Murphy WIR-97020B User Manual

WIR-97020B page 1 of 2
Typical Wiring Tech Sheet for Magnetic Switches and TATTLETALE®Annunciators
WIR-97020B
Revised 10-06
(00-02-0257)
Typical Wiring Diagram with 117/117PH Magnetic Switch
Typical Wiring Diagram with MS2100 TATTLETALE
®
20P
Pressure
Distributor
Fuel Valve
Rack Pull Solenoid
(RP2300 Series shown)
Ignition coil
20T
Temperature
PB128S Stop Switch
Energized
to Run
C
117/117PH
S
B
+
Ammeter
BAT
ST
IGN
ACC
Start Switch
Hourmeter
+
+
Voltmeter
_
_
_
S
B
Starter
_
+
Battery
B
+
GRDSIG
Tachometer
To Magnetic Sensor, Alternator “Tach” Terminal, or Signal Generator
B
+
Exciter
Alternator
20P
Pressure
MS2100MS2100
Typical Power
Adaptor
GAAS
Ignition Generator
“Kill”
Wire
1
4
5
Spark Plugs
Ignition Coils
6 2 3
16 2 3
4
5
20T
Temperature
WIR-97020B page 2 of 2
Typical Wiring Diagram with 760A and 761APH
Typical Wiring with 518PH TATTLETALE
®
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819 Rosenberg, Texas 77471 USA Phone: 281.633.4500 Fax: 281.633.4588 E-mail: sales@fwmurphy.com Web site: www.fwmurphy.com
FRANK W. MURPHY, LTD
Church Rd Laverstock Salisbury SP1 1QZ UK Phone: +44 1722 410055 Fax: +44 1722 410088 E-mail: sales@fwmurphy.co.uk Web site: www.fwmurphy.co.uk
COMPUTRONIC CONTROLS, LTD
41 - 43 Railway Terrace Nechells Birmingham B7 5NG UK Phone: +44 121 327 8500 Fax: +44 121 327 8501 E-mail: info@computroniccontrols.com Web site: www.computroniccontrols.com
FW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD
77 23rd Street Hangzhou Economic & Technological Development Area Hangzhou, Zhejiang, 310018, China Phone: +86 571 8788 6060 Fax: +86 571 8684 8878
FW MURPHY
P.O. Box 470248 Tulsa, Oklahoma 74147 USA +1.918.317.4100 Fax: +1.918.317.4266 E-mail: sales@fwmurphy.com
INDUSTRIAL PANEL DIVISION
Fax: 918.317.4124 E-mail: ipdsales@fwmurphy.com
MURPHY POWER IGNITION
Web site: www.murphy-pi.com
www.fwmurphy.com
Printed in U.S.A.
518PH
20T-F
Temperature
Energized
to Run
G NORNC
**
SW1 SW2
Jumper
B
*
Start Switch
Distributor
Fuel Valve
20P-F
Pressure
PB128S Stop Switch
Ignition coil
Ammeter
BAT
ST
IGN
ACC
CLOSEDLOOP™ Wiring
Hourmeter
_
+
_
+
Voltmeter
_
+
S
B
Starter
_
+
Battery
*
B
+
GRDSIG
Tachometer
To Magnetic Sensor, Alternator “Tach” Terminal, or Signal Generator
B
+
Exciter
Alternator
Rack Pull Solenoid (RP2300 Series shown)
*
Jumper is to be removed when connecting a CLOSEDLOOP™ circuit.
**
Normally Opened terminal is available on the 518APH & 518E models.
GNONC BS
R
760A/761APH
TD
+
Ammeter
BAT
ST
IGN
ACC
Start Switch
Hourmeter
Voltmeter
_
Distributor
Flyback
Diode
Rack Pull  Solenoid (RP2300  Series shown)
Fuel
Valve
20P
Pressure
Temperature
PB128S Stop Switch
Flyback
Flyback
20T
Ignition  Coil
Diode
Diode
NOTE 1
Normally Open
Relay with 
Flyback Diode
Energized
to Run
NOTE 1: With terminal “G” grounded, the time delay operates only on start; after the initial time delay, the shut-down circuit is operated immediately when SWICHGAGE With terminal “G” not grounded, the time delay operates both on start and stop.
+
+
Starter
Tachometer
B
_
_
+
Battery
S
B
+
GRDSIG
To Magnetic Sensor, Alternator “Tach” Terminal, or Signal Generator
_
B
Exciter
Alternator
®
contact operates.
+
Loading...