guarantee sufficient heat dissipation and to have
enough space for removing wires
oo
INVERTER
SUITABLE FOR MOUNTING ON CONCRETE OROTHER
NON-COMBUSTIBLE SURFACE ONLY.
4
Install the unit by screwing six screws
INVERTER
INVERTER
Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current
protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in
some applications, however, it's still requested to have over-current protection installed. Please refer to typical
amperage in below table as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use
appropriate cable for battery connection. To reduce risk of injury, please use the
proper recommended cable and terminal size as below.
Recommended battery cable and terminal size:
Typical Amperage
Model
4024200A400AH
5024
4048
5048
6048
8048
10048
12048
Please follow below steps to implement battery connection:
1. Assemble battery ring terminal based on recommended battery cable and terminal size.
250A
100A
130A
150A
200A
250A
300A
Battery Capacity
600AH
400AH
600AH
800AH
1000AH
1200AH
1400AH
Wire Size
2*2AWG
2*1AWG
1*2AWG
1*1AWG
2*3AWG
2*2AWG
2*1AWG
3*2AWG
Torque Value
2~ 3 Nm
2~ 3 Nm
2~ 3 Nm
2~ 3 Nm
2~ 3 Nm
2~ 3 Nm
2~ 3 Nm
2~ 3 Nm
5
NOTE: Please only use sealed lead acid battery or sealed GEL/AGM lead-acid battery.
3. Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure the bolts are
tightened with torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charge is correctly
connected and ring terminals are tightly screwed to the battery terminals.
WARNING: Shock Hazard
Installation must be performed with care due to high battery voltage in series.
CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal.
Otherwise, overheating may occur.
CAUTION!! Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
CAUTION!!Before making the final DC connection or closing DC breaker/disconnector, be sure positive
(+) must be connected to positive (+) and negative (-) must be connected to negative (-).
AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and
AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully
protected from over current of AC input. The recommended appropriate of AC breaker is 40A for 4KW-6KW, 80A for
8KW-12KW.
CAUTION!! Please don't connect the output wring to "INPUT" terminal or connect the grid wring to the "OUTPUT"
terminal.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input
connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for AC wires
Torque ValueModelGauge
4KW-5KW10 AWG1.4~ 1.6Nm
6KW-8KW
10KW-12KW
8 AWG
2*10 AWG
1.4~ 1.6Nm
1.6~ 1.8Nm
6
Please follow below steps to implement AC input/output connection:
BTS
USB
AGS
BTS
WIFI
1. Before making AC input/output connection, be sure to open DC protector or disconnector first.
2. Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3mm.
3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure
to connect PE protective conductor ( ) first.
Ground (yellow-green)
L LINE (brown or black)
N Neutral (blue)
WARNING:
Be sure to that AC power source is disconnected before attempting to hardwire it to the unit.
4. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws.
Be sure to connect PE protective conductor ( )first.
Ground (yellow-green)
L LINE (brown or black)
N Neutral (blue)
5. Make sure the wires are securely connected.
CAUTION: Important
Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility
short-circuited when these inverters are worked in parallel operation.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to
have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short
time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer
of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter/charger will
trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the
air conditioner.