Murphy VS2, VS2C, VS2EX, VS2EXRB, VS2EXR Installation Instructions Manual

...
Shock/Vibration Control Switches Installation Instructions
Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94
GENERAL INFORMATION
Please read the following instructions before installing. A visual inspection of this product for damage during shipping is recommended before mounting. It is your responsibility to have a qualified person install the unit, and make sure installation conforms with NEC and local codes.
Model VS2EX
LISTED
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
Disconnect all electrical power to the machine.
Make sure the machine cannot operate during installation.
Follow all safety warnings of the machine manufacturer.
Read and follow all installation instructions.
VS-7037N
Revised 04-05
Section 20
(00-02-0185)
R
VS-7037N page 1 of 8
Description
The Murphy shock and vibration switches are available in a variety of models for applications on machinery or equipment where excessive vibration or shock can damage the equipment or otherwise poses a threat to safe operation. A set of contacts is held in a latched position through a mechanical latch and magnet mechanism. As the level of vibration or shock increases an inertia mass exerts force against the latch arm and forces it away from the magnetic latch causing the latch arm to operate the contacts. Sensitivity is obtained by adjusting the amount of the air gap between the magnet and the latch arm plate.
Applications include all types of rotating or reciprocating machinery such as cooling fans, engines, pumps, compressors, pump jacks, etc.
Models
VS2: Base mount; non hazardous locations. VS2C: C-clamp mount; non hazardous locations. VS2EX: Explosion-proof; Class I, Div. 1,
Groups C and D.
VS2EXR: Explosion-proof with remote reset. VS2EXRB: Explosion-proof; Class I, Div. 1, Group B; with
remote reset.
VS94: Base mount; non hazardous locations, NEMA 4X/IP66.
Remote Reset Feature (VS2EXR, VS2EXRB and VS94 only)
Includes built-in electric solenoid which allows reset of tripped unit from a remote location. Standard on VS2EXR and VS2EXRB. Optional on VS94 (options listed below).
-R15: Remote reset for 115 VAC
-R24: Remote reset for 24 VDC
Time Delay Option (VS94 only)
Overrides trip operation on start-up. For VS94 series models, the delay time is field-adjustable from 5 seconds up to 6-1/2 minutes with a 20­turn potentiometer (15 seconds per turn approximately). Options listed below:
-T15: Time delay for 115 VAC
-T24: Time delay for 24 VDC
Space Heater Options (VS94 only)
This optional space heater board prevents moisture from condensing inside the VS94 Series case. Options listed below:
-H15: Space heater for 115 VAC
-H24: Space heater for 24 VDC
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
WARNING
VS-7037N page 2 of 8
DIMENSIONS
3 in.
(76 mm)
4-3/4 in.
(121 mm)
2-1/4 in. (57 mm)
5-1/8 in.
(130 mm)
Mounting Holes
Slotted Sensitivity Adjustment
Reset Push Button
4-19/32 in.
(116 mm)
Plug
1/4 x 1/2 in.
(6 mm x 13 mm)
Slot 2 places
3 in.
(76 mm)
4-3/4 in.
(121 mm)
Slotted Sensitivity Adjustment
5-7/16 in. (138 mm)
Reset Push Button
Weatherproof Strain Relief Bushing
C-Clamp
27/32 in. (21 mm)
1/2 NPT 
Conduit
5-5/8 in.
(143 mm)
3 in.
(76 mm)
Mounting Holes
Reset Push Button
Slotted Sensitivity Adjustment
5-1/4 in.
(133 mm)
Mounting Holes
4-7/8 in.
(124 mm)
6-3/8 in.
(162 mm)
3/8 in. (10 mm) 4 places
1-3/4 in. (44 mm)
10-5/8 in.
(270 mm)
6 in.
(152 mm)
4-1/2 in.
(114 mm)
Mounting Centers
1/2 NPT
Conduit
9-1/8 in.
(232 mm)
Mounting Centers
10-3/16 in.
(259 mm)
8-5/8 in.
(219 mm)
2-1/2 in. (64 mm)
VS2
VS2C
VS2EX and VS2EXR
VS2EXRB
7-9/64 in. (181 mm)
4 in.
(102 mm)
6-1/2 in.
(165 mm)
6-29/32 in.
(176 mm)
Manual Reset Push-button
Mounting slot 5/16 x 9/16 in. (8 x 14 mm) 4-places.
6-1/2 in.
(165 mm)
4-5/8 in.
(118 mm)
1-5/8 in. (41 mm)
4 in.
(102 mm)
3/4 NPT conduit fitting 
VS94
VS-7037N page 3 of 8
SPECIFICATIONS
VS2 and VS2C
Case: Weatherproof (equal to NEMA 3R) suitable for non-hazardous areas.
VS2: Base mount VS2C: C-clamp mount. Includes 45 feet (13.7 meters), 2-conductor 16
AWG, 30 strands/0.25 mm strand dia. (1.5 mm2) cable, and five cable hold down clamps.
Contacts: SPDT double make leaf contacts, 5A @ 480 VAC.
Range adjustment: 0 - 7 G’s; 0 - 100 Hz /0.100 in. displacement.
VS2EX
Case: Explosion-proof and weatherproof aluminum alloy housing;
meets NEMA 7/IP50 specifications; Class I, Division 1, Groups C & D; UL and CSA listed.* VS2EX: base mount.
Snap-switches: 2-SPDT snap-switches; 5A @ 480 VAC;*
2A resistive, 1A inductive, up to 30 VDC.
Range adjustment: 0 - 7 G’s; 0 - 100 Hz /0.100 in. displacement.
Normal Operating Temperature: -40 to 140°F (-40 to 60°C).
VS2EXR
Case: Same as VS2EX.
Snap-switch: 1-SPDT snap-switch and reset coil; 5A @ 480 VAC;*2A
resistive, 1A inductive, up to 30 VDC.
Remote Reset (optional):
Option Operating Current
-R15: 350 mA @ 115 VAC
-R24: 350 mA @ 24 VDC
Range adjustment: 0 - 7 G’s; 0 - 100 Hz /0.100 in. displacement.
Normal Operating Temperature: -40 to 140°F (-40 to 60°C).
VS2EXRB
Case: Explosion-proof aluminum alloy housing; rated Class I,
Division 1, Group B hazardous areas.
Snap-switch: 1-SPDT snap-switch with reset coil (option available for
additional SPDT switch); 5A @ 480 VAC; 2A resistive, 1A inductive, up to 30 VDC.
Remote Reset:
Option Operating Current
-R15: 350 mA @ 115 VAC
-R24: 350 mA @ 24 VDC
Range adjustment: 0 - 7 G’s; 0 - 100 Hz /0.100 in. displacement.
VS94
Case: Polyester fiberglass reinforced; NEMA type 4 and 4X; IP66; CSA
types 4 and 12.
Conduit Fitting: 3/4 NPT conduit fitting connection.
Normal Operating Ambient Temperature:
0 to 140°F (-18 to 60°C).
Snap-switches: 2-SPDT snap acting switches; 5A @ 480 VAC; 2A
resistive, 1A inductive, up to 30 VDC.
Range adjustment: 0 - 7 G’s; 0 - 100 Hz /0.100 in. displacement.
Heater (optional):
Option Operating Current
H15 .023 A @ 115 VAC H24 .12 A @ 24 VDC
Remote Reset (optional):
Option Operating Current
R15 .17 A @ 115 VAC R24 .36 A @ 24 VDC
Time Delay (optional):
Option Operating Current Standby Current
T15 .360 A @ 115 VAC .01 A @ 115 VAC T24 1.15 A @ 24 VDC .01 A @ 24 VDC
Time Delay/Remote Reset: Adjustable 20-turn potentiometer from
5 seconds to 6-1/2 minutes (15 seconds per turn approximately).
*CSA and UL listed with 480 VAC rating.
The VS2 and VS94 series shock switches are sensitive to shock and vibration in all three planes of motion - up/down, front/back and side/side. Front/back is the most sensitive (The reset pushbutton is located on the “front” of the unit). For maximum sensitivity mount the unit so that the front faces into the direction of rotation of the machine. (See Dimensions on page 2 for sensitivity adjustment location).
The VS2 and VS94 Series must be firmly attached/mounted to the machine so that all mounting surfaces are in rigid contact with the mounting surface of the machine. For best results, mount the instrument in-line with the direction of rotating shafts and/or near bearings. In other words, the reset push button should be mounted pointing into the direction of shaft rotation (see page 5). It may be necessary to provide a mounting plate or bracket to attach the VS2 and VS94 Series to the machine. The mounting bracket should be thick enough to prevent induced acceleration/vibration upon the VS2 or VS94 Series. Typically 1/2 in. (13mm) thick plate is sufficient. See illustrations on page 5 for typical mounting locations.
CAUTION:
A dust boot is provided on the reset pushbutton for all series to prevent moisture or dust intrusion. The sensitivity adjustment for model VS2EX is not sealed; therefore, mounting
orientation should be on a horizontal plane or with the sensitivity adjustment pointing down. Sensitivity adjustment for model VS2 is covered by a plug. The plug must be in place and tight to prevent moisture or dust intrusion.
C-Clamp Installation (VS2C model only)
A C-Clamp is supplied with the VS2C model only. The C-Clamp is shipped installed on the VS2C but must be installed on the VS2EX and VS2EXR switches.
1. The C-Clamp (B) will already be installed on
a 1/4 in. (6 mm) thick steel mounting plate (A). Bolt the VS2 switch to the mounting plate as illustrated — with four 5/16 in. bolts, nuts, and washers.
2. The mounting location should provide
convenient access to the TATTLETALE
®
push button (C).
3. The hardened set screw and nuts (D) are used to
tighten the switch to an I-Beam or cross member such as a Sampson post of an oilwell pumpjack.
WARNING: STOP THE MACHINE AND DISCONNECT ALL ELECTRICAL POWER BEFORE BEGINNING INSTALLATION.
INSTALLATION
Continued on next page.
A
B
C
D
All Models
1. Firmly secure the unit to the equipment using the base foot mount or
C-Clamp if applicable. See C-Clamp Installation page 3.
For oilwell pumpjacks attach the VS2 and VS94 Series to the Sampson
post or walking beam. See Typical Mounting Locations page 5.
2. Make the necessary electrical connections to the vibration switch. See
Internal Switches, page 6 for electrical terminal locations and page 7 for typical wiring diagrams. DO NOT EXCEED VOLTAGE OR CURRENT RATINGS OF THE CONTACTS. Follow appropriate electrical codes/methods when making electrical connections. Be sure that the run of electrical cable is secured to the machine and is well insulated from electrical shorting. Use of conduit is recommended.
NOTE: If the electrical cable crosses a pivot point such as at the pivot of the walking beam, be sure to allow enough slack in the cable so that no stress is placed on the cable when the beam moves.
If conduit is not used for the entire length of wiring, conduit should be used from the electrical supply box to a height above ground level that prevents damage to the exposed cable from the elements, rodents, etc. or as otherwise required by applicable electrical codes. If conduit is not attached directly to the VS2 and VS94 Series switch, use a strain relief bushing and a weatherproof cap on the exposed end of the conduit. A “drip loop” should be provided in the cable to prevent moisture from draining down the cable into the conduit should the weathercap fail.
Sensitivity Adjustment
All models of the VS2 and VS94 Series cover a wide range of sensitivity. Each model is adjusted to the specific piece of machinery on which it is installed. After the switch has been installed in a satisfactory location (see page 5) the sensitivity adjustment will be increased or decreased so that the switch does not trip during start-up or under normal operating conditions. This is typically done as follows:
1. REPLACE ALL COVERS, LIDS, AND ELECTRICAL ENCLOSURES.
2. Press the reset push button to engage the magnetic latch. To be sure the
magnetic latch has engaged, observe latch through the window on the VS2 and VS2C (see DETAIL “A”). On the VS2EX, VS94 series the reset button will remain depressed meaning the magnetic latch has engaged.
3. Start the machine.
4. If the instrument trips on start-up,
allow the machine to stop. Turn the sensitivity adjustment 1/4 turn clockwise, (adjustment for VS94 and VS2EXRB models is located within the box, see DETAIL “B”).
Depress the reset button and restart the machine. Repeat this process until the unit does not trip on start-up.
5. If the instrument does NOT trip on start-
up, stop the machine. Turn the sensitivity adjustment 1/4 turn counter-clockwise. Repeat the start-up/stop process until the instrument trips on start-up. Turn the sensitivity adjustment 1/4 turn clockwise (less sensitive). Restart the machine to verify that the instrument will not trip on start-up.
6. Verify that the unit will trip when abnormal shock/vibration exists.
VS94 Time Delay Adjustment
1. Apply power to the time delay circuit. (see
page 7 for time delay circuit). The time delay function will be initiated.
2. Time the length of the delay with a watch. Let time delay expire. After it
expires, the override circuit will de-energize the solenoid, allowing the latch arm to trip. A clicking noise is heard.
3. TURN THE POWER OFF TO RESET THE TIME DELAY CIRCUIT.
NOTE: Allow 30 seconds bleed-time between turning the power “OFF” and “ON”.
4. Locate the time adjustment pot (DETAIL “C”).
The time is factory-set at the lowest setting (5 seconds approximately). To increase time, rotate the 20-turn pot clockwise as needed (15 seconds per turn approximately).
5. Repeat the above steps as necessary to
obtain desired time delay.
NOTE: An external time delay can be used with the remote reset feature of the VS2EXR series to provide a remote reset and override of the trip operation on start-up. Time delay must automatically disconnect after equipment start-up.
VS-7037N page 4 of 8
INSTALLATION
Continued
WARNING: STOP THE MACHINE AND DISCONNECT ALL ELECTRICAL POWER BEFORE BEGINNING INSTALLATION.
DETAIL “A”
Sensitivity
Adjustment
Reset Push button
DETAIL “C”
Turn to increase
Pot
Turn to decrease
WARNING: MAKE THE AREA NON-HAZARDOUS BEFORE
OPENING THE EXPLOSION-PROOF (-EX) ENCLOSURES.
WARNING: REMOVE ALL POWER BEFORE OPENING
THE ENCLOSURE. IT IS YOUR RESPONSIBILITY TO HAVE A QUALIFIED PERSON PERFORM ADJUSTMENTS, AND MAKE
SURE IT CONFORMS WITH NEC AND LOCAL CODES. DO NOT ADJUST SENSITIVITY WHILE THE MACHINE IS RUNNING. STAND CLEAR OF THE MACHINE AT ALL TIMES WHEN IT IS OPERATING.
WARNING: REMOVE ALL POWER BEFORE OPENING
ACCESS DOOR. IT IS YOUR RESPONSIBILITY TO HAVE A QUALIFIED PERSON ADJUST THE UNIT, AND MAKE SURE IT CONFORMS WITH NEC AND LOCAL CODES.
DETAIL “B”
Less
Sensitive
Sensitivity adjustment
More Sensitive
VS-7037N page 5 of 8
TYPICAL MOUNTING LOCATIONS
Engine Compressor
Turbine Centrifugal Compressor
Engine and Vertical Shaft Pump
“Y” Type Reciprocating Compressor
Generator Sets
Cooling Tower Fan or
Heat Exchanger
Pumping Unit
2-Throw Balance-Opposed Compressor
NOTE: If installing on
cylinders, 2 vibration/shock switches are recommended­1 for each cylinder.
Reset
Reset
Reset
Reset
Reset
These are typical mounting locations for best operation. Other mountings are possible. See
Installation
section on page 3.
NOTE:
Reset
Reset
Reset
Reset
VS-7037N page 6 of 8
INTERNAL SWITCHES
VS2 and VS2C VS2EXR
NO1 NC COM NO2
SPDT Switch Terminals
Sensitivity Adjustment
Remote Reset Terminal
Sensitivity Adjustment
NC NO COM
Ground Terminal
SPDT Snap-Switch
VS2EX
SPDT Snap-Switch
SPDT Snap-Switch
NC NO COM
NC NO COM
Sensitivity Adjustment
Ground Terminal
SPDT Snap-Switch
VS94
VS2EXB and VS2EXRB
NC NO COM
SPDT Snap-Switch
Time Delay and/or Remote Reset Terminal (Optional)
NC NO COM
Remote Reset Terminal
Sensitivity Adjustment
Ground Terminal
Optional SPDT Snap-Switch (VS2EXRB only)
SPDT Snap-Switch
NC NO COM
NC NO COM
Ground Terminal
Sensitivity Adjustment
Heater Board Terminal (Optional)
VS-7037N page 7 of 8
WARNING: REMOVE POWER BEFORE OPENING THE UNIT (ACCESS DOOR). STOP THE MACHINE AND DISCONNECT ALL
ELECTRICAL POWER BEFORE BEGINNING THE WIRING OPERATION. IT IS YOUR RESPONSIBILITY TO HAVE A QUALIFIED PERSON INSTALL AND WIRE THE UNIT, AND MAKE SURE IT CONFORMS WITH NEC AND APPLICABLE CODES.
ELECTRICAL
Typical Wiring Diagram for Single or Dual CD Ignition
VS2 and VS2C
Resistor
SPDT Switch
COM
To good engine ground
CD Ignition
2
Contacts shown in the RESET position.
(100 , 3 Watt)
CD Ignition
1
VS2EXR and VS2EXRB
Typical Wiring Diagram for Single or Dual CD Ignitions
SPDT Switch
(Optional 2-SPDT [DPDT])
Contacts shown in the
RESET position
N.C.N.O.
N.C.N.O.
Momentary Push Button
115 VAC or
Voltage
24 VDC (
is specified when ordered).
Remote Reset
Typical Wiring Diagram for Single or Dual CD Ignitions
VS2EX
SPDT Switch
(Optional 2-SPDT [DPDT])
Contacts shown in the
RESET position
NO2NCNO1
CD Ignition
2
CD Ignition
1
Resistor
(100 , 3 Watt)
N.C.N.O.
N.C.N.O.
COM
COM
To good engine ground
To good engine ground
VS94
Typical Wiring Diagram for Single or Dual CD Ignitions
2-SPDT
Switches (DPDT)
Contacts shown in the
RESET position
N.C.N.O.
N.C.N.O.
COM
COM
To good engine ground
COM
COM
To good engine ground
Additional Switch Optional on VS2EXRB only
Momentary Contact for Remote Reset only
Maintained Contact for Time Delay
115 VAC or 24 VDC
Time Delay or
Remote Reset
(Optional)
115 VAC or 24 VDC
Time
Delay
*
*
CD Ignition
2
CD Ignition
Resistor
(100 , 3 Watt)
1
VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94
Typical Wiring Diagram for Electric Motors
NOTE: Terminal N.O. is terminal NO1 on models VS2 and VS2C.
L1 L2 L3
MOTOR
Switch Terminals
N.O.
(see Note)
Push-button Station
HC
N.C.
Hand Off Automatic Selector
HC
To good engine ground
Contacts shown in the RESET position
COM
A
H
1
Heater Board (Optional)
Resistor
(100 , 3 Watt)
To good engine ground
*
Voltage is specified
when ordered.
CD Ignition
VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94
Typical Wiring Diagram for Distributor Ignition or Diesel
NOTE: Terminal N.O. is terminal NO1 on models VS2 and VS2C.
Diesel Fuel
Shutoff Valve
Ignition Coil
Switch Terminals
N.O.
(see Note)
Distributor
N.C.
Contacts shown in the RESET position
COM
Ignition
Switch
Ammeter
Battery
CD Ignition
2
VS-7037N page 8 of 8
SERVICE PARTS
PART NO. DESCRIPTION
VS2
20000030 Movement assembly 20000031 Glass and gasket assembly 20000032 Reset push button assembly
VS2C
20000030 Movement assembly 20000031 Glass and gasket assembly 20000032 Reset push button assembly 20050021 Mounting clamp 20000185 VS2C 5-clamp hardware package assembly. 20050465 2-Conductor electrical cable, 45 feet (13.7 meters)
VS2EX
20010091 Movement assembly 20050087 Cover 00000309 Cover gasket 20010090 Snap-switch and insulator kit (1 switch per kit)
prior to September 1, 1995.*
20000288 Snap-switch and insulator kit (1 switch per kit) for models
manufactured on September 1, 1995 or later.*
20000289 C-clamp conversion mounting kit
VS2EXR
20000262 Movement assembly 20050087 Cover 00000309 Cover gasket 20010090 Snap-switch and insulator kit (1 switch per kit)
prior to September 1, 1995.*
20000288 Snap-switch and insulator kit (1 switch per kit) for models
manufactured on September 1, 1995 or later.*
20000049 Reset solenoid assembly (115 VAC) 20000234 Reset solenoid assembly (24 VDC) 20000289 C-clamp conversion mounting kit
PART NO. DESCRIPTION
VS2EXRB
20010090 Snap-switch and insulator kit (1 switch per kit)
prior to September 1, 1995.*
20000288 Snap-switch and insulator kit (1 switch per kit) for models
manufactured on September 1, 1995 or later.*
20000057 Inside snap-switch and insulator kit (1 switch per kit) for
model VS2EXRB-D prior to September 1, 1995.*
20000058 Outside snap-switch and insulator kit (1 switch per kit) for
model VS2EXRB-D prior to September 1, 1995.*
20000287 Outside snap-switch and insulator kit (1 switch per kit) for model
VS2EXRB-D manufactured on September 1, 1995 or later.*
20000290 Inside snap-switch and insulator kit (1 switch per kit) for model
VS2EXRB-D manufactured on September 1, 1995 or later.*
20050077 Adjustment shaft 20000262 Movement assembly 20000049 Reset solenoid assembly (115 VAC) 20000234 Reset solenoid assembly (24 VDC)
VS94 Series
25050506 Dust boot 00000232 Conduit fitting 20010090 Snap-switch and insulator kit (1 switch per assembly)
prior to September 1, 1995.**
20000288 Snap-switch and insulator kit (1 switch per assembly)
for models manufactured on September 1, 1995 or later.***
* If no date code is found, refer to the old switch. Models with date 0895 and before use old switch.
Dated 0995 after, use straight snap-switch arm, no rollers. ** Models dated Q1 thru Q8 (formed snap-switch arm and rollers). ***Models date coded Q9 thru Q12 and R1 thru R12 (straight snap-switch arm, no rollers).
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588 e-mail sales@fwmurphy.com
INDUSTRIAL PANEL DIVISION
P.O. Box 470248 Tulsa, Oklahoma 74147 USA +1 918 317 4100 fax +1 918 317 4266 e-mail sales@fwmurphy.com
FRANK W. MURPHY, LTD.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mail sales@fwmurphy.co.uk www.fwmurphy.co.uk
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mail ventas@murphymex.com.mx www.murphymex.com.mx