Mustang Survival MD1250 User Manual

MD1250
TACTICAL INFLATABLE SIDE POUCH LP
DO NOT REMOVE PRIOR TO SALE
Warning: This document is for the use of licensed users only.
No part of this document may be reproduced, transmitted, or transcribed in any form or by any means without the express permission of Mustang Survival Corp.
While every effort possible has been made to ensure technical accuracy, information within this document is subject to change without notice.
i
Tactical Inflatable Side Pouch LP Owners Manual
CONTENTS
Introduction ...................................................................................................1
Product Familiarization and Readiness .......................................................2
Readiness Checklist ......................................................................... 3
Wearing the LP ..............................................................................................3
Using an LE Belt .............................................................................. 3
Using Integrated PALS Webbing and a MOLLE Vest .................... 3
Inflating the LP ..............................................................................................4
Manual Inflation ............................................................................. 4
Auto-Inflation .................................................................................4
Oral Inflation ..................................................................................4
Donning the Inflated LP ............................................................................... 5
Converting the LP .........................................................................................5
Reversing the Conversion ............................................................... 5
Deflating the LP ............................................................................................5
Re-arming the LP ...........................................................................................6
Repacking the LP ...........................................................................................7
Gas Removal from the Inflation Cell ............................................. 7
Folding the Inflation Cell ............................................................... 8
Resetting and Closing the Zippers ................................................. 8
Final Packing ................................................................................... 9
Maintaining the LP .......................................................................................9
Prior to Use .....................................................................................9
General Tests and Inspections ........................................................9
Testing for Leaks ...........................................................................10
Testing the Oral Inflation Valve ................................................... 10
Testing the Manual Inflator .........................................................10
Testing the Automatic Inflator ....................................................11
Cleaning and Storing the LP ......................................................................11
Accessories ................................................................................................... 12
Glossary ........................................................................................................ 12
Tactical Inflatable Side Pouch LP Owners Manual
ii
INTRODUCTION
This manual provides instructions and guidelines for safely using and maintaining Mustang Survival MD1250 Tactical Inflatable Side Pouch Life Preservers (LPs).
The MD1250 LP provides flotation capability with minimum bulk or interference using separate, independently operated left and right LPs.
The MD1250 LP has been designed specifically for easy integration with law enforcement (LE) belts, and body armor and tactical vests, including integrated Pouch Attachment Ladder System (PALS) webbing and Modular Lightweight Load-carrying Equipment (MOLLE) vests.
The MD1250 LP inflates automatically on submersion using a manual/ automatic hydrostatic inflator that significantly reduces the potential for accidental inflation due to humidity, sea spray, or wet storage.
When the hydrostatic inflator is submerged in more than four inches in water the water inlet valve opens letting water contact the water-sensitive element. The water-sensitive element releases a stainless steel coil spring that drives a needle into the end of the CO allowing CO
Each MD1250 LP can be inflated manually by pulling the beaded manual inflation handle. The LP may also be converted to manual-only operation with the included automatic/manual conversion cap.
Backup or top-up manual inflation or buoyancy reduction can be accomplished using the oral inflator tube.
In-water performance tests with the MD1250 LPs attached to a typical body armor vest demonstrate the ability of the LPs to provide effective flotation and buoyancy.
Due to variances in local configuration, full gear in-water testing is strongly recommended to validate performance.
When worn, used, and serviced according to the instructions in this manual, Mustang Survival MD1250 Tactical Inflatable Side Pouch LPs can greatly increase a user's chance of survival in the water.
to fill the inflation cell.
2
cylinder, puncturing it and
2
1
Tactical Inflatable Side Pouch LP Owners Manual
4
1
2
3
2
3
4
1
1
3
2
4
Status Indicator
Hydrostatic Water Inlet Valve
Manual Ination Lanyard
Beaded Manual Ination Handle
Tabs
Black Locking Ring
Expiry Date
PRODUCT FAMILIARIZATION AND READINESS
The MD1250 Tactical Inflatable Side Pouch LPs are used in right/left pairs, and can be attached to an LE belt, or integrated PALS webbing and MOLLE vest. Right-hand LPs have the letter R on the attachment webbing straps (Figure 2); left-hand LPs have the letter L.
Figure 1 shows the front of a right-hand LP, locating the upper zipper (1), the elastic storage pocket (2), the automatic/manual conversion cap and lanyard (3) stowed in the elastic pocket, and the manual/automatic hydrostatic inflator (4).
Figure 2 shows the back of a right-hand LP, Velcro® tab (1), the two attachment webbing straps (2), the locking pull-the-dot snaps (3), and the beaded manual inflation handle (4).
Figure 3 shows the open LP, the unfolded inflation cell with printed folding guidelines (1), the oral inflation tube (2), the Inspection Record tag (3), and the Velcro® side attachment straps (4).
To become more familiar with the LP and its component parts:
1. Open the zippers completely, unfold the inflation cell, and place the LP on a clean, flat surface with the hydrostatic inflator face down (Figure 3).
2. Check and ensure the ring beneath the oral inflator tube mouthpiece is turned counterclockwise and the mouthpiece locked (Figure 4).
3. Turn the LP over and visually inspect the status indicator on the hydrostatic inflator (Figure 5). Green indicates that the inflator is armed and ready for use. Red indicates that the inflator has been fired and must be replaced – see Re-arming the LP.
4. Visually inspect the expiry date on the hydrostatic inflator (Figure 5). If the expiry date has passed, replace the inflator – see Re-arming the LP.
5. Repack the LP – see Repacking the LP.
Tactical Inflatable Side Pouch LP Owners Manual
Figure 1
Figure 4
Figure 2
Figure 5
Figure 3
2
Loading...
+ 11 hidden pages