Float/Boost Voltages:
Battery Type Float Volts (VDC) Boost Volts (VDC)
12V Lead Acid (6 cells) 13.6 14.1
www.fwmurphy.com
FW Murphy
P.O. Box 470248, Tulsa, OK 74147 phone:
+1 918.317.4100
fax: 918.317.4266 e-mail: sales@fwmurphy.com
Murphy Battery Chargers
0610058 07/06 Printed in U.S.A.
Sentry Model
Features:
CE and UL Approvals
Float Charging 5A at 12v
Auto boost operation
Electronic self-resetting output fuse protection
Temperature compensation
Charge fail relay output
Stainless steel enclosure
Power Supply
Nominal operating voltages: 120V units Permissible voltage variation: ± 6% of nominal Nominal operating frequency: 50-60Hz
DC Charge Output
Maximum current ADC: 5 Nominal voltage VDC: 12
Charge Fail Output
Relay type: volt free SPDT contacts; relay de-energized on fault Contact rating: 1A at 30V, DC (resistive load)
General
Operating temperature: +14 to +131°F (-10 to +55°C) EMC emission/immunity: EN 58801-2 / EN50082-2 Weight: 11.9 lbs. (5.6 Kg.)
Model Info:
BCES-12-5 12 volt, 5A, lead acid cells
Guardian Model
Features
CE and UL approvals
Heavy duty float charging: 10A at 12/24 VDC, 20A at 24 VDC
Short circuit and reverse polarity protection
Lead acid calibrations
Auto boost operation
Charge fail relay output
Under volts and over volts alarms
Temperature compensation
NFPA110 alarms
Power Supply
Nominal operating voltages: 120VAC ± 6% Permissible voltage variation: 120VAC ± 6% Nominal operating frequency: 50/60Hz
DC Charge Output
Maximum current ADC: 20/20 Nominal voltage VDC: 24/12
Charge Fail Output
Relay type: volt free SPDT contacts; relay de-energized on fault Contact rating: 1A at 30V, DC (resistive load)
General
Operating temperature: +14 to +100°F (-10 to +38°C) EMC emission/immunity: EN 58801-2 / EN50082-2 Weight: 17.9 lbs. (6.4 Kg.)
Fixing hole dimensions:
Width (between holes): 6.8” (173mm) Height (between holes): 10” (255mm) Fixing holes Ø=0.2” (6mm)
Model Info:
BCEG-12-10 12 volt, 10A, lead acid cells BCEG-24-10 24 volt, 10A, lead acid cells BCEG-24-20 24 volt, 20A, lead acid cells
Float/Boost Voltages:
Battery Type Float Volts (VDC) Boost Volts (VDC)
12V Lead Acid (6 cells) 13.6 14.1 24V Lead Acid (12 cells) 27.2 28.2
Under Volts Alarm 12.5 25 Over Volts Alarm 15.5 31 Delay on under volts 120 seconds
Normal Output VDC
12 24
FRONT SIDE
5.62 in. (143 mm)
11.25 in. (286 mm)
2.5 in.
(63.5 mm)
0.2 in.Ø (6 mm) 4-places
10.62 in. (270 mm)
4.5 in.
(114 mm)
FRONT SIDE
11 in. (280 mm)
11 in. (280 mm)
A
6.75 in. (171 mm)
C
0.2 in.Ø (6 mm) 4-places
10 in. (254 mm)
5 in.
(127 mm)
Loading...